ABSOLUTE MAXIMUM RATINGS
(Note 1, 2)
Symb o l Para met er Val u e Unit
V
CC
Supply Voltage 7 V
V
CM
Input Common Mode Range
±
14 V
V
DIFF
Differential Input Voltage
±
14 V
V
IN
Enable Input Voltage 7 V
I
OMAX
Maximum Current per Output ± 25 mA
T
stg
Storage Temperature Range -65 to +150
o
C
Note1: Absolute Maximum Ratings are those values beyond which thesafety of the device cannot be guaranteed. They are notmeant to imply that the
device should be operated at these limits. Thetableof electrical characteristics provide conditions foractual device operation.
Note2:Unlessotherwisespecified,allvoltagearereferenced toground.
RECOMMENDEDOPERATING CONDITIONS
Symbol Parameter Value Unit
V
CC
Supply Voltage 4.5 to 5.5 V
T
A
Operating Temperature Range -40 to +85
o
C
t
r,tf
Maximum Enable Input Rise or Fall Times 500 ns
ELECTRICALCHARACTERISTICS (VCC=5V±10% unless otherwise specified,See Note 1)
Symbol Parameter Test Conditio ns Value Un it
Min. Typ. Max.
V
TH
Minimum Differential Input
Voltage
V
OUT=VOH
or VOL,-7V<VCM< 7V -200 35 200 mV
R
IN
Input Resistance VIN= -7V, 7V Other Input = GND 5 6.8 10 K
Ω
I
IN
Input Current VIN= 10V Other Input = GND 1.1 1.5 mA
V
IN
= -10V Other Input = GND -2 -2.5
V
OH
High Level Output Voltage V
DIFF
=1V, I
OUT
= -6mA 3.8 4.2 V
V
OL
Low Level Output Voltage V
DIFF
=-1V, I
OUT
= +6mA 0.2 0.3 V
V
IH
Minimum Enable High Input
Level Voltage
2V
V
IL
Maximum Enable Low Input
Level Voltage
0.8 V
I
OZ
3-STATE Output Leakage
Current
V
OUT=VCC
or GND
ENABLE = V
IL
ENABLE= V
IH
±0.5 ±5.0 µA
I
I
Maximum Enable Input
Current
VIN=VCCor GND ±1.0 µA
I
CC
Quiescent Power Supply
Current
VCC=Max, V
(DIFF)
=1V 16 23 mA
V
HYST
Input Hysteresis VCM=0V 60 mV
Note1:Unlessotherwisespecified.min/maxlimitsapplyacrosstherecommended operatingtemperature range.
AlltypicalaregivenforV
CC
=5VandTa=25oC
ST26C32A
3/8