The air purifier draws in room air via its air intake, letting the air pass
through an Active Carbon Filter (deodorisation lter) and a HEPA Filter (dust
collection lter) inside the unit, then discharges the air from its air outlet.
The air purier unit repeats this process continuously when its internal fan is
working.
As air passes through the HEPA lter it removes 99.97% of dust particles (as
small as 0.3 microns).The Active Carbon Filter gradually absorbs odour elements as they repeatedly pass through the lter.
Some odour ingredients absorbed by the lters may become separated and
may be discharged through the air outlet and result in additional odour. Depending on the usage environment, especially when the product is used in
a condition signicantly more severe than household use, this odour may
become strong in a shorter period than expected.
If the odour persist the lters should be replaced.
In this case we recommend purchasing the optional replacement lter.
NOTE
• The air purier is designed to remove air-suspended dust and odour, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke). If the odour sources still exist, it cannot
completely remove the odour (for example, odours from construction materials and pet odours).
It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.
ENGLISH
FEATURES
"Plasmacluster" technology
Plasmacluster technology uses plasma discharge to produce and release
the same positive and negative ions
as those found in nature ("Plasma-
cluster ions").
This is a unique air cleaning technol-
ogy of the SHARP CORPORATION
for breaking down and inactivating
such potential allergens as the faecal
matter or corpses of aerial mites*1,
viruses*2 and mould and bacteria*
suspended in the air, and has been
substantiated by third-party organisations both in Japan and overseas.
When there is a high density of Plasmacluster ions in the air, the smell of
cigarette smoke trapped in curtains
or sofas is removed in about 80 minutes*4, and when clothing is hung in
a place exposed to the direct air expelled from the unit generating Plasmacluster ions, the smell of sweat is
reduced to a virtually imperceptible
level in one night (about 6 hours).
Japan
Measurement of action on the potential
allergens of aerial mites (in the area of
13m²).
*2 Retroscreen Virology, Ltd., London, UK
Measurement of ratio of viruses re
moval from the air in a 1m³ box
*3 Ishikawa Health Service Association,
Japan
Measurement of aerial mould and bac
teria
in a 13m² lab using an air sampler.
*4 Japan Spinners Inspecting Foundation,
Japan
Evaluation of deodorising effect on
odour-imbued fragments of cloth
TROUBLE SHOOTING
SPECIFICATIONS
-
-
.............................
......................................
E-13
E-14
Thank you for purchasing the SHARP Air Purier. Please read this manual carefully for the
correct usage information. Before using this
product, be sure to read the section: “Important
Safety Instructions.”
After reading this manual, retain it in a convenient location for future reference.
E-1
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
WARNING
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet
is loosened.
• Periodically remove dust from the power plug.
• Do not insert ngers or foreign objects into the air intake or outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or re from short circuit may occur as a result.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not using the
unit.
Electrical shock from bad insulation and/or re from short circuit may occur as a result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp Approved Service Centre or similarly qualied person in order to avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air or in very high humidity conditions, such as a
bathroom.
• Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
• Only Sharp Approved Service Centres should service this air purier. Contact your nearest Ap-
proved Service Centre for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
- To reduce the risk of electrical shock, re or injury to persons:
NOTE
If this air purier should cause interference to radio or television reception, try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
- Radio or TV Interference
E-2
IMPORTANT SAFETY INSTRUCTIONS
CAUTIONS CONCERNING OPERATION
• Do not block the air intake and/or outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
• Do not lay the unit down when turned on.
• Always hold the handle on the back of the unit when moving it.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting
in personal injury.
• Do not operate the unit without the lter.
• Do not wash and reuse HEPA lter .
It not only does not improve lter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
Otherwise the unit surface may get damaged or cracked.In addition, the sensors may malfunction as a result.
INSTALLATION GUIDELINES
• During operation, please place the unit at least 2 m away from equipment which may be
subject to electrical waves such as televisions, radios or wave clocks.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid locations where curtains, etc., come into contact with the air intake or outlet.
Curtains, etc., may become dirty or a unitl malfunction may occur.
• Avoid locations where the unit is exposed to condensation, due to drastic temperature
changes.
(Use under appropriate conditions between 0 and 35˚C in the room.)
• Place on a stable surface with sufcient air circulation.
When placing the unit on a thick carpeted area, it may cause the unit to vibrate slightly.
• Do not install when there is a possibility of soot, such as in a kitchen, etc.
The unit surface may crack or the sensor may malfunction as a result.
• Leave about 60cm of space from the wall.
The wall behind the air outlet may become dirty as time passes. When using the unit for an ex-
tended period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lters.
Use only lters designed for this product.
ENGLISH
E-3
Fan Speed Indicator Lights
Plasmacluster Ion
ON/OFF
Indicator Light
POWER ON/OFF Button
Plasmacluster ON/OFF Button
Fan Speed Button
Odour Sensor
PART NAMES
Main Unit
Odour Sensor
HEPA Filter
(blue/white)
(black)
Filter Support
Front Panel
Washable Active
Carbon Filter
MAIN UNIT DISPLAY
ILLUSTRATIVE DIAGRAM
E-4
CLEAN - SIGN Light
Plasmacluster Indicator Light(blue)
Blue light : Plasmacluster ON
Green
CleanSlightly ImpureVery Impure
OrangeRed
Air Outlet
Date Label
Air Inlet
Power Cord
Plug
Handle
Light off : Plasmacluster OFF
The colour changes according to the air condition.
ENGLISH
BACK
(Shape of plug depends on country).
INCLUDED
• Operation manual
E-5
PREPARATION
1
FILTER INSTALLATION
To maintain the quality of the lters, they are installed in the main unit and packed in
plastic bags. Be sure to remove the lters from the plastic bags before using the unit.
Remove the lters
Remove the Front Panel.
1
Pull the bottom of the Front Panel.
Remove the Filter Support.
2
Pinch the two tabs and lift to remove.
Be sure to remove the power plug from the wall outlet.
Front Panel
Up side Tabs
Remove the Active Carbon
3
Filter and HEPA Filter.
Remove the Active Car-
4
bon Filter and HEPA Filter
from the plastic bags.
Tabs
Active Carbon Filter
HEPA Filter
Main Unit
Active Carbon Filter
HEPA Filter
E-6
Install the lters
2
Tab
2
Pl ace t he HE PA F ilt er
1
within the main unit with
the tabs facing up.
Do not in s tall the fil t er bac kwards or the unit will not operate
properly.
Place the Active Carbon
2
Filter on top of the HEPA
Filter.
Make s ure that the tab of the
HEPA Filter remains visible.
Insert the bottom side tabs of the Filter Support
3
into the associated holes of the main unit.
Next push the upside tabs into the main unit.
Holes
Active Carbon Filter
HEPA Filter
Tabs
Tabs
ENGLISH
Up side Tabs
Fix the Front Panel to the
4
main unit.
Fil l in th e us age sta rt
5
date on the Date Label.
Use the date as a guide for the
Filter Replacement schedule.
Filter Support
Bottom side tabs
Date Label
E-7
OPERATION
Plasmacluster ON/OFF Indicator Light
Fan Speed ButtonPlasmacluster ON/OFF ButtonPOWER ON/OFF Button
CLEAN - SIGN Light
Plasmacluster Indicator Light
Fan Speed Indicator Lights
MAIN UNIT OPERATION
Power ON/OFF Button
• Press to start operation (short beep) and stop operation (long
beep)
• Plasmacluster Indicator Light and Fan Speed Indicator Light
turn on/off.
• Unless the power cord has been unplugged, the operation
starts in the previous mode it was operated in.
Fan Speed Button
• The operation mode can be switched as below.
AUTO operation
The fan speed is automatically switched (MEDIUM,
LOW) depending on the amount of impurities in the air.
The sensors detect the impurities for efcient air puri-
cation.
ION SHOWER operation
By continuously discharging a strong airflow for 15
minutes the unit effectively removes airborne dust, pollen, mould and allergens from the air as they are drawn
through the lter system.
• When the operation is nished, the unit will return to
the AUTO operation.
POLLEN mode operation
The unit will operate at HIGH* fan speed for 10 min-
ut e s , th e n wi l l al t e rnat e b e twe e n ME DIUM and
HIGH* for 20 minutes.
10 minutes: HIGH fan speed
20 minutes:
20 minutes: HIGH fan speed
MEDIUM fan speed
MAX operation
The unit will operate at a
fan speed of MAX.
MEDIUM operation
The unit will operate at a
fan speed of MEDIUM.
SILENT operation
Th e uni t wil l ope r a te
quietly using minimal air
intake.
* HIGH fan speed is an intermedi-
ate speed between MED IUM
and
MAX.
* LOW fan speed is an intermedi-
ate speed between SILENT and
MEDIUM.
E-8
Fan Speed Button
Plasmacluster ON/OFF Button
POWER ON/OFF Button
CLEAN - SIGN Light
The colour changes according to the air condition.
Green
CleanSlightly ImpureVery Impure
OrangeRed
ABOUT THE CLEAN-SIGN
• The condition of the CLEAN-SIGN depends on the room air condition detected by the Odour Sensor
when the plug is inserted into the wall outlet.
• It is possible to have a green CLEAN SIGN if there are impurities in the air when the product is rst turned on.
After a while, however, the base impurity rate will be adjusted to detect room air condition correctly.
Plasmacluster ON/OFF Button
Press the Plasmacluster ON/OFF Button to turn Plasmacluster
Ion Mode ON and OFF.
When Plasmacluster is ON, both the Indicator Light and Plas-
macluster Indicator Light will turn on (blue).
ENGLISH
LIGHTS ON/OFF Button
(Press the Plasmacluster ON/OFF Button for 3 seconds).
Switches the Plasmacluster Indicator Light and CLEAN-SIGN
Light either ON or OFF.
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
Set to “low” if CLEAN-SIGN Light is constantly red to reduce sensitivity, and set to
“high” if CLEAN-SIGN Light is constantly green to increase sensitivity.
With the unit OFF, press the Fan Speed Button for 3 seconds
1
The Fan Speed Indicator Lights will display the currently set sensor sensitivity level. The
factory setting is Standard, indicated by the MED light.
Press the Fan Speed Button to set the
desired sensor sensitivity
2
Refer to the diagram on the right to select the
desired sensor sensitivity level.
Press the Power ON/OFF Button.
3
Note that if the Power ON/OFF Button is not
pushed within 8 seconds of adjusting sensor sensitivity, the setting will be saved automatically. The sensor sensitivity setting will be
saved even if the unit is unplugged.
.
.
Fan Speed
Indicator Light
Sensor Detection
sensitivity
High
Standard
Low
E-9
CARE AND MAINTENANCE
Care Cycle
1 month
Care Cycle
2 months
To maintain optimum performance of this air purier, please clean the unit including the sensor and lters periodically.
When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet
hands. Electrical shock and/or bodily injury may occur as a result.
MAIN UNIT
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to
remain, they may become hard to clean.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile uids
Benzine, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
Keep the unit away from water
ODOUR SENSOR
The sensitivity of the sensor will become unstable
if the odour sensor is dirty or blocked. Remove
dust from the surface of the sensor opening using
a vacuum cleaner.
Hole of sensor
E-10
WASHABLE ACTIVE CARBON FILTER CARE
CAUTION
CAUTION
CAUTION
WASHABLE ACTIVE CARBON FILTER CARE
HAND WASH ONLY!
DO NOT TUMBLE DRY!
Care Cycle
We recommend replacing the active carbon lter every six months.
Clean the lter as offen as necessary when odour persists.
Fil l a large c o ntainer w i th
1
lukewarm water, add a mild
kitchen detergent and stir.
D i l u t e as in d i cated on the detergent container.
Allow the filter to soak ap-
2
proximately 10 minutes .
Dry lter completely in a well ventilated
5
area. If possible, dry outdoors.
• Avoid dry ing filter outdoors during incl ement
weather (e.g. rain or cold temperatures).
• Do not allow lter to freeze.
• If lter is dried indoors, take precautions, such as
placing towels, etc under the lter to prevent water damage to the oor.
Reinstall the Filters.
6
Reinstall the lters as shown on Page E-6,7.
Dry lter completely before replacing to pre-
vent odours.
Do not operate unit without all lters properly
installed.
ENGLISH
3
4
Ri n s e th or o u gh l y w i t h
clean water.
I f ri n s i n g in a
c o nt a i n er, b e
sure t o rinse 3
t o 4 ti m es so
that the odour is
rinsed thorough-
ly from the lter.
Remove excess water.
The lter will be saturated with water after rinsing. To decrease drying
time, wrap the lter in an old thick
towel so that excess water can be
removed.
Some c a r b o n
may adhere to
the to w el, i f
yo u to w el-d ry
the filter, but it
is harmless.
Active Carbon
Filter
E-11
Filter Support
HEPA Filter
Main Unit
CARE AND MAINTENANCE
FILTER REPLACEMENT GUIDELINES
Depending on the usage environment, air outlet odour may become
strong after several months.
If dust or odour cannot be removed easily, replace the lters.
(Refer to “Please read before operating your new Air Purier”)
Guide for lter replacement timing
• The following lter life and replacement period is based on the condition of smoking 10
cigarettes per day and the dust collection/deodorisation power is reduced by half compared with that of new lters.
We recommend to replace the lters more frequently if the product is used in a condition
signicantly more severe than normal household use.
•HEPA Filter About 2 years after opening
•Active Carbon Filter About 2 years after opening
REPLACING THE FILTERS
See page E-6,7 for directions on
1
how to install the filters when
replacing.
Fill in the usage start date of
2
the lters on the Date Label.
Replacement Filters
Model: FZ-W28SFJ
• HEPA Filter : 1 unit
• Active Carbon Filter: 1 unit
Please consult your dealer for purchase
of replacement lters.
Disposal of Filters
Please dispose of replaced lters according to the local disposal laws and regulations.
HEPA Filter materials:
•Filter: Polypropylene
•Frame: Polyester
Active Carbon Filter Materials:
•Deodoriser: Activated charcoal
•Nonwoven fabric : Polyester
Date Label
E-12
TROUBLESHOOTING
Before calling for repair, please review the list below, since the problem may not be a unit malfunction
SYMPTOM
Odours and smoke are not
removed.
The CLEAN-SIGN Light shows
green even when the air is impure.
The CLEAN-SIGN Light shows
orange or red even when the
air is clean.
A clicking or ticking sound is
heard from the unit.
The discharged air has an aro-
ma or odour.
The unit does not operate when
cigarette smoke is in the air.
• Clean or replace the lters if they appear to be heavily soiled.
(Refer to E-11,E-12)
• The air could be impure at the time the unit was plugged in. (Refer
to E-9) Pull out the plug from the electrical outlet, and insert the
plug one minute later.
• The sensiti vity o f the s ensor becom es unsta ble when t he
opening of the odour sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner. (Refer to E-10)
• Clicking or ticking sounds may be audible when the unit is gen-
erating ions.
• Check to see if the lters are heavily soiled.
Replace the lters.
• Plasmacluster Air Purifiers emit small traces of ozone which
may produce an odour. These ozone emissions are well below
safety levels.
• Is the unit installed in a location that is difcult for the sensor to
detect cigarette smoke?
• Is the odour sensor opening blocked or clogged?
(In this case, clean the opening.) (Refer to E-10)
REMEDY (not a malfunction)
.
ENGLISH
The Plasm acluste r Indi cator
Light or the CLEAN-SIGN Light
will not activate.
• Check to see if the Lights OFF Mode is selected. If so, then
press the Plasmacluster ON/OFF Button for 3 seconds to activate the indicator lights.
(Refer to E-9)
If you still require service, contact your SHARP approved service centre.
SHARP approved service centre locations can be found in the support area of our website:
Australia : http://www.sharp.net.au
New Zealand : http://www.sharp.net.nz
ERROR DISPLAY
LAMP INDICATION
The “SILENT” Fan Speed Indi-
cator Light blinks.
Fan motor is disconnected or abnormal.
Operation stops.
• Pressing the POWER ON/OFF button will reset the error dis
play, but if error occurs again, contact the shop where you
purchased the unit.
E-13
REMEDY
-
SPECIFICATIONS
Model
Power supply
Fan
Speed
Operation
High density Plasmacluster ion applicable oor surface
Numbers in parentheses indicate the power consumption when the Plasmacluster indicator light and the
*1
CLEAN-SIGN light are off.
The applicable oor surface area is appropriate for operating the unit at maximum fan speed.
*2
•Applicable oor surface area indicates the space where a certain amount of dust particles can be
removed in 30 minutes.(JEM1467)
*3
Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the
center of the room (at a height of approximately 1.2 meters from the oor) when the product is
placed next to a window and run at the MAX operation position.
Fan Speed Adjustment
Rated Power
Fan Speed
Recommended Room Size
Cord Length
Dimensions
Weight
MAX
33W
168m3/hour
410mm(W)x158mm(D)x430mm(H)
FU-W28J
220-240V 50Hz
MED
12W
90m3/hour
2 *2
~21m
2 *3
~10m
2.0m
4.3kg
SILENT
3.9W(3.5W)
30m3/hour
*1
The class of the HEPA lter by EN1822 is H10.
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the
wall outlet, this product consumes about 0.8W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.
E-14
Memo
ENGLISH
Memo
Memo
ENGLISH
TINS-A353KKRZ
Printed in China
09K
1
SHARP CORPORATION OF AUSTRALIA PTY.LTD.
A. B. N. 40 003 039 405
1 HUNTINGWOOD DRIVE, HU NTINGWOOD, N.S.W. 2148
P.O.BOX 6827, BLACKTOWN. N.S.W. 2148
SHARP CORPORATION OF N EW ZEALAND LIMITED
59 HUGO JOHNSTON DRIVE PENROSE, AUCKLAND
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.