Sennheiser SKM 500, SKM 300, SKM 100 Service Manual [en, de]

Service
SKM 100 SKM 300 SKM 500
Part 1
Sennheiser electronic GmbH & Co. KG • D-30900 Wedemark • Tel. 0 51 30 / 600-0 Änderungen vorbehalten / Subject to alterations / Sous réserve de modification
SKM 100, SKM 300, SKM 500
05/00 – 1

TECHNISCHE DATEN

HF-TEIL
Frequenzaufbereitung ________________________________________ Phase-Locked-Loop (PLL)-Synthesizer Frequenzbereiche____________________________________________ 518 ... 550 MHz
630 ... 662 MHz 740 ... 772 MHz 790 ... 822 MHz
838 ... 870 MHz Schaltbandbreite ____________________________________________ max. 32 MHz Kanalanzahl _________________________________________________ SKM 500: 16, SKM 300: 8; SKM 100: 4 Frequenzraster ______________________________________________ 25 kHz HF-Leistung am Antennenausgang ____________________________ 30 mW, -3 dB Modulationsart ______________________________________________ FM Nennhub bei 1 kHz NF _______________________________________±24 kHz Spitzenhub bei 1 kHz NF _____________________________________ ±48 kHz
NF-TEIL
Kompandersystem __________________________________________ HDX NF-Frequenzgang (bei 1 kHz) __________________________________ 100 Hz ... 16 kHz; -3dB Klirrfaktor bei 1 kHz und Nennhub _____________________________ < 0,9% (0,5%) S/N Verhältnis (A-bewertet) ___________________________________ 100 dB
ALLGEMEIN
Nennspannung ______________________________________________ 9 V Betriebsspannung ___________________________________________ 6,0 ... 10 V Stromverbrauch bei Nennspannung ____________________________ 56 mA (52 mA) Ruhestromaufnahme ________________________________________ 100 µA Batterie ____________________________________________________IEC 6 LR 61 (9V Block Alkaline) Betriebsdauer _______________________________________________ 8 Stunden (Varta Nr. 4022 oder 8022) Zulassung __________________________________________________D810 002L RF / FCC ID: DMOH1EURH
SKM 100, SKM 300, SKM 500 05/00 – 2
Änderungen vorbehalten

TECHNICAL DATA

(Values in brackets are typical values)
RF STAGE
RF Generation and control ____________________________________ Phase-Locked-Loop (PLL)-Synthesizer Frequency ranges____________________________________________ 518 ... 550 MHz
630 ... 662 MHz 740 ... 772 MHz 790 ... 822 MHz
838 ... 870 MHz Switching bandwidth_________________________________________ max. 32 MHz Quantity of channels _________________________________________ SKM 500: 16, SKM 300: 8; SKM 100: 4 Channel grid ________________________________________________ 25 kHz RF Power at antenna output __________________________________30 mW, -3 dB Modulation _________________________________________________FM Nominal deviation at 1 kHz AF_________________________________ ±24 kHz Peak deviation at 1 kHz AF____________________________________ ±48 kHz
AF STAGE
Compander system __________________________________________ HDX AF-Frequency response (Ref. 1 kHz) ___________________________100 Hz ... 16 kHz; -3dB THD at 1 kHz and nominal deviation____________________________ < 0.9% (0.5%) S/N A-weighted _____________________________________________ 100 dB
GENERAL
Nominal supply voltage_______________________________________ 9 V Operating voltage ___________________________________________ 6.0 ... 10 V Current consumption at nominal voltage ________________________ 56 mA (52 mA) Stand-by current_____________________________________________ 100 µA Battery _____________________________________________________ IEC 6 LR 61 (9V Block Alkaline) Operating time ______________________________________________ 8 Hours (Varta No. 4022 or 8022) Approbation ________________________________________________ D810 002L RF / FCC ID: DMOH1EURH