Sharp FU-Z31E User Manual

R
*Plasmacluster is a trademark of Sharp
Corporation.
*Plasmacluster adalah Merek Dagang dari
Sharp Corporation.
AIR PURIFIER OPERATION MANUAL
ENGLISHINDONESIA
Free standing type Tipe Berdiri
PETUNJUK PENGOPERASIAN AIR PURIFIER
No. Reg. : 03/DJ-ILMEA/MG/I/2000
Please read before operating your new Air Purier
Some odour ingredients absorbed by the lter may become separated and
may be discharged through the air outlet and result in additional odour. De­pending on the usage environment, especially when the product is used in
a condition signicantly more severe than household use, this odour may
become strong in a shorter period than expected.
In this case we recommend purchasing the optional replacement lter.
NOTE
• The air purier is designed to remove air-suspended dust and odour, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke). If the odour sources still exist, it cannot
completely remove the odour (for example, odours from construction materials and pet odours).
• It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.
Dust Collection / Deodorising Filter
Elements removed by filter
Dust
pollen, dust, particles of cigarette smoke, pet dander
Odour
cigarette smoke odour, household odour (toilet / raw garbage / pet, etc.)
ENGLISH
FEATURES
"Plasmacluster" technology
Plasmacluster technology uses plas­ma discharge to produce and release the same positive and negative ions
as those found in nature ("Plasma­cluster ions").
This is a unique air cleaning technolo­gy of the SHARP CORPORATION for breaking down and inactivating such potential allergens as the fecal matter or corpses of aerial mites* and mould and bacteria *
1
, viruses *2
3
suspended in the air, and has been substantiated by third-party organisations both in Japan and overseas. When there is a high density of Plas­macluster ions in the air, the smell of cigarette smoke trapped in curtains or sofas is removed in about 80 min-
4
utes*
, and when clothing is hung in a place exposed to the direct air ex­pelled from the unit generating Plas­macluster ions, the smell of sweat is reduced to a virtually imperceptible
level in one night (about 6 hours).
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
• WARNING ....................................................
• CAUTIONS CONCERNING OPERATION ...
• INSTALLATION GUIDELINES ......................
• FILTER GUIDELINES ..................................
PART NAMES
• MAIN UNIT DISPLAY ...................................
• ILLUSTRATIVE DIAGRAM ..........................
• INCLUDED ...................................................
• BACK ............................................................
PREPARATION
• FILTER INSTALLATION ...............................
OPERATION
• MAIN UNIT OPERATION .............................
CARE AND MAINTENANCE
• BACK PANEL AND SENSOR .......................
• UNIT .............................................................
• FILTER REPLACEMENT GUIDELINES .....
TROUBLESHOOTING
...............................................
............................................
.................................................
.....................
..............................
.....
E-2 E-2
E-3 E-3 E-3
E-4 E-4
E-4 E-5 E-5
E-6 E-6
E-8 E-8
E-9 E-9
E-9
E-10
E-11
ENGLISHINDONESIA
*1 Graduate School of Advanced Sci-
ences of Matter, Hiroshima University, Japan
Measurement of action on the poten-
tial allergens of aerial mites in (13m²)
*2 Retroscreen Virology, Ltd., London, UK Measurement of ratio of viruses elimi-
nated from the air in a 1m³ box
*3 Ishikawa Health Service Association,
Japan
Measurement of aerial mold and bac-
teria with an air sampler (13m²)
*4 Japan Spinners Inspecting Foundation,
Japan
Evaluation of deodorizing effect on
odor-imbued fragments of cloth
SPECIFICATIONS
......................................
Thank you for purchasing the SHARP Air Puri-
er. Please read this manual carefully for the
correct usage information. Before using this product, be sure to read the section: “Important Safety Instructions.” After reading this manual, retain it in a conven­ient location for future reference.
E-1
E-12
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened.
Periodically remove dust from the power plug.
• Do not insert ngers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or re from short circuit may occur as a result.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not using the unit.
Electrical shock from bad insulation and/or re from short circuit may occur as a result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp Approved Service Centre or similarly qualied person in order to avoid a hazard.
Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity conditions, such as a bathroom.
Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
Only Sharp Approved Service Centre should service this air purier. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given su­pervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
- To reduce the risk of electrical shock, re or injury to persons:
NOTE
If this air purier should cause interference to radio or television reception, try to correct the interfer­ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con­nected.
• Consult the dealer or an experienced radio/TV technician for help.
- Radio or TV Interference
E-2
CAUTIONS CONCERNING OPERATION
• Do not block the intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
• Do not lay the unit down when using.
• Always hold the handle on both sides of the unit when moving it.
Holding the back panel when carrying may cause it to detach, thus dropping the unit and resulting
in bodily injury.
• Do not operate the unit without the lter.
• Do not wash and reuse the lter .
Not only does it not improve lter performance, but also may cause electrical shock or malfunction.
• Clean the exterior with a soft cloth only.
The unit surface may be damaged or cracked. In addition, the sensors may malfunction as a result.
INSTALLATION GUIDELINES
• During the operation of the product, please place the unit at least 2 m away from equipment
utilizing electrical waves such as televisions, radios or wave clocks.
• Avoid locations where curtains, etc., come into contact with the intake or air outlet.
Curtains, etc., may become dirty or a malfunction may occur.
• Avoid locations where the unit is exposed to condensation, due to rapid temperature changes.
(If it is unavoidable please allow unit to stand for 1 hour before switching on.)
(Use under appropriate conditions between 0 and 35˚C in the room.)
• Place on a stable surface with sufcient air circulation.
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.
• Do not install when there is a possibility of soot, such as in a kitchen, etc.
The unit surface may crack as a result.
• Leave about 60cm of space from the wall.
The wall behind the air outlet may become dirty as time passes. When using the unit for extended
period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lter.
Use only lter designed for this product.
ENGLISHINDONESIA
E-3
PART NAMES
MAIN UNIT DISPLAY
POWER ON/OFF Button
Plasmacluster Ion ON/OFF Button
MODE Button
Odour Sensor
Fan Speed Indicator Lights
CLEAN SIGN
The odour sensor continuosly monitors the air and changes colour depending on air punity.
ILLUSTRATIVE DIAGRAM
Plasmacluster Ion ON/OFF Indicator Light
Green Orange Red
Clean Very Impure
Handle
E-4
Main Unit
INCLUDED
• Operation manual
BACK
Tab
Handle
Filter
(Dust Collection / Deodorising Filter)
ENGLISHINDONESIA
Date Label
Back Panel
Air Outlet
Air Inlet
Power Cord
Plug
(Shape of plug depends on country.)
E-5
PREPARATION
1
2
Be sure to remove the power plug from the wall outlet.
FILTER INSTALLATION
To maintain the quality of the lter, they are installed in the main unit and packed in plastic bag. Be sure to remove the lter from the plastic bag before using the unit.
Tab
Remove the lter
Remove the Back Panel.
1
Pull the tab at the top of the Back Panel.
Remove the Filter from the
2
plastic bag.
Intall the lter
Place the Filter within the main unit.
1
Do not install the lter backwards or the unit will not operate properly.
E-6
Replace the Back Panel to the main unit.
2
Push until it clicks into place.
ENGLISHINDONESIA
Fill in the usage start date on the Date Label.
3
Use the date as a guide for the lter replacement schedule.
E-7
Date Label
OPERATION
MAIN UNIT OPERATION
MODE Button
Plasmacluster Ion ON/OFF Button
Fan Speed Indicator Lights
Plasmacluster Ion Indicator Light
Power ON/OFF Button
• Press to start operation (short beep) and stop operation (long beep)
• Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off.
• Unless the power cord has been unplugged, the opera­tions starts in the previous mode it was operated in.
MODE Button
• Press the MODE Button to select the desired fan speed. Indicator Lights will show the fan speed currently select­ed.
• The operation mode can be switched as below.
AUTO operation
The fan speed is automatically switched
(between HIGH and LOW) depending on the
amount of impurities in the air. The sensors
detect impurities for efcient air purcation.
POWER ON/OFF Button
LOW operation
The unit will operate quietly using minimal air intake.
MAX operation
The unit will operate at a fan speed of MAX.
Plasmacluster Ion ON/OFF Button
Press the Plasmacluster Ion ON/OFF Button to turn Plasmacluster Ion Mode ON and OFF. When Plasmacluster Ion is ON, the Plasmacluster Ion
Indicator Light will turn on.(blue)
<When the CLEAN-SIGH is too bright> Press the Plasmacluster Ion ON/OFF Button for 3 sec­onds to switch the CLEAN-SIGN ON and OFF.
MEDIUM operation
The unit will operate at a fan speed of MEDIUM.
E-8
CARE AND MAINTENANCE
To maintain optimum performance of this air purier, please clean the unit including the lter
periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet
hands. Electrical shock and/or bodily injury may occur as a result.
BACK PANEL and SENSORS
Care Cycle
Gently remove dust from the sensor opening and the back panel, using a vacuum cleaner attachment or similar tool.
<When the back panel has stubborn dirt>
In case of heavy dirt, soak the back panel in water with a small amount of kitchen detergent.
1
(Approx. 10min.) (Avoid scrubbing the back panel hard when washing.)
Rinse the back panel repeatedly with clean water to remove the solution residue.
2
Drip dry lter to remove excess water.
3
Whenever dust accumulates on the unit or every 2 months
Back Panel
ENGLISHINDONESIA
UNIT
Care Cycle
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are
allowed to remain, they may become difcult to remove.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile uids
Benzine, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
Whenever dust accumulates on the unit or every 1 month
E-9
CARE AND MAINTENANCE
FILTER REPLACEMENT GUIDELINES
Filter life vary depending on the room environment, usage, and location of the unit.
If dust or odour persists, replace the lter.
(Refer to “Please read before operating your new Air Purier”)
Guide for lter replacement timing
• The following lter life and replacement period is based on the condition of smoking 5
cigarettes per day and the dust collection/deodorization power is reduced by half compared
with that of new lter.
We recommend to replace the lter more frequently if the product is used in a condition sig-
nicantly severer than normal household use.
• Filter About 2 years after opening
REPLACING THE FILTER
See page E-6,7 for directions on
1
how to install the filter when re­placing.
Fill in the usage start date of the
2
lter on the Date La
bel.
Date Label
Replacement Filters
Model : FZ-Y30SFE
• Dust Collection / Deodorizing Filter : 1 unit
Dust Collection / Deodorizing Filter
Please consult your dealer for purchase of replacement lter.
Disposal of Filter
Please dispose of the replaced lter according to the local disposal laws and regulations.
Filter materials :
• Filter : Polypropylene
• Frame : Polyester
• Deodorizer : Activated charcoal
E-10
TROUBLESHOOTING
Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction.
SYMPTOM
Odours and smoke are not
removed.
The Clean Sign illuminates green even when the air is impure.
The Clean Sign illuminates orange or red even when the air is clean.
A clicking or ticking sound
is heard from the unit.
The discharged air has an odour.
REMEDY (not a malfunction)
• Replace the lter if it appear to be heavily soiled. (See E-10)
• The air could be impure at the time the unit was plugged in. Unplug the unit, wait one minute, and plug the unit in again.
• Sensor operation is affected if the odour sensor openings are dirty or clogged. Gently clean the dust sensors.
(See E-9)
• Clicking or ticking sounds may be audible when the unit is gen erating Plasumacluster ions.
• Check to see if the lter are heavily soiled.
• Clean or replace the lter.
• Plasmacluster Air Purifiers emit small traces of ozone which
may produce an odour.
-
ENGLISHINDONESIA
The unit does not operate
when cigarette smoke is in
the air.
The Clean Sign are turned off.
The Clean Sign lights change colour frequently.
• Is the unit installed in a location that is difcult for the sensor to
detect cigarette smoke?
• Are the dust sensor openings blocked or clogged?
(In this case, clean the openings.) (See E-9)
• Check to see if the Lights OFF Mode selected. If so, then press the Plasmacluster Ion ON/OFF Button to activate the indicator
lights. (See E-8)
• The Clean Sign lights automatically change colours as impuri­ties are detected by the odour sensor.
E-11
SPECIFICATIONS
Model
Power supply
Fan Speed Operation
High density Plasmacluster ion recommended room size
Size of a room which is appropriate for operating the unit at maximum fan speed.
*1
•It indicates the space where a certain amount of dust particles can be removed in 30
minutes(JEM1467).
*2
Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the
center of the room (at a height of approximately 1.2 meters from the oor) when the product is
placed next to a wall and run at the MAX operation position.
Standby Power
Fan Speed Adjustment
Rated Power
Fan Speed
Recommended Room Size
Cord Length
Dimensions
Weight
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 1.0W of standby power. For energy saving, unplug the power cord when the unit is not in use.
MAX
49W
180m
3
/hour
356mm(W)x180mm(D)x510mm(H)
FU-Z31E
220-240V 50/60Hz
MED
32W
120m3/hour
2 *1
~21m
2 *2
~13m
2.0m
5.0kg
LOW
23W
60m3/hour
The class of the HEPA lter by EN 1822 is H10.
E-12
SHARP CORPORATION
OSAKA, JAPAN
Printed in China TINS-A420KKRZ 10C- CN 1
Loading...