“Plasmacluster” and “Device of a cluster of grapes” are
trademarks of Sharp Corporation.
OPERATION MANUAL
空氣清新機
使用說明書
ENGLISH
中文
* The number in this technology mark indicates an
* The number in this technology mark indicates an
approximate number of ions supplied into air of 1
approximate number of ions supplied into air of 1
3
cm
, which is measured around the center of a room
cm3, which is measured around the center of a room
applicable oor area (at 1.2 m height above the oor)
applicable oor area (at 1.2 m height above the oor)
when the product is placed close to a wall at the MED
when the product is placed close to a wall at the MED
mode setting.
mode setting.
ENGLISH
CONTENTS
Thank you for purchasing this SHARP Air Purier.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
IMPORTANT SAFETY INSTRUCTIONS
........ 2
PARTS NAME .......................................... 4
the air intake, circulates it through a PreFilter, an Active Carbon Deodorizing Filter
and a HEPA Filter inside the main unit, and
then discharges it through the air outlet.
The HEPA Filter can remove 99.97% of
dust particles as small as 0.3 microns that
pass through the lter and also absorb
odors. The Active Carbon Deodorizing
Filter gradually absorbs odors as they pass
through the lter.
Some odors absorbed by the lters will break down over time, causing additional odors.
Depending on usage conditions, and especially if the main unit is used in environments
signicantly more severe than a normal household, these odors may become noticeable sooner
than expected. If these odors persist, the lters should be replaced. (page 10)
NOTE
• The air purier is designed to remove air-suspended dust and the odors.
The air purier is not designed to remove harmful gases such as carbon monoxide contained in cigarette smoke.
The air purier may not completely remove an odor if the source of the odor is still present.
HEPA Filter
Active Carbon
Deodorizing Filter
Pre-Filter
A unique Combination of Air Treatment Technologies
Triple Filteration System + Plasmacluster
High Density Plasmacluster 25000
The higher the PCI density is, the more effective PCI has.
Triple Filteration System
TRAP DUST
Pre-Filter traps dust larger than approx 240 micron particles.
DECREASES ODORS
Active Carbon Deodorizing Filter absorbs many common household odors.
REDUCES TINY DUST, POLLEN & MOLD
HEPA Filter traps 99.97% of particles as small as 0.3 microns.
Unique Airow
Powerful air suction and unique airow quickly and efciently collect dust and other particles.
Faster airow at a 20º angle collects dust at
lower levels in the room for more effective
cleaning.
Plasmacluster can remove static electricity
and can thus prevent dust from attaching to
walls and other surfaces.
ENGLISH
Plasmacluster
By emitting a balance of positive and negative ions, Plasmacluster air treatment is a natural process.
PM2.5 Monitor
• Inform by lighting PM2.5 monitor when Sensitive Dust sensor detects microscopic dust.
• Display the value of PM2.5 in 3 digits.
Plasmacluster Ion Spot Mode
• Recommended when odor and germs adhering to sofa and curtains are concerned.
• Emits highdensity Plasmacluster Ions only in the forward directions.
EN-1
IMPORTANT SAFETY INSTRUCTIONS
Always follow basic safety precautions
when using electrical appliances,
including the following:
WARNING
following to reduce the risk of electrical
shock, re, or injury:
• Read all instructions before using the
main unit.
• Use only a 220 volt outlet.
• This appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience
and knowledge, unless they have
been given supervision or instruction
concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to
ensure they do not play with the
appliance.
• If the power cord is damaged, it must
be replaced by the manufacturer, its
service agent, a Sharp authorized
Service Center or similarly qualied
persons in order to avoid a hazard.
Contact the nearest Service Center
for any problems, adjustments, or
repairs.
• Be sure to remove the power plug,
before performing maintenance, when
removing and attaching and replacing
the lter and when not using for a
long time. Failure to do so can cause
a short circuit resulting in electrical
shock or re.
• Do not use the main unit if the power
cord or plug is damaged or if the
connection to the wall outlet is loose.
• Periodically remove dust from the plug.
• Do not insert ngers or foreign objects
into the air intake or air outlet.
• When removing the power plug, always
hold the plug and never pull on the cord.
Failure to do so can cause a short circuit
resulting in electrical shock or re.
• Be careful not to damage the power
cord, it may cause electric shock, excess
heat or res.
– Always observe the
• Do not remove the plug when your hands
are wet.
• Do not place the main unit near or on
hot objects, such as stoves or heaters,
or where it may come into contact with
steam.
• Do not operate the main unit in rooms
where aerosol insecticides are present.
Do not operate the main unit in rooms
where there is oily residue, incense,
sparks from lit cigarettes, or chemical
fumes in the air. Do not operate the main
unit in places where it may get wet, such
as a bathroom.
• Be cautious when cleaning the main unit.
Strong corrosive cleansers can damage
the exterior.
• Do not expose the main unit to water.
Doing so can cause a short circuit or
electrical shock.
NOTE
interferes with radio or TV reception
If the air purier interferes with radio or
television reception, try one or more of the
following measures:
• Adjust or reposition the receiving
antenna.
• Increase the distance between the main
unit and the radio or TV.
• Connect the equipment into an outlet on
a circuit different from that of the radio or
TV receiver.
• Consult the dealer or a qualied radio or
TV technician.
– What to do if the main unit
EN-2
CAUTIONS CONCERNING
OPERATION
• Do not block the air intake or air outlet.
• Always operate the main unit in an
upright position.
• Do not move the main unit when it is in
operation.
• When moving the main unit, use the
handles on both sides.
• If the main unit is on easily damaged
ooring, an uneven surface, or thick-
piled carpet, lift it up when moving.
• Do not operate the main unit without the
lters properly installed.
• Do not wash and reuse the HEPA lter
and the Active Carbon
Doing so will not improve lter
performance and can also cause electric
shock or operating malfunctions.
• Clean the exterior with a soft cloth only.
Do not use volatile uids or detergents.
The main unit surface may be damaged
or cracked with Benzine, paint thinner
or polishing powder. In addition, the
sensors may malfunction as a result.
• Keep the main unit away from water.
• Do not scrub the Back Panel hard during
its maintenance.
Deodorizing lter.
INSTALLATION GUIDELINES
• Avoid locations where the sensors are
exposed to direct wind.
Doing so can cause the main unit to
malfunction.
• Avoid locations where furniture, fabrics,
or other objects can come in contact with
the main unit and interfere with the intake
and outtake of air.
• Avoid locations where the main unit
is exposed to condensation or drastic
changes in temperature. Appropriate
room temperature is between 0 – 35 ºC.
• Place the main unit on a level and stable
surface with sufcient air circulation.
When placed on heavy carpet, the main
unit may vibrate slightly.
• Avoid locations that generate grease or
oily smoke.
Doing so can cause the main unit
exterior to crack and the sensors to
malfunction.
• The dust collecting ability of the main
unit is effective even when the main unit
is as close to 3 cm from the wall,the
surrounding walls and oor may get dirty.
Please place the main unit at a distance
from the wall.
The wall directly behind the air outlet
may become dirty over time. When using
the main unit for an extended period of
time at the same location, periodically
clean the walls adjacent to it.
FILTER GUIDELINES
• Follow the instructions in this manual for
proper lter care and maintenance.
(page 10)
ENGLISH
EN-3
PARTS NAME
MAIN UNIT
(FRONT)
3
4
5
12
1. Operation Panel
2. Air Outlet (Front/Back)
3. Cleanliness Monitor
4. Front Display
5. Main Unit
6. Handle (2 Locations)
6
7
7. Front Louver
8. Pre-Filter (Back Panel)
9. Air Inlet
10. Active Carbon Deodorizing Filter
11. HEPA Filter
12. Sensor Filter/
Odor and Sensitive Dust Sensor
13. Plasmacluster Ion Generating Unit
14. Unit Holder
15. Unit Cover
16. Unit Cleaning Brush
17. Power Cord, Plug
(BACK)
16
12
8
9
13
1514
17
11
10
EN-4
OPERATION PANEL
8
FRONT DISPLAY
Touch the button with " " to start.
9
ENGLISH
1234567
19
1. Power ON/OFF Button
2. AUTO Button, Indicator Light
3. CLEAN ION SHOWER Button,
Indicator Light
4. Plasmacluster Ion SPOT Button,
Indicator Light
5. MODE Button, Indicator Light
6. Timer Button
(Touch 3 sec.)
(Touch 3 sec.)
7.
FILTER RESET Button
CHILD-LOCK Button
8. Child-Lock Indicator Light
9. Light Sensor
10. PM2.5 Indicator Light
Indicates the Sensitive Dust Sensor detects
microscopic dust.
TURN OFF
Clean Impure
Orange Red
11. Dust Indicator Light
Indicates the Sensitive Dust Sensor detects usual
dust.
TURN OFF
Clean Impure
Orange Red
13121110
1718161514
12. Odor Indicator Light
Indicates the Odor Sensor detects odors.
TURN OFF
Clean Impure
Orange Red
13. Unit Replacement Indicator Light
14. Filter Maintenance Indicator Light
15. ON Timer Indicator Light
16. OFF Timer Indicator Light
17. Plasmacluster Ion Indicator Light
18. DISPLAY
• PM2.5 Monitor
PM2.5 Density 10μg/m3 to 499μg/m3 is displayed.
3
9μg/m
or less
• Timer Monitor
Indicates setting time or remaining time of ON/OFF timer.
19. Cleanliness Monitor
Indicates the air purity of the room in 3 levels with color changes.
Blue Yellow Red
Clean Impure
500μg/m
or more
3
EN-5
Always be sure to remove the
FILTER INSTALLATION
power plug from the wall outlet.
HEPA FILTER / ACTIVE CARBON DEODORIZING FILTER
Remove the Pre-Filter (Back Panel).
1.
Pre-Filter (Back Panel)
Remove the plastic bag from the lter.
2.
Active Carbon
Deodorizing Filter
Install the lters in the correct order as shown.
3.
HEPA Filter
Active Carbon
Deodorizing Filter
HEPA Filter
Tag
Install the Pre-Filter (Back Panel).
4.
2
Click
1
NOTE
• When replacing the lter, making a memo of the start of use date is recommended.
EN-6
OPERATION
START/STOP
STARTSTOP
♪
♪
♪
♪
♪♪♪
♪
AUTO MODE
The fan speed is automatically controlled
depending on the 3 detection. (Sensitive Dust / Odor /
Light)
♪
PLASMACLUSTER ION
SPOT MODE
Use this mode when you want to remove adhering
odor, germs, and other substances from cloths,
sofas and curtains.
ENGLISH
♪
Adjust Front Louver manually.
NOTE
• Emits high density Plasmacluster Ions only in the
forward direction.
• Discharges stronger air for 8 hours. When the
operation nishes, the main unit will return to its
prior operation mode.
• The Plasmacluster Ion can not be turned “OFF”.
NOTE
• Front Display, Cleanliness Monitor automatically
switch ON and Darker based on room brightness.
(When light control is set to "Auto". (page 9))
CLEAN ION SHOWER
MODE
The main unit releases Plasmacluster ions with
strong airow and collects dusts while decreasing
static electricity for 10 minutes. After that, the
DUST sensor sensitivity is automatically increased
and quickly detects impurities and clean the air
powerfully for 50 minutes.
♪
NOTE
• When the operation nishes after 60 minutes,
the unit will return to the prior operation mode.
It is able to change the other mode during this
mode.
• The Plasmacluster Ion can not be turned “OFF”.
FAN SPEED
♪
SLEEP :
The main unit will operate quietly, and the fan speed
is automatically switched depending on the amount
of impurities in the air
The Front Display and Cleanliness Monitor
automatically switches darker or OFF based on
room brightness.
Room is bright: light is darker
Room is dark: light is OFF
and room brightness
POLLEN :
The DUST SENSOR sensitivity is automatically
increased and quickly detects impurities such as
dust and pollen and clean the air powerfully.
♪♪
POLLEN
♪
SLEEP
♪
LOW
♪
MED
♪
HIGH
.
EN-7
ON TIMER
CHILD LOCK
Select the length of time you want.
The Main Unit automatically starts once the
selected time is passes.
(with the Main Unit OFF)
♪
♪♪♪♪♪♪
1hour2hour3hour12hourCancel
• After 8 seconds, the beep sounds.
Front Display
……
OFF TIMER
The operation panel will be locked.
ON
♪
more than 3 sec.
CANCELLATION
♪♪
more than 3 sec.
PLASMACLUSTER ION ON/OFF
When the Plasmacluster function is ON, the
Plasmacluster Ion Indicator light is on. (page 5)
(In operation)
ON
♪
OFF
♪♪
Select the length of time you want.
The Main Unit automatically stops once the selected
time is reached.
(In operation)
♪
♪♪♪♪♪♪
1hour2hour3hour12hourCancel
• After 8 seconds, the beep sounds.
Front Display
……
more than 3 sec.
more than 3 sec.
EN-8
MODE SETTINGS
You can change the functions in the table "Type of setting" below.
Turn the Main Unit power OFF.
1.
2.
more than 3 sec.
Select "Function number".
3.
♪
Reverse Forward
♪
or
・・・・
Set
♪
Select "Setting number".
4.
Reverse Forward
♪
♪
or
Set
Touch Power ON/OFF Button to
5.
♪
♪
ENGLISH
~
nish the setting.
~
♪
Turn off
FunctionSetting
Light Control
You can select the brightness of the Front Display
and Cleanliness Monitor.
Auto Restart
If the Main Unit is unplugged or if there is a power
failure, the Main Unit will resume operation with the
previous settings after power is restored.
Adjustment of Sensor Detection Sensitivity (F3-F5)
Light Sensor
Sensitive Dust Sensor
Turn off
Darker
(default)
Auto
Light automatically switches based on room brightness.
Room
brightness
BrightONDarker
DarkDarkerTurn off
Cancel (default)
ON
Low
Standard
Front Display and
Cleanliness Monitor
ALL MODE
(Except SLEEP)
(default)
SLEEP
MODE
Odor SensorHigh
EN-9
CARE AND MAINTENANCE / REPLACEMENT
HEPA FILTER / ACTIVE CARBON DEODORIZING FILTER
FILTER MAINTENANCE INDICATOR
The lter maintenance Indicator Light
will turn on after approximately
720 hours operating.
This is a reminder to perform the
maintenance described below.
After performing maintenance,
reset the Filter Indicator.
RESET
more than 3 sec.
FILTER MAINTENANCE
Remove the dust on the lters.
CAUTION
Do not wash the lters. Do not expose to sunlight.
(Otherwise these lters may lose efcacy.)
HEPA FILTER
Maintain only the tagged
surface. Do not clean up
the opposite surface.
The lter is fragile, so be
careful not to apply too
much pressure.
Tag
LIFE OF FILTERS
Filter life varies depending on the room environment,
usage conditions, and location of the Main Unit.
Lifespan of HEPA lter and Active Carbon
Deodorizing lter and replacement suggestions are
based on purifying a room in which 5 cigarettes are
smoked per day and the Main Unit's dust collection
and deodorizing performance has declined to half
the level of a new lter.
We recommend replacing the lter more frequently if
the Main Unit is used in conditions signicantly more
severe (PM2.5 etc.,) than a normal household.
HEPA Filter :
About 10 years after opening
Active Carbon Deodorizing Filter :
About 10 years after opening
Replacement Filter Model
Consult your dealer when purchasing a replacement
lter.
HEPA Filter(1 unit) Active CarbonDeodorizing Filter(1 unit)
FZ-J80HFE FZ-J80DFE
ACTIVE CARBON
DEODORIZING
FILTER
Both surfaces can be
maintained.
The lter may be broken if
being too much power is
applied on it, so please handle it with care.
Some odors absorbed by the lters will break down over
time, causing additional odors. Depending on usage
conditions, and especially if the Main Unit is used in
environments signicantly more severe than a normal
household, these odors may become noticeable sooner
than expected.
Replace the lter in those cases or if dust is unable to be
removed after maintenance.
Disposing of lters
Dispose of used lters according to local laws and
regulations.
HEPA Filter material:
• Polypropylene • Polyethylene
Active Carbon Deodorizing Filter material:
• Polypropylene • Polyester
• Activated carbon
EN-10
MAIN UNIT / PRE-FILTER (BACK PANEL)
Wipe with a dry, soft cloth
Pre-Filter
(Back Panel)
Remove the dust gently with a cleaning
tool such as a vacuum cleaner.
NOTE How to clean hard to remove dirt.
Pre-Filter
1. Add a small amount of neutral detergent
to water and soak about 10 minutes.
CAUTION
Do not apply excessive pressure when
scrubbing the pre-lter.
2. Rinse off the neutral detergent pre-lter with clean water.
3. Completely dry the lter in a wellventilated area.
Sensor Filter
1. Remove the Pre-Filter.
2. Remove the sensor lter.
3. If the sensor lter is very dirty, wash it
with water and dry it thoroughly.
Plasmacluster Ion Generating Unit
Remove the unit cover,
1.
and pull out the unit
holder.
Remove dusts from the
2.
electrode section.
Unit Cleaning Brush
Sensor
Filter
(electrode section)
Insert the unit holder
3.
in the Main Unit, and
install the unit cover.
ENGLISH
Before cleaningAfter
Electrode Around the base
CAUTION
• Do not clean with other unit cleaning brush. Doing so could lead to failures in the unit.
• A bent electrode could be cut off and dropped during the cleaning process, but it will not change the performance.
• Do not touch the electrode directly. Doing so could lead to pain/itching.
• Do not transform the electrode section. Doing so can damage it.
• Do not touch the connection terminals. Doing so can damage them.
UNIT REPLACEMENT INDICATOR
When the total operation time exceeds 17,500
hours, the Unit Replacement indicator will ash
to indicate that the Plasmacluster Ion Generating
Unit needs replacement.
Operating time
17,500 hours
Replace the Plasmacluster
Ion Generating Unit
Flash slowly
19,000 hours
Stop the emission of the
Plasmacluster ions.
Flash quickly
* The replacement time is not related to the selected
operation mode.
Replacement Plasmacluster Ion Generating Unit Model
Consult your dealer when purchasing a replacement
Plasmacluster Ion Generating Unit.
IZ-PF10XP-HK
Remove the claw of unit holder (
and remove the Plasmacluster Ion
Generating Unit (
Disposing of Plasmacluster Ion Generating Unit
Dispose of used Plasmacluster Ion Generating Unit
according to local laws and regulations.
material: • Polystyrene terephthalate • electronic parts
cleaning
1
2
),
1
).
2
1
2
EN-11
TROUBLESHOOTING
Odor and smoke persists.
• Check the lters. If they appear to be extremely
dirty, clean or replace them.
The Cleanliness Monitor is blue
even when the air is not clean.
• The air may have been dirty when the main unit
was plugged in. Unplug the main unit, wait one
minute, and then plug the main unit in again.
The Cleanliness Monitor light is
red even when the air is clean.
• Dirty or clogged sensitive dust sensor openings
interfere with sensor operation. Gently clean the
sensor lter or the back panel.
The Main Unit makes a clicking or
ticking sound.
• The main unit may make clicking or ticking
sounds when it is generating ions.
Air discharged from the Main Unit
has an odor.
• Check to see if the lters are extremely dirty.
• Clean or replace the lters.
The Main Unit does not operate
when cigarette smoke is in the air.
• Make sure the Main Unit is installed in a location
in which the sensors can detect cigarette smoke.
• Check to see if the sensitive dust sensor openings
are blocked or clogged. If they are blocked or
clogged, clean the sensor lter or the back panel.
The Main Unit’s Display does not
match weather report.
• Outdoor and indoor as well as the home
environment (the volume of trafc nearby, number
of stories in home, etc.) may cause a reading
different than those data.
ERROR DISPLAY
If error occurs repeatedly, contact the Sharp
Service Center.
• The concentration of
Plasmacluster ion is descending.
Maintain the Plasmacluster
⇒
Ion Generating Unit (electrode
section).
• Is the the Plasmacluster Ion
Generating Unit inserted
properly?
Pull out the the Plasmacluster
⇒
Ion Generating Unit and insert it
to the end again, and then carry
out the operation again.
• Unplug the Main Unit, wait one
minute, and then plug the Main
Unit in again.
The FILTER Maintenance Indicator
Light is on.
• Whenever after performing maintenance of the
lters, connect the power cord to an outlet and
then touch the Filter Reset Button. (page 10)
The Front Display is turned off.
• When Light control is set to "Turn off", the light
is always off. If you do not want the light to be
off, set Light control to “Auto” or "Darker" setting.
(page 9)
The Cleanliness Monitor changes
color frequently.
• The Cleanliness Monitor automatically changes
color when the sensitive dust sensor and odor
sensor* detect impurities. If you are concerned
about the change, you can change sensor
sensitivity. (page 9)
EN-12
SPECIFICATIONS
ModelFX-J80A
Power supply220 V 50 Hz
Fan Speed AdjustmentHIGHMEDLOW
3
Fan Speed (m
Noise Level (dBA)474515
Rated Power (W)48284.0
Standby Power (W) 1.3
Applicable Room Size (m
/hour)48028860
1
2
) *
ENGLISH
~ 62
High density Plasmacluster ion
recommended room size (m
Cord Length (m)2.0
Dimensions (mm)416 (W) × 291 (D) × 728 (H)
Weight (kg)10.6
*1 • The recommended room size is appropriate for operating the main unit of maximum fan speed.
• The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes.
*2 • Room size in which approximately 25000 ions per cubic centimeter can be measured in the center of the room when the main unit is
placed next to a wall, is running at MED mode settings, and is at a height of approximately 1.2 meters from the oor.
2
2
)
*
~ 35
Standby Power
When the main unit’s power plug is inserted in a wall outlet it consumes standby power in order to operate electrical
circuits. To conserve energy, unplug the power cord when the main unit is not in use.