Sharp GP1S59 Datasheet

GP1S59
GP1S59
Horizontal Slit Type Photointerrper
Features
1. Horizontal slit type
2. PWB mouning type
3. Gap between light emitter and detector: 4.2mm
4. Slit width: 0.5mm
5. With a positioning boss
Applications
1. OA equipment, such as printers etc.
Outline Dimensions
Internal connection diagram
23
1 Anode 2 Cathode
C1
+
0.3
0.45
-
0.1
(
)
2.54
41
3 Collector 4 Emitter
AA'section
MIN 10
5.2
0.5
6.8
(
Unit : mm
JAPAN
S59
±
0.3
13.5
±
0.2
4.2
A
B
0.2
±
B'
1.3
4
Dimensions(d
* ( ): Reference dimensions
A'
0.4
(10)
1.8
* Unspecified tolerances shall be as follows ;
4.0< d<=18.0 ± 0.2
)
Tolerance
d<=4.0 ± 0.1
BB'section
9.3
2
+
0.3
-
0.1
1
23
φ 1.2
+
-
1.65
0.2
0.1
)
0.5
Absolute Maximum Ratings
(
)
Parameter Symbol Rating Unit
Input
Forward current I
*1
Peak forward current I Reverse voltage V
F
FM
R
50 mA
1A 6V
Power dissipation P 75 mW
Output
Collector-emitter voltage V Emitter-collector voltage V Collector current I Collector power dissipation P Operating temperature T Storage temperature T
*2
Soldering temperature T
CEO
ECO
C
C
opr
stg
sol
*1 Pulse width<=100µs, Duty ratio: 0.01 *2 For 5 seconds
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
35 V
6V 20 mA 75 mW
- 25 to + 85 ˚C
- 40 to + 100 ˚C 260 ˚C
GP1S59
Electro-optical Characteristics
Parameter Symbol Condition MIN. TYP. MAX. Unit
Forward voltage V
Input
Output I
Transfer chara cteristics
Fig. 1 Forward Current vs. Ambient
Temperature
)
mA
(
F
Forward current I
Fig. 3 Peak Forward Current vs.
Duty Ratio
) mA
(
FM
Peak forward current I
Peak forward voltage V Reverse current I Collector dark current Collector current I Collector-emitter saturation voltage
Response time
60
50
40
30
20
10
0
- 25 0 25 50 75 100 Ambient temperature Ta (˚C
2000
1000
500
200
100
50
20
-2
55252
10
Duty ratio
Rise time t Fall time t
)
Pulse width <= 100µ s T
= 25˚C
a
-1
10
85 - 25 0 25 50 75 100
V
FM
R
CEO
C
CE(sat
r
f
(
F
IF= 20mA - 1.25 1.4 V I-34V
= 0.5A
FM
VR=3V - - 10 µA VCE= 20V - 1 100 nA VCE= 5V, IF= 20mA 0.5 - 10.0 mA
)
IF= 40mA, IC= 0.5mA - - 0.4 V VCE= 2V, IC= 2mA
= 100
R
L
-315
-420
)
µ s µ s
Fig. 2 Collector Power Dissipation vs.
Ambient Temperature
120
)
100
mW
(
C
80 75
60
40
20
Collector power dissipation P
0
Ambient temperature Ta (˚C
85
)
Fig. 4 Forward Current vs.
Forward Voltage
500
Ta= 75˚C
200
)
100
mA
(
50
F
20
10
5
Forward current I
2
0
10
1
0 0.5 1 1.5 2
50˚C
Forward voltage VF (V
25˚C
0˚C
-
25˚C
2.5 3 )
3.5
Loading...