“Plasmacluster” and “Device of a cluster of grapes” are
trademarks of Sharp Corporation.
OPERATION MANUAL
空氣清新機
使用說明書
ENGLISH
中文
* The number in this technology mark indicates an
* The number in this technology mark indicates an
approximate number of ions supplied into air of 1
approximate number of ions supplied into air of 1
3
cm
, which is measured around the center of a room
cm3, which is measured around the center of a room
applicable oor area (at 1.2 m height above the oor)
applicable oor area (at 1.2 m height above the oor)
when the product is placed close to a wall at the MED
when the product is placed close to a wall at the MED
mode setting.
mode setting.
ENGLISH
CONTENTS
Thank you for purchasing this SHARP Air Purier.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
IMPORTANT SAFETY INSTRUCTIONS
........ 2
PARTS NAME .......................................... 4
the air intake, circulates it through a PreFilter, an Active Carbon Deodorizing Filter
and a HEPA Filter inside the main unit, and
then discharges it through the air outlet.
The HEPA Filter can remove 99.97% of
dust particles as small as 0.3 microns that
pass through the lter and also absorb
odors. The Active Carbon Deodorizing
Filter gradually absorbs odors as they pass
through the lter.
Some odors absorbed by the lters will break down over time, causing additional odors.
Depending on usage conditions, and especially if the main unit is used in environments
signicantly more severe than a normal household, these odors may become noticeable sooner
than expected. If these odors persist, the lters should be replaced. (page 10)
NOTE
• The air purier is designed to remove air-suspended dust and the odors.
The air purier is not designed to remove harmful gases such as carbon monoxide contained in cigarette smoke.
The air purier may not completely remove an odor if the source of the odor is still present.
HEPA Filter
Active Carbon
Deodorizing Filter
Pre-Filter
A unique Combination of Air Treatment Technologies
Triple Filteration System + Plasmacluster
High Density Plasmacluster 25000
The higher the PCI density is, the more effective PCI has.
Triple Filteration System
TRAP DUST
Pre-Filter traps dust larger than approx 240 micron particles.
DECREASES ODORS
Active Carbon Deodorizing Filter absorbs many common household odors.
REDUCES TINY DUST, POLLEN & MOLD
HEPA Filter traps 99.97% of particles as small as 0.3 microns.
Unique Airow
Powerful air suction and unique airow quickly and efciently collect dust and other particles.
Faster airow at a 20º angle collects dust at
lower levels in the room for more effective
cleaning.
Plasmacluster can remove static electricity
and can thus prevent dust from attaching to
walls and other surfaces.
ENGLISH
Plasmacluster
By emitting a balance of positive and negative ions, Plasmacluster air treatment is a natural process.
PM2.5 Monitor
• Inform by lighting PM2.5 monitor when Sensitive Dust sensor detects microscopic dust.
• Display the value of PM2.5 in 3 digits.
Plasmacluster Ion Spot Mode
• Recommended when odor and germs adhering to sofa and curtains are concerned.
• Emits highdensity Plasmacluster Ions only in the forward directions.
EN-1
IMPORTANT SAFETY INSTRUCTIONS
Always follow basic safety precautions
when using electrical appliances,
including the following:
WARNING
following to reduce the risk of electrical
shock, re, or injury:
• Read all instructions before using the
main unit.
• Use only a 220 volt outlet.
• This appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience
and knowledge, unless they have
been given supervision or instruction
concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to
ensure they do not play with the
appliance.
• If the power cord is damaged, it must
be replaced by the manufacturer, its
service agent, a Sharp authorized
Service Center or similarly qualied
persons in order to avoid a hazard.
Contact the nearest Service Center
for any problems, adjustments, or
repairs.
• Be sure to remove the power plug,
before performing maintenance, when
removing and attaching and replacing
the lter and when not using for a
long time. Failure to do so can cause
a short circuit resulting in electrical
shock or re.
• Do not use the main unit if the power
cord or plug is damaged or if the
connection to the wall outlet is loose.
• Periodically remove dust from the plug.
• Do not insert ngers or foreign objects
into the air intake or air outlet.
• When removing the power plug, always
hold the plug and never pull on the cord.
Failure to do so can cause a short circuit
resulting in electrical shock or re.
• Be careful not to damage the power
cord, it may cause electric shock, excess
heat or res.
– Always observe the
• Do not remove the plug when your hands
are wet.
• Do not place the main unit near or on
hot objects, such as stoves or heaters,
or where it may come into contact with
steam.
• Do not operate the main unit in rooms
where aerosol insecticides are present.
Do not operate the main unit in rooms
where there is oily residue, incense,
sparks from lit cigarettes, or chemical
fumes in the air. Do not operate the main
unit in places where it may get wet, such
as a bathroom.
• Be cautious when cleaning the main unit.
Strong corrosive cleansers can damage
the exterior.
• Do not expose the main unit to water.
Doing so can cause a short circuit or
electrical shock.
NOTE
interferes with radio or TV reception
If the air purier interferes with radio or
television reception, try one or more of the
following measures:
• Adjust or reposition the receiving
antenna.
• Increase the distance between the main
unit and the radio or TV.
• Connect the equipment into an outlet on
a circuit different from that of the radio or
TV receiver.
• Consult the dealer or a qualied radio or
TV technician.
– What to do if the main unit
EN-2
CAUTIONS CONCERNING
OPERATION
• Do not block the air intake or air outlet.
• Always operate the main unit in an
upright position.
• Do not move the main unit when it is in
operation.
• When moving the main unit, use the
handles on both sides.
• If the main unit is on easily damaged
ooring, an uneven surface, or thick-
piled carpet, lift it up when moving.
• Do not operate the main unit without the
lters properly installed.
• Do not wash and reuse the HEPA lter
and the Active Carbon
Doing so will not improve lter
performance and can also cause electric
shock or operating malfunctions.
• Clean the exterior with a soft cloth only.
Do not use volatile uids or detergents.
The main unit surface may be damaged
or cracked with Benzine, paint thinner
or polishing powder. In addition, the
sensors may malfunction as a result.
• Keep the main unit away from water.
• Do not scrub the Back Panel hard during
its maintenance.
Deodorizing lter.
INSTALLATION GUIDELINES
• Avoid locations where the sensors are
exposed to direct wind.
Doing so can cause the main unit to
malfunction.
• Avoid locations where furniture, fabrics,
or other objects can come in contact with
the main unit and interfere with the intake
and outtake of air.
• Avoid locations where the main unit
is exposed to condensation or drastic
changes in temperature. Appropriate
room temperature is between 0 – 35 ºC.
• Place the main unit on a level and stable
surface with sufcient air circulation.
When placed on heavy carpet, the main
unit may vibrate slightly.
• Avoid locations that generate grease or
oily smoke.
Doing so can cause the main unit
exterior to crack and the sensors to
malfunction.
• The dust collecting ability of the main
unit is effective even when the main unit
is as close to 3 cm from the wall,the
surrounding walls and oor may get dirty.
Please place the main unit at a distance
from the wall.
The wall directly behind the air outlet
may become dirty over time. When using
the main unit for an extended period of
time at the same location, periodically
clean the walls adjacent to it.
FILTER GUIDELINES
• Follow the instructions in this manual for
proper lter care and maintenance.
(page 10)
ENGLISH
EN-3
PARTS NAME
MAIN UNIT
(FRONT)
3
4
5
12
1. Operation Panel
2. Air Outlet (Front/Back)
3. Cleanliness Monitor
4. Front Display
5. Main Unit
6. Handle (2 Locations)
6
7
7. Front Louver
8. Pre-Filter (Back Panel)
9. Air Inlet
10. Active Carbon Deodorizing Filter
11. HEPA Filter
12. Sensor Filter/
Odor and Sensitive Dust Sensor
13. Plasmacluster Ion Generating Unit
14. Unit Holder
15. Unit Cover
16. Unit Cleaning Brush
17. Power Cord, Plug
(BACK)
16
12
8
9
13
1514
17
11
10
EN-4
OPERATION PANEL
8
FRONT DISPLAY
Touch the button with " " to start.
9
ENGLISH
1234567
19
1. Power ON/OFF Button
2. AUTO Button, Indicator Light
3. CLEAN ION SHOWER Button,
Indicator Light
4. Plasmacluster Ion SPOT Button,
Indicator Light
5. MODE Button, Indicator Light
6. Timer Button
(Touch 3 sec.)
(Touch 3 sec.)
7.
FILTER RESET Button
CHILD-LOCK Button
8. Child-Lock Indicator Light
9. Light Sensor
10. PM2.5 Indicator Light
Indicates the Sensitive Dust Sensor detects
microscopic dust.
TURN OFF
Clean Impure
Orange Red
11. Dust Indicator Light
Indicates the Sensitive Dust Sensor detects usual
dust.
TURN OFF
Clean Impure
Orange Red
13121110
1718161514
12. Odor Indicator Light
Indicates the Odor Sensor detects odors.
TURN OFF
Clean Impure
Orange Red
13. Unit Replacement Indicator Light
14. Filter Maintenance Indicator Light
15. ON Timer Indicator Light
16. OFF Timer Indicator Light
17. Plasmacluster Ion Indicator Light
18. DISPLAY
• PM2.5 Monitor
PM2.5 Density 10μg/m3 to 499μg/m3 is displayed.
3
9μg/m
or less
• Timer Monitor
Indicates setting time or remaining time of ON/OFF timer.
19. Cleanliness Monitor
Indicates the air purity of the room in 3 levels with color changes.
Blue Yellow Red
Clean Impure
500μg/m
or more
3
EN-5
Always be sure to remove the
FILTER INSTALLATION
power plug from the wall outlet.
HEPA FILTER / ACTIVE CARBON DEODORIZING FILTER
Remove the Pre-Filter (Back Panel).
1.
Pre-Filter (Back Panel)
Remove the plastic bag from the lter.
2.
Active Carbon
Deodorizing Filter
Install the lters in the correct order as shown.
3.
HEPA Filter
Active Carbon
Deodorizing Filter
HEPA Filter
Tag
Install the Pre-Filter (Back Panel).
4.
2
Click
1
NOTE
• When replacing the lter, making a memo of the start of use date is recommended.
EN-6
OPERATION
START/STOP
STARTSTOP
♪
♪
♪
♪
♪♪♪
♪
AUTO MODE
The fan speed is automatically controlled
depending on the 3 detection. (Sensitive Dust / Odor /
Light)
♪
PLASMACLUSTER ION
SPOT MODE
Use this mode when you want to remove adhering
odor, germs, and other substances from cloths,
sofas and curtains.
ENGLISH
♪
Adjust Front Louver manually.
NOTE
• Emits high density Plasmacluster Ions only in the
forward direction.
• Discharges stronger air for 8 hours. When the
operation nishes, the main unit will return to its
prior operation mode.
• The Plasmacluster Ion can not be turned “OFF”.
NOTE
• Front Display, Cleanliness Monitor automatically
switch ON and Darker based on room brightness.
(When light control is set to "Auto". (page 9))
CLEAN ION SHOWER
MODE
The main unit releases Plasmacluster ions with
strong airow and collects dusts while decreasing
static electricity for 10 minutes. After that, the
DUST sensor sensitivity is automatically increased
and quickly detects impurities and clean the air
powerfully for 50 minutes.
♪
NOTE
• When the operation nishes after 60 minutes,
the unit will return to the prior operation mode.
It is able to change the other mode during this
mode.
• The Plasmacluster Ion can not be turned “OFF”.
FAN SPEED
♪
SLEEP :
The main unit will operate quietly, and the fan speed
is automatically switched depending on the amount
of impurities in the air
The Front Display and Cleanliness Monitor
automatically switches darker or OFF based on
room brightness.
Room is bright: light is darker
Room is dark: light is OFF
and room brightness
POLLEN :
The DUST SENSOR sensitivity is automatically
increased and quickly detects impurities such as
dust and pollen and clean the air powerfully.
♪♪
POLLEN
♪
SLEEP
♪
LOW
♪
MED
♪
HIGH
.
EN-7
ON TIMER
CHILD LOCK
Select the length of time you want.
The Main Unit automatically starts once the
selected time is passes.
(with the Main Unit OFF)
♪
♪♪♪♪♪♪
1hour2hour3hour12hourCancel
• After 8 seconds, the beep sounds.
Front Display
……
OFF TIMER
The operation panel will be locked.
ON
♪
more than 3 sec.
CANCELLATION
♪♪
more than 3 sec.
PLASMACLUSTER ION ON/OFF
When the Plasmacluster function is ON, the
Plasmacluster Ion Indicator light is on. (page 5)
(In operation)
ON
♪
OFF
♪♪
Select the length of time you want.
The Main Unit automatically stops once the selected
time is reached.
(In operation)
♪
♪♪♪♪♪♪
1hour2hour3hour12hourCancel
• After 8 seconds, the beep sounds.
Front Display
……
more than 3 sec.
more than 3 sec.
EN-8
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.