SGS Thomson Microelectronics M48T512V, M48T512Y-70PM1, M48T512Y Datasheet

3.3V-5V 4 Mbit (512Kb x8) TIMEKEEPER® SRAM
INTEGRATED ULTRA LOW POWER SRAM,
REAL TIME CLOCK, POWER-FAIL CONTROL CIRCUIT, BATTERY, and CRYSTAL
HOURS, MINUTES, and SECONDS
AUTOMATIC POWER-FAIL CHIP DESELECT
and WRITE PROTECTION
WRITE PROTECT VOLTAGES:
(V
= Power-fail Deselect Voltage)
PFD
– M48T512Y: 4.2V V – M48T512V: 2.7V V
CONVENTIONAL SRAM OPERATION;
UNLIMITED WRITE CYCLES
SOFTWARE CONTROLLED CLOCK
CALIBRATION FOR HIGH ACCURACY APPLICATIONS
10 YEARS of DATA RETENTION and CLOCK
OPERATION in the ABSENCE OF POWER
PIN and FUNCTION COMPATIBLE with
INDUSTRY STANDARD 512K X 8 SRAMS
SELF-CONTAINED BATTERY and CRYSTA L
in DIP PACKAGE
PFD PFD
4.5V 3.0V
32
1
PMDIP32 (PM)
Module
Figure 1. Logic Diagram
V
CC
M48T512Y M48T512V
DESCRIPTION
The M48T512Y/V TIMEKEEPER RAM is a 512Kb x 8 non-volatile static RAM and real time clock or­ganized as 524,288 words by 8 bits. The spe cial DIP package provides a fully integrated battery back-up memory and real time clock solution.
Table 1. Signal Names
A0-A18 Address Inputs DQ0-DQ7 Data Inputs / Outputs E G W V V
CC
SS
Chip Enable Input Output Enable Input Write Enable Input Supply Voltage Ground
19
A0-A18 DQ0-DQ7
W
E
G
M48T512Y M48T512V
V
SS
8
AI02262
1/14December 1999
M48T512Y, M48T512V
Table 2. Absolute Maximum Ratings
Symbol Parameter Value Unit
T
A
T
STG
T
SLD
V
IO
V
CC
I
O
P
D
Note: 1. Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress
2. Soldering temperature not to exceed 260°C for 10 seconds (total thermal budget not to exceed 150°C for longer than 30 seconds).
CAUTION: Negative undershoo ts bel ow –0.3V ar e not al l owed on any pin wh i l e i n the Batter y Back-up mod e.
Ambient Operating Temperature 0 to 70 °C Storage Temperature (VCC Off, Oscillator Off)
(2)
Lead Solder Temperature for 10 seconds 260 °C Input or Output Voltages
Supply Voltage
Output Current 20 mA Power Dissipation 1 W
rating only and functional opera tion of the dev i ce at these or any other conditions above thos e i ndi cated in th e operational section of this spec ification is not im plied. Exposure t o the abso lute max imum rat ing cond itions for extende d period s of tim e may affe ct reliability.
Figure 2. DIP C on ne ctions
(1)
–40 to 85 °C
–0.3 to V M48T512Y –0.3 to 7.0 V M48T512V –0.3 to 4.6 V
CC
+0.3
V
The 32 pin 600 mil DIP Hybrid houses a controller chip, SRAM, quartz crystal, and a long life lithium button cell in a single package. Figure 3 illustrates the static memory array and the quartz con trolled clock oscillator. The clock locations contain the year, month, date, day, hour, minute, and second
A18 V
1
A16
2 3
A14
4
A12
5
A7
6
A6
7
A5
8
A4 A3 A2 A1 A0
DQ0
M48T512Y M48T512V
9 10 11 12 13 14 15
DQ2
16
SS
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
AI02263
CC
A15 A17 W A13 A8 A9 A11 G A10 E DQ7 DQ6 DQ5DQ1 DQ4 DQ3V
in 24 hour BCD format. Corrections for 28, 29 (leap year - compliant until the year 2100), 30, and 31 day months are made automatically. Byte 7FFF8h is the clock control register. This byte con­trols user access to the clock information and also stores the clock calibration setting. The seven clock bytes (7FFFFh-7FFF9h) are not the actual clock counters, they are memory locations consist-
ing of BiPORT™ read/write memory cells within the static RAM array. The M48T512Y/V includes a clock control circuit which updates the clock bytes with current information once per second. Th e in­formation can be accessed by the user in the same manner as any other location in the s tatic memory array. The M48T512Y/V also has its own Power-Fail Detect circuit. This control circuitry constantly monitors the supply voltage for an out of tolerance condition. When V
is out of toler-
CC
ance, the circuit write protects the TIMEKEEPER register data and external SRAM, providi ng data security in the midst of unpredictable system oper­ation. As V
falls, the control circuitry automati-
CC
cally switches to the battery, maintaining data and clock operation until valid power is restored.
The M48T512Y/V directly replaces industry stan­dard 512Kb x 8 SRAMs. It also p rovides the non­volatility of Flash without any requirement for spe­cial write timing or limitations on the number of writes that can be performed.
2/14
READ MODE
The M48T512Y/V is in the Read Mode whenever
(Write Enable) is high and E (Chip Enable) is
W low. The unique address specified by the 19 A d­dress Inputs defines which one of the 524,288 bytes of data is to be access ed. Valid dat a will be available at the D ata I/O pins within Address Ac-
M48T512Y, M48T512V
Table 3. Operating Modes
Mode
Deselect Write Read Read
Deselect Deselect
Note: 1. X = VIH or VIL.
2. See T able 7 for details.
cess T ime (t
AVQV
4.5V to 5.5V
3.0V to 3.6V
V
to V
SO
) after the last address input sig­nal is stable, providing the E are also satisfied. If the E
(1)
V
CC
or
(2)
(min)
PFD
(2)
V
SO
and G access times
and G access times are
E G W DQ0-DQ7 Power
V
IH
V
IL
V
IL
V
IL
X X X High Z CMOS Standby X X X High Z Battery Back-up Mode
not met, valid data will be available after the latter of the Chip Enable Access Times (t Enable Access Time (t
). The state of the eight
GLQV
three-state Data I/O signals is controlled by E G
. If the outputs are activated before t
ELQV
) or Output
and
, the
AVQV
data lines will be driven t o an ind eterminate state until t while E main valid for Output Data Hold Time (t
. If the Address Inputs are changed
AVQV
and G remain active, output data will re-
) but
AXQX
will go indeterminate until the next Address Ac­cess.
WRITE MODE
The M48T512Y/V is in the Wri te Mode whenever
(Write Enable) and E (Chip Enable) are low
W state after the address inputs are stable. The start of a write is referenced from the latter occurring falling edge of W earlier rising edge of W be held valid throughout the cycle. E turn high for a minimum of t or t
from Write Enable prior to the initiation of
WHAX
or E. A write is terminated by the
or E. The addresses must
or W must r e-
from Chip Enable
EHAX
another read or write cycle. Data-in must be valid
prior to the end of write and remain valid for
t
DVWH
t
afterward. G should be kept high during
WHDX
write cycles to avoid bus c ontention; although, if the output bus has been activated by a low on E and G a low on W will disable the outputs t ter W
falls .
WLQZ
af-
X X High Z Standby X
V
IL
V
IH
V
IL
V
IH
V
IH
D
IN
D
OUT
High Z Active
Active Active
Table 4. AC Measurement Conditions
Input Rise and Fall Times 5ns Input Pulse Voltages 0 to 3V Input and Output Timing Ref. Voltages 1.5V
Note that Output Hi-Z is defined as the point where data is no longer driven.
Figure 3. AC Testing Load Circuit
DEVICE UNDER
TEST
CL includes JIG capacitance
650
CL = 100pF
1.75V
AI01803C
3/14
M48T512Y, M48T512V
Figure 4. Block Diagram
OSCILLATOR AND
CLOCK CHAIN
32,768 Hz
CRYSTAL
POWER
LITHIUM
CELL
VOLTAGE SENSE
AND
SWITCHING
CIRCUITRY
V
CC
DATA RETENTION MODE
With valid V
applied, the M48T512Y/V operates
CC
as a conventional BYTEWIDE™ static RAM. Should the supply voltage decay, the RAM will au­tomatically deselect, write protecting itself when V
falls between V
CC
(max), V
PFD
(min) win-
PFD
dow. All outputs become high impedance an d all inputs are treated as "don't care".
Note: A power fa ilure during a writ e cycle may cor­rupt data at the current addressed location, but does not jeopardize the rest of the RAM's content. At voltage s below V in a write protected state, provided the V time is not less than t spond to transient noise s pi kes on V
(min), the memory will be
PFD
. The M48T512Y/V may re-
F
that cr os s
CC
CC
fall
into the deselect window during the time the de­vice is sampling V power supply lines is recomm ended. When V
.Therefore, decoupling of the
CC
CC
drops below VSO, the control circuit switches pow­er to the internal battery, preserving data and pow­ering the clock. The internal energy source will maintain data in the M48T512Y/V for an accumu­lated period of at least 10 years at room tem pera­ture. As system power rises above V
SO
, the
battery is disconnected, and the power supply is
8 x 8
TIMEKEEPER
REGISTERS
A0-A18
DQ0-DQ7
E
W
G
AI02384
V
PFD
524,280 x 8
SRAM ARRAY
V
SS
switched to external VCC. Write protection contin­ues until V Normal RAM operation can resume t exceeds V
reaches V
CC
(max). Refer to Application Note
PFD
(min) plus t
PFD
ER
ER
after V
(AN1012) on the ST Web Site for more information on battery life.
CLOCK OPERATIONS
Reading the Clock Updates to the TIMEKEEPER registers should be halted before clock data is read to prevent reading data in transition. Because the BiPO RT TIMEKEEPER cells in the R AM array are only data registers, and not the actual clock counters, updating the registers can be halted without disturbing the clock itself. Updating is halt­ed when a '1' is written to t he REA D bi t, D6 i n the Control Register (7FFF8h). As long as a '1' re­mains in that position, updat ing is halted. After a halt is issued, the registers reflect the count; that is, the day, date, and time that were current at the moment the halt comm and was issued. All of the TIMEKEEPER registers are updated simulta­neously. A halt will not interrupt an update in progress. Updating occurs 1 second after the READ bit is reset to a '0'.
(min).
CC
4/14
M48T512Y, M48T512V
Table 5. Capacitance
(T
= 25 °C, f = 1 MHz)
A
(1)
Symbol Parameter Test Condition Min Max Unit
C
C
IO
Note: 1. Effective capacitance measured with po wer suppl y at 5V (M48T512Y) or 3.3V (M48T512V ). Sampled only, not 100% tested.
2. Outputs desele cted.
Input Capacitance
IN
(2)
Input / Output Capacitance
V
V
OUT
IN
= 0V
= 0V
20 pF 20 pF
Table 6A. DC Characteristics
= 0 to 70 °C; VCC = 4.5V to 5.5V)
(T
A
Symbol Parameter Test Condition Min Max Unit
(1)
I
LI
I
LO
I
CC
I
CC1
I
CC2
V
V
V
V
OH
Note: 1. Outputs deselected.
Input Leakage Current
(1)
Output Leakage Current Supply Current Outputs open 115 mA
Supply Current (Standby) TTL Supply Current (Standby) CMOS
Input Low Voltage –0.3 0.8 V
IL
Input High Voltage 2.2
IH
Output Low Voltage
OL
Output High Voltage
0V V
IN
0V V
OUT
E
= V
E
= VCC – 0.2V
I
= 2.1mA
OL
I
= –1mA
OH
V
V
IH
CC
CC
±2 µA ±2 µA
8mA 4mA
V
+ 0.3
CC
0.4 V
2.4 V
V
Table 6B. DC Characteristics
= 0 to 70 °C; VCC = 3.0V to 3.6V)
(T
A
Symbol Parameter Test Condition Min Max Unit
(1)
Input Leakage Current
I
LI
(1)
Output Leakage Current
I
LO
I
CC
I
CC1
I
CC2
V
V
V
V
OH
Note: 1. Outputs deselected.
Supply Current Outputs open 60 mA Supply Current (Standby) TTL Supply Current (Standby) CMOS
Input Low Voltage –0.3 0.4 V
IL
Input High Voltage 2.2
IH
Output Low Voltage
OL
Output High Voltage
0V V
IN
0V V
OUT
E
= V
E
= VCC – 0.2V
I
= 2.1mA
OL
I
= –1mA
OH
V
V
IH
CC
CC
±2 µA ±2 µA
4mA 3mA
V
+ 0.3
CC
0.4 V
2.2 V
V
5/14
Loading...
+ 9 hidden pages