SHARP ERA310I, ER-A310, ER-A330 Service Manual

INSTALLATION MANUAL
ER-A310
ER-A330
CODE: 00ZERA310VIME
ELECTRONIC CASH REGISTER
MODEL ER-A310
MODEL ER-A330
SRV Key : LKGIM7113RCZZ PRINTER: ER-A310 : CR-510
: ER-A330 : UCR-812A
CONTENTS
CHAPTER 1. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
CHAPTER 2. LIST OF OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
CHAPTER 3. REMOVING THE TOP CABINET (For ER-A310 & ER-A330) . . . . . . 2
CHAPTER 4. REMOVING THE BOTTOM CABINET (Only for ER-A330) . . . . . . . . 3
CHAPTER 5. REMOVING THE PRINTER UNIT (For ER-A310 & ER- A 330) . . . . . 4
CHAPTER 6. REMOVING THE MAIN PWB (For ER-A310 & ER-A330) . . . . . . . . . 4
CHAPTER 7. REMOTE DRAWER: ER-04DW (For ER-A310 & ER-A330) . . . . . . . 5
CHAPTER 8. DRAWER FIXING KIT: DKIT–8670RCZZ (Only for ER-A330) . . . . . 6
CHAPTER 9. SHIELD PLATE KIT: DKIT-8666BHZZ (Only for ER-A330) . . . . . . . . 7
CHAPTER 10. ONE HO LE CASHIER KEY KIT: DKIT-8669BHZZ
(For ER-A310 & ER-A330) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CHAPTER 11. KEY TOP KIT: ER-11KT7/12KT7/22KT7/11DK7/51DK7
(For ER-A310 & ER-A330) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Parts marked with "! " is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
This document has been published to be used
SHARP CORPORATION
for after sales service only. The contents are subject to change without notice.
CHAPTER 1. GENERAL
This manual describes the ER-A310/A330 disassembly procedures and the option attachment procedures. For assembly procedures, reverse the disassembly procedures. For attachment of options which do not require special descriptions, descriptions are omitted.
Note for operations
Before operation, ground the operator’s body and perform other
necessary measure against static electricity.
During operations, disconnect the AC cord from the outlet.
After completion of operations, connect the connectors.
After completion of operations, be sure to perform the master
reset.
CHAPTER 2. LIST OF OPTIONS
Master reset (Al l memor y clea r)
There are two possible methods to perform a master reset.
MRS-1
Used to clear all memory contents and return machine back to its initial settings. return keyboard back to default. for default keyboard layout.
Procedure-1 (with SRV key)
1) Unplug the AC cord from the wall outlet.
2) Set the MODE switch to the (SRV) position.
3) Plug in the AC cord to the wall outlet.
4) While holding down JOURNAL FEED key, turn to (SRV) position from (SRV) position.
Procedure-2 (without SRV key)
1) Turn the mode switch to the (REG) position.
2) Ensure the batteries are not installed in the battery compartment and insert the plug into the outlet.
3) The right most decimal point will blink for a few seconds.
4) The register will sound three beeps.
5) The register will display " ."
1. Sales options
No. NAME MODEL DESCRIPTIONS
1 REMOTE DRAWER ER-04DW 5B/8C 2 COIN CASE ER-58CC 5B/8C 3 COIN CASE COVER ER-03CV 4 KEY TOP KIT ER-11KT7 1 × 1 key top
ER-12KT7 1 × 2 key top ER-22KT7 2 × 2 key top ER-11DK7 1 × 1 dummy key ER-51DK7 5 × 1 dummy key
2. Service optio ns
No. NAME PARTS CODE PRICE RANK DESCRIPTIONS
1 SRV KEY LKGIM7113RCZZ AK 2 MODE KEYGRIP COVER LKGIM7126RCZZ AL OP key only 3 DRIP-PROOF KEYBOARD COVER GCÇVH7126BHZZ BE 4 DRIP-PROOF MODE SWITCH COVER GCÇVH7127BHZZ BA 5 SHIELD PLATE KIT DKIT-8666BHZZ BL Only for ER-A330 6 ONE HOLE CASHIER KEY KIT DKIT-8669BHZZ BT 7 DRAWER FIXING KIT DUNT-8670BHZZ AT Only for ER-A330
3. Supplies
No. NAME PARTS CODE PRICE RANK DESCRIPTIONS
1 ROLL PAPER DPAPR1006CSZZ AR 2 INK ROLLER (ER-A310) NRÇLR6652RCZZ AZ 3 INK ROLLER (ER-A330) NRÇLR6638RCZZ AY 4 INK FOR STAMP UINK-1001CCZZ AK
– 1 –
CHAPTER 3. REMOVING THE TOP
5
6
CABINET (For ER-A310 & ER-A330)
1. ER-A310
1) Remove the printer cover 1 .
2) Remove the two screws 2 .
3) Remove the screw 3 and grounding wire 4 .
2
5) Remove transformer cable 5 and drawer cable 6 from the main PWB.
1
2
4) Separate the top cabinet and the drawer unit. Note: Transformer cable 5 and the drawer cable on the drawer
unit are connected to the main PWB on the top cabinet. Be careful when separating them from the drawer unit.
3
4
– 2 –
Loading...
+ 7 hidden pages