SHARP IG-A10EU User Manual

Plasmacluster is trademark of Sharp Corporation.
Plasmacluster Ion Generator OPERATION MANUAL
IG-A10EU
Read and keep this manual carefully.
Bitte lesen Sie diese Anleitung und
bewahren Sie sie auf.
Veuillez lire et enregistrer ces instructions.
Lees en bewaar deze instructies.
Прочтите данное руководство и
сохраните его.
Plasmacluster-Ionen-Generator BEDIENUNGSANLEITUNG
Générateur d’ions Plasmacluster MODE D’EMPLOI
Plasmacluster Ion Generator BEDIENINGSHANDLEIDING
Ионный генератор Plasmacluster РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ENGLISH
DEUTSCH
FRANÇAIS
NEDERLAND
РУССКИЙ
SHARP CORPORATION
OSAKA, JAPAN
Printed in China TINS-A325KKRZ 09A-
ENGLISH
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
• WARNING
• CAUTIONS CONCERNING OPERATION
• INSTALLATION GUIDELINES
PARTS NAME
• FRONT
• BACK
INSTALLATION POSITION OPERATION CLEANING AND MAINTENANCE
• MAIN UNIT
• FILTER
...............................................................
......................................
........................................................
.................................................................................
...................................................................................
...........................................
......................................................................
.............................
...........................................................................
.................................................................................
...............
......................
PLASMACLUSTER ION GENERATING UNIT REPLACEMENT HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
SPECIFICATIONS TROUBLESHOOTING
............................................................
....................................................
....
....
E-2 E-2
E-2 E-2
E-3 E-3
E-3
E-4
E-4
E-5 E-5
E-5
E-6
E-7 E-8 E-8
ENGLISH
• While IG-A10EU can inactivate and eliminate suspended viruses and other contaminants, it cannot create a completely sterile environment. SHARP does not guarantee its ability to prevent microbial infection.
• To enable stable emission of high-density Plasmacluster ions, the Plasmacluster Ion Generating Unit mounted in IG-A10EU will need to be replaced periodically*
* Replacement is required approximately every 2 years (17,500 hours) when operated
24 hours a day. IG-A10EU will stop operating after about 26 months (19,000 hours) if the Plasmacluster Ion Generating Unit is not replaced.
Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please read this manual carefully before using Plasmacluster Ion Generator. After reading, keep the manual in a convenient location for future reference.
.
E-1
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electrical shock, fi re, or injury :
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet is loosened.
• Periodically remove dust from the plug.
• DO NOT insert fi ngers or foreign objects into the air intake or air outlet.
• Always hold the plug and never pull on the cord when removing the power plug.
Electrical shock and/or fi re from a short circuit may result.
• DO NOT remove the plug when your hands are wet.
• DO NOT use the unit near gas appliances or fi replaces.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Center or qualifi ed person in order to avoid a hazard.
• Be cautious when cleaning the unit.
Strong corrosive cleansers may damage the exterior.
• DO NOT use it in the areas where the unit may get wet.
• DO NOT use spray products near the unit. DO NOT use in the rooms, containing oil component, incense, cigarettes’ sparks, and chemical fumes.
• DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, in­cense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet, such as a bathroom.
• Only a Sharp Authorized Service Center should service this Plasmacluster Ion Generator.
Contact the nearest Service Center for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
CAUTIONS CONCERNING OPERATION:
• DO NOT block the air intake and/or air outlet.
• DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam.
• Always operate the main unit in an upright position.
• Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or cracked.
• Keep the main unit away from water.
INSTALLATION GUIDELINES:
• Place at least 2m away from equipment utilizing electric waves such as televisions or radios to avoid electrical interference when using the unit.
• Avoid using in locations where the unit is exposed to condensation or drastic temperature changes. Appropriate room temperature is between 0-35ºC.
• Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may crack as a result.
NOTE - Radio or TV Interference:
If this Plasmacluster Ion Generator may cause interference to radio or television reception, try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the unit and radio/TV receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
E-2
PARTS NAME
FRONT
DISPLAY
Unit Replacing
(See E-6)
Light
High
(red)
(blue)
Louvers
(See E-4)
Top Cover Cap
Screws
Air outlet
(blue)
Low
Button
Fan Speed Indicator
Filter (Air Intake)
BACK
Operation
Top Cover
Plasmacluster Ion Generating Unit
(See E-6,7)
Filter (Air Intake)
(See E-5)
Use a pointed object, e.g a pen tip, to press this button after replacing Plasmacluster Ion Generating Unit. Do not press it for any other purpose.
(This is to reset the Unit Replacing Light.)
ENGLISH
Power Cord
Plug
E-3
INSTALLATION POSITION
Place the main unit on a smooth,
DO NOT USE the below items near the unit.
stable surface in a room and insert the plug into an outlet.
DO NOT hold the louvers when carrying the unit.
silicone-containing products*
SPRAY
WAX
PESTICIDE
Installation Guidance.
Leave at least 15cm of clearance behind the Unit.
UPSIDE More than 1m
BACKSIDE More than 15cm
LEFT/RIGHT SIDE More than 20cm
* Hair care products, cosmetic products,
water proof sprays, polish glass cleaner, wipe and wax.
OPERATION
Press the operation button to directly turn on the power and select the preferred mode.
LOW
Release high-density Plasmacluster ions quietly.
Increase the volume of
HIGH
'OFF'
Plasmacluster ions to increase the purifying capacity.
Power 'OFF'.
Louvers
The air comes from direction, which is stamped on the louvers.
•When releasing ions to the entire room, put each louver in an opposite direction.
•When releasing ions to the point to deodorize the adhering odor on clothes, put both louvers in the same direction
E-4
.
CLEANING AND MAINTENANCE
WARNING: When cleaning the unit, be sure to fi rst unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
Main Unit
Every month or more often if necessary
Wipe with a dry soft cloth.
<For Stubborn Dirt>
Use water and a mild detergent. And then, wipe with a wet cloth. Make sure to dry out the main unit.
rt>
Filter
Every 2 weeks or more often if necessary
Gently remove dust from the filters by using a vacuum cleaner.
Filter
<For Stubborn Dirt>
Detach the filter and remove dust with using a vacuum cleaner.
ENGLISH
Filter
* The fi lter is not disposable item, often clean it.
E-5
PLASMACLUSTER ION GENERATING UNIT REPLACEMEN
T
In order to release Plasmacluster Ion stably, periodical Plasmacluster Ion Generating Unit replacement
is necessary. The Unit Replacing
Light will be ON as a reminder for replacement.
Elapsed Time
Beginning to use
approx. 2 years (approx. 17,500hours)
approx. 2 years and 2 months (approx.19,000hours)
Plasmacluster Ions are not released.
lighting (blue)
lighting (blue)
Display
ashing(red)
ashing faster
(red)
All light are ashing
Message
Suggest replacing
Stop working
Replace the
Plasmacluster Ion Generating Unit
Error*
* Usage environment affects the lifetime of the Plasmacluster Ion Generator. The Plasmacluster Ion Generator may stop working before estimated lifetime. In this case, press Operation button again and restart. If this does not help, replace with a new Plasmacluster Ion Generating Unit.
Replacement of Plasmacluster Ion Generating Unit
Plasmacluster Ion Generating Unit
Model Number
IZ-CA10E
<For Disposal>
Please dispose the used Plasmacluster Ion Generating Unit according to any local laws and regulations.
-materials-
• Case : Polystyrene
Unit : Polystyrene Terephthalate, Electric parts
E-6
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
* When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the
main unit, unplug the power cord, and never handle the plug with wet hands.
Remove the
1
LOUVERS.
Remove the TOP
2
COVER CAP.
Turn the 2 SCREWS
3
Lift up the TOP
4
COVER.
Replace the
5
Plasmacluster Ion Generating Unit.
ENGLISH
SCREWS
* See the manual of Plasmacluster Ion
Generating Unit for replacement.
E-7
SPECIFICATIONS
Model Power supply Power consumption (W) Airfl ow volume (m3/hour) Applicable fl oor surface area (m2)* Power cord (m) Outer dimensions (mm) Weight (kg)
*The target fl oor surface area for which an emitted airborne ion density of about 25,000 ions/cm3 can be measured at a point near the center of the room (at a height of about 1.2 m from the fl oor), during operation at the HIGH mode when the main unit is placed near a wall.
• The number of ions will vary according to the room conditions and the main unit operation mode.
(High) (High) 102
140 160 345 (W D H)
IG-A10EU
220-240V, 50/60Hz
14.0
(Low) 6.5 (Low) 72
10
1.8
2.5
TROUBLESHOOTING
Before calling for service, please review the TROUBLESHOOTING chart below,since the problem may not be Plasmacluster Ion Generator malfunctions.
Problem
The Plasmacluster Ion Generator does not work.
ashing faster (red)
ashing (red)
ashing (blue)
ashing (blue)
Make sure to put in the plug.
Approx. 2 years and 2 months (approx. 19,000 hours) has been passed. Replace with a new Plasmacluster Ion Generating Unit. See page E-6,7.
Plasmacluster Ions are not released. Press the Operation button and restart.
If all lights keep fl ashing, replace with new Plasmacluster Ion Generating Unit. See page E-6,7.
Dust may block the fi lter, clean the fi lter.
Failure Unplug and contact the store you purchased or Sharp Service Center.
WHAT TO DO
ashing (blue)
The discharged air has odor. The Plasmacluster Ion Generator releases a
A clicking or ticking sound comes from the unit while operating the Plasmacluster Ion Generator.
small trace of ozone which may produce odor. This is not harmful to health.
Loudness can be changed depending on a room humidity, but the effectiveness is the same. Relocate the Plasmacluster Ion Generator if necessary.
E-8
Attention: Your product is marked with this symbol. It means that used electrical and electronic products should not be mixed with general household waste. There is a separate collection system for these products.
A. Information on Disposal for Users (private households)
1. In the European Union
Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin!
Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. In some countries* your local retailer may also take back your old product free of charge if you purchase a similar new one.
*) Please contact your local authority for further details.
If your used electrical or electronic equipment has batteries or accumulators, please dispose of these separately beforehand according to local requirements.
By disposing of this product correctly you will help ensure that the waste undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling.
2. In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.
For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of
B
. Information on Disposal for Business Users.
www.swico.ch or www.sens.ch.
1. In the European Union
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.
For Spain: Please contact the established collection system or your local authority for take-back of your used products.
2. In other Countries outside the EU
If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.
ENGLISH
EN
DEUTSCH
INHALT
WICHTIGE SICHERHEITSHINWEISE
• WARNUNG
• VORSICHTSMAßNAHMEN FÜR DEN BETRIEB
• INSTALLATIONSANLEITUNG
TEILEBEZEICHNUNG
• VORDERSEITE
• RÜCKSEITE
AUFSTELLPOSITION BETRIEB REINIGUNG UND PFLEGE
• HAUPTGERÄT
• FILTER
..............................................................
.....................................
...........................................
...................................................................
........................................................................
....................................................
.............................................................................
..........................................
....................................................................
.................................................................................
...................
.............
G-2 G-2
G-2 G-2
G-3 G-3
G-3
G-4
G-4
G-5 G-5
G-5
AUSTAUSCH DER PLASMACLUSTER-IONEN GENERIERENDEN EINHEIT
........................................
G-6
SO TAUSCHEN SIE DIE PLASMACLUSTER-IONEN GENERIERENDE EINHEIT AUS
TECHNISCHE DATEN FEHLERSUCHE
...............................................................
....................................................
........................................
G-7 G-8 G-8
DEUTSCH
Der IG-A10EU kann zwar in der Luft schwebende Viren und andere Kontaminationen deaktivieren und eliminieren, jedoch keine vollständig sterile Umgebung herstellen. SHARP garantiert nicht dessen Eignung zur Verhütung mikrobiologischer Infektionen.
Um gleichbleibende Emission hoch-verdichteter Plasmacluster-Ionen zu ermöglichen, muss die im IG-A10EU eingebaute Plasmacluster­Ionen generierende Einheit regelmäßig ausgetauscht werden*.
*
Ersatz ist bei 24-Stunden-Betrieb am Tag etwa alle 2 Jahre (17 500 Stunden) erforderlich. Der IG-A10EU wird nach ca. 26 Monaten (19 000 Stunden) den Betrieb einstellen, wenn die Plasmacluster-Ionen generierende Einheit nicht ausgetauscht wird.
Wir danken Ihnen herzlich für den Kauf dieses SHARP Plasmacluster-Ionen­Generators. Bitte lesen Sie diese Bedienungsanleitung sorgfältig durch, bevor Sie den Plasmacluster-Ionen-Generator in Betrieb nehmen. Bewahren Sie die Bedienungsanleitung, nachdem Sie sie gelesen haben, an einem leicht zugänglichen Ort auf, damit Sie bei Bedarf nachschlagen können.
G-1
WICHTIGE SICHERHEITSHINWEISE
Bei der Verwendung elektrischer Geräte müssen grundlegende Vorsichtsmaßnahmen beachtet werden, einschließlich der Folgenden:
WARNUNG - Um das Risiko eines elektrischen Schlages, Brandes oder Verletzungen zu reduzieren:
• Lesen Sie alle Anweisungen vor Inbetriebnahme des Gerätes.
• Verwenden Sie ausschließlich eine Steckdose mit einer Spannung von 220-240 Volt.
• Nehmen Sie das Gerät NICHT in Betrieb, wenn das Netzkabel oder der Netzstecker beschädigt ist oder wenn der Anschluss an die Steckdose gelockert ist.
• Entfernen Sie regelmäßig Staub vom Stecker.
• Stecken Sie NIEMALS Ihre Finger oder Fremdkörper in den Lufteinlass oder -auslass.
Halten Sie das Netzkabel bei Abtrennen des Netzsteckers stets am Stecker selbst und niemals am Kabel fest. Anderenfalls kann es zu einem Kurzschluss und dadurch zu einem elektrischen Schlag und/oder Brand kommen.
• Ziehen Sie den Stecker NICHT mit feuchten Händen raus.
• Betreiben Sie das Gerät NICHT in der Nähe von Gasgeräten oder offenen Kaminen.
Falls das Netzkabel beschädigt ist, muss es durch den Hersteller, einen Kundendienst, ein durch Sharp autorisiertes
Kundendienst-Center oder durch einen qualifi zierten Techniker ausgetauscht werden, um Gefahren zu vermeiden.
• Seien Sie bei der Reinigung des Gerätes vorsichtig.
Stark ätzende Reinigungsmittel können das Gehäuse beschädigen.
• Betreiben Sie das Gerät NICHT in Bereichen, in denen es feucht werden könnte.
• Verwenden Sie KEINE Spray-Produkte in der Nähe des Gerätes.
• Betreiben Sie das Gerät NICHT in Räumen, in denen ölige Bestandteile, Weihrauch, Zigaretten­Funken und chemische Dämpfe vorhanden sind.
Nehmen Sie das Gerät NICHT in Betrieb, wenn Sie Insektenspray verwenden oder in Räumen, in denen ölige
Rückstände, Weihrauch, Funken von bennenden Zigaretten, chemische Dämpfe o.ä. in der Luft vorhanden sind. Dasselbe gilt für Räume, in denen das Gerät feucht werden könnte, wie zum Beispiel Badezimmer.
Die Servicearbeiten an diesem Plasmacluster-Ionen-Generator sollten ausschließlich durch ein
von Sharp autorisiertes Kundendienst-Center ausgeführt werden. Wenden Sie sich bei jeglichen Problemen, erforderlichen Einstellungen oder Reparaturen an ein Kundendienst-Center in Ihrer Nähe.
• Dieses Gerät darf nicht von Personen (einschließlich Kindern) verwendet werden, die über eingeschränkte körperliche, Sinnes- oder geistige Fähigkeiten verfügen, oder denen es an Erfahrung und Wissen fehlt, es sei denn, sie wurden von Personen, die für ihre Sicherheit verantwortlich sind, in die Benutzung des Gerätes eingewiesen und dabei beaufsichtigt.
• Kinder sollten beaufsichtigt werden, um sicher zu gehen, dass sie nicht mit dem Gerät spielen.
VORSICHTSMAßNAHMEN FÜR DEN BETRIEB:
• Verdecken Sie NICHT den Lufteinlass und/oder Luftauslass.
• Betreiben Sie das Gerät NICHT in der Nähe heißer Gegenstände, wie Öfen oder Heizgeräten, oder an Orten, an denen es mit heißem Dampf in Berührung kommen könnte.
• Betreiben Sie das Gerät stets in aufrecht stehender Position.
• Reinigen Sie das Gerät nur mit einem weichen Tuch, anderenfalls könnte die Oberfläche beschädigt werden oder es könnten sich Risse bilden.
• Halten Sie das Gerät von Wasser fern.
INSTALLATIONSANLEITUNG:
Plazieren Sie das Gerät in mindestens 2 Meter Entfernung zu anderen Geräten, die elektrische Strahlung aussenden, wie Fernseher oder Radiogeräte, um elektrische Störungen während des Betriebes des Gerätes zu vermeiden.
Vermeiden Sie eine Verwendung an Orten, an denen das Gerät Kondensation oder drastischen Temperaturschwankungen ausgesetzt ist. Die angemessene Raumtemperatur liegt zwischen 0 und 35°C.
• Vermeiden Sie Räumlichkeiten, in denen Fett oder öliger Rauch erzeugt wird, anderenfalls könnten sich Risse an der Oberfl äche des Hauptgerätes bilden.
HINWEIS - Störung des Radio- oder Fernsehempfangs:
Falls dieser Plasmacluster-Ionen-Generator Störungen des Radio- oder Fernsehempfangs verursacht, versuchen Sie, die Störung durch eine oder mehrere der folgenden Maßnahmen zu beheben:
• Richten Sie die Empfangsantenne anders aus oder stellen Sie sie an einem anderen Ort auf.
• Vergrößern Sie den Abstand zwischen dem Gerät und dem Radio/Fernsehgerät.
• Schließen Sie das Gerät an eine Steckdose an, die mit einem anderen Stromkreis verbunden ist, als die, an die das Radio/Fernsehgerät angeschlossen ist.
• Wenden Sie sich an Ihren Händler oder an einen erfahrenen Radio/Fernsehtechniker.
G-2
TEILEBEZEICHNUNG
VORDERSEITE
ANZEIGE
Lüftungsgitter
(Siehe G-4)
Geräteaustausch-
(Siehe G-6)
Leuchte
Hoch
(rot)
(blau)
Betriebstaste
Niedrig
(blau)
Lüftergeschwindigkeits­Anzeige
Filter (Lufteinlass)
RÜCKSEITE
Obere Abdeckkappe
Schrauben
Luftauslass
Obere Abdeckung
Plasmacluster­Ionen generierende Einheit
(Siehe G-6,7)
Filter (Lufteinlass)
(Siehe G-5)
DEUTSCH
Verwenden Sie ein spitzes Objekt, z.B. eine Kugelschreiberspitze, um diesen Knopf nach dem Austausch der Plasmacluster-Ionen generierenden Einheit einzudrücken. Drücken Sie den Knopf zu keinem anderen Zweck.
(Dies dient zum Zurücksetzen der Geräteaustausch-Leuchte).
Netzkabel
Netzstecker
G-3
AUFSTELLPOSITION
Plazieren Sie das Hauptgerät auf einer ebenen, stabilen Oberfl äche in einem Raum und stecken Sie den Netzstecker in eine Steckdose.
Halten Sie das Gerät beim Transport NICHT an den Lüftungsgittern.
Verwenden Sie die folgenden Gegenstände NICHT in der Nähe des Gerätes
Produkte, die Silikon enthalten*
SPRAY
WACHS
PESTIZIDE
Aufbauanleitung.
Lassen Sie mindestens 15 cm Abstand hinter dem Gerät.
OBERSEITE Mehr als 1 m
RÜCKSEITE Mehr als 15 cm
LINKE/RECHTE SEITE Mehr als 20 cm
* Haarpfl egeprodukte, Kosmetika,
Imprägnierspray, Glassreiniger, Wischmittel und Wachs.
BETRIEB
Drücken Sie die Betriebstaste, um den Strom direkt einzuschalten, und wählen Sie den gewünschten Modus.
NIEDRIG
Ruhige Abgabe hochdichter Plasmacluster Ionen.
Erhöhen der Menge der
HOCH
'OFF'
Plasmacluster Ionen, um die Reinigungskapazität zu erhöhen.
Ausschalten.
Lüftungsgitter
Die Luft kommt aus der " " Richtung, die auf den Lüftungsgittern aufgedruckt ist.
Wenn Sie Ionen in den gesamten Raum abgeben möchten, stellen Sie jedes Lüftungsgitter in die entgegengesetzte Richtung.
Wenn Sie Ionen abgeben möchten, um an Kleidung anhaftende Gerüche zu desodorieren, stellen Sie beide Lüftungsgitter in dieselbe Richtung.
G-4
REINIGUNG UND PFLEGE
WARNUNG: Wenn Sie das Gerät reinigen, überzeugen Sie sich zuerst, dass das Netzkabel herausgezogen ist, und berühren Sie den Stecker niemals mit feuchten Händen. Anderenfalls kann es zu elektrischem Schlag und/oder Verletzungen kommen.
Hauptgerät
Jeden Monat oder häufi ger, wenn erforderlich
Wischen Sie das Gerät mit einem trockenen, weichen Lappen ab.
<Bei hartnäckigen Flecken>
Verwenden Sie Wasser und ein mildes Reinigungsmittel. Danach mit einem feuchten Lappen abwischen. Vergewissern Sie sich, dass das Hauptgerät vollständig trocknet.
rt>
Filter
Alle 2 Wochen oder häufi ger, wenn erforderlich
Entfernen Sie den Staub sanft mit einem Staubsauger von den Filtern.
Filter
<Bei hartnäckiger Verschmutzung>
Nehmen Sie den Filter ab und entfernen Sie den Staub mit einem Staubsauger.
DEUTSCH
Filter
* Der Filter ist kein Wegwerfartikel, reinigen Sie ihn
daher häufi g.
G-5
AUSTAUSCH DER PLASMACLUSTER­IONEN GENERIERENDEN EINHEIT
Um gleichbleibend Plasmacluster-Ionen abzugeben, ist der regelmäßige Austausch der Plasmacluster-Ionen generierenden Einheit erforderlich. Das Geräteaustausch­Licht bleibt währenddessen AN, als Erinnerung an den Austausch.
Abgelaufene Zeit
Betriebsbeginn
Ca. 2 Jahre (ca. 17 500 Stunden)
Ca. 2 Jahre und 2 Monate (ca. 19 000 Stunden)
Plasmacluster­Ionen werden nicht abgegeben.
leuchtet (blau)
leuchtet (blau)
Anzeige
blinkt (rot)
blinkt schnell (rot)
Alle Lichter blinken
Meldung
Austausch empfohlen
Betrieb gestoppt
Tauschen Sie die
Plasmacluster-Ionen generierende Einheit aus
Fehler*
*
Die Nutzungsumgebung beeinträchtigt die Lebensdauer des Plasmacluster-Ionen-Generators. Der Plasmacluster-Ionen-Generator kann vor der erwarteten Lebensdauer den Betrieb einstellen.
Drücken Sie in diesem Fall erneut die Betriebstaste und starten Sie neu. Wenn das nicht hilft, ersetzen Sie die Plasmacluster-Ionen-Generator Einheit
durch eine neue Einheit Unit.
Austausch der Plasmacluster-Ionen generierenden Einheit
Plasmacluster-Ionen generierende Einheit
Modellnummer
IZ-CA10E
<Zur Entsorgung>
Bitte entsorgen Sie die gebrauchte Plasmacluster­Ionen generierende Einheit entsprechend den örtlichen Gesetzen und Bestimmungen.
-Materialien-
• Gehäuse: Polystyrol
Einheit: Polystyrol Terephthalat, Elektronische Teile
G-6
SO TAUSCHEN SIE DIE PLASMACLUSTER­IONEN GENERIERENDE EINHEIT AUS
* Wenn Sie die Plasmacluster-Ionen generierende Einheit austauschen, vergewissern
Sie sich bitte, dass Sie das Hauptgerät ausgeschaltet und das Netzkabel herausgezogen haben. Berühren Sie den Netzstecker niemals mit feuchten Händen.
Entfernen Sie die
1
LÜFTUNGSGITTER.
Entfernen Sie
2
die OBERE ABDECKKAPPE.
Lösen Sie die 2
3
SCHRAUBEN.
* Siehe Bedienungsanleitung zum
Austausch der Plasmacluster-Ionen generierenden Einheit.
G-7
Klappen Sie
4
die OBERE ABDECKUNG auf.
Tauschen Sie die
5
Plasmacluster­Ionen generierende Einheit aus.
SCHRAUBEN
DEUTSCH
TECHNISCHE DATEN
Modell Stromanschluss Stromverbrauch(W) Luftfl uss-Volumen (m3/Stunde) Maßgeblicher Bodenfl ächenbereich (m2)* Netzkabel (m) Abmessungen (mm) Gewicht (kg)
*
Der angestrebte Bodenflächenbereich, für den die an die Luft abgegebene Ionen-Dichte von ca. 25 000 Ionen/cm3 an einem Punkt nahe der Raummitte gemessen werden kann (bei einer Höhe von etwa 1,2m vom Boden aus), während das Hauptgerät in der Nähe einer Wand plaziert und im Modus HIGH betrieben wird.
Die Anzahl der Ionen wird den Raumbedingungen und dem Betriebsmodus des Hauptgerätes entsprechend variieren.
(Hoch) (Hoch) 102
140 160 345 (B T H)
IG-A10EU
220-240V, 50/60Hz
14,0
(Niedrig) 6,5 (Niedrig) 72
10
1,8
2,5
FEHLERSUCHE
Sehen Sie sich bitte die untenstehende Tabelle zur FEHLERSUCHE an, bevor Sie sich an den Kundendienst wenden, da es sich bei Problemen möglicherweise nicht um eine Fehlfunktion des Plasmacluster-Ionen-Generators handelt.
Problem
Der Plasmacluster-Ionen-Generator funktioniert nicht.
blinkt schnell (rot)
blinkt (rot)
blinkt (blau)
blinkt (blau)
Überprüfen Sie, ob der Netzstecker angeschlossen ist.
Es sind etwa 2 Jahre und 2 Monate (etwa 19000h) vergangen. Ersetzen Sie die Plasmacluster-Ionen generierende Einheit. Siehe Seite G-6,7
Es werden keine Plasmacluster-Ionen abgegeben. Drücken Sie die Betriebstaste und starten Sie neu.
Wenn alle Leuchten ständig blinken, ersetzen Sie die Plasmacluster-Ionen generierende Einheit. Siehe Seite G-6,7.
Staub könnte den Filter verstopfen, reinigen Sie den Filter.
Betriebsstörung Kontaktieren Sie den Händler bei dem das Gerät erworben wurde oder das Sharp Service Center.
ABHILFEMASSNAHME
blinkt (blau)
Die abgegebene Luft enthält Gerüche.
Das Gerät erzeugt ein klickendes oder tickendes Geräusch, während der Plasmacluster-Ionen-Generator betrieben wird.
Der Plasmacluster-Ionen-Generator gibt eine geringe Spur von Ozon ab, die zu Geruch führen kann. Dies ist nicht gesundheitsschädlich.
Die Lautstärke kann sich abhängig von der Luftfeuchtigkeit des Raumes ändern, die Effektivität bleibt jedoch gleich. Falls erforderlich, stellen Sie den Plasmacluster­Ionen-Generator an einem anderen Platz auf.
G-8
Loading...
+ 44 hidden pages