Troubleshooting:
Problem:
Deadbolt does not activate when the door closes.
Deadbolt activates when the door is closed, but does not lock the door.
How to reset unit.
For any other problems
Possible cause:
The sensor in the lock body is too far from the magnet in the strike plate.
Deadbolt may not be properly going into the deadbolt hole in the door.
Solutions:
• Try adjusting the strike plate, lock body position, or shims.
• Make sure the deadbolt is going into the hole and not hitting
• If the deadbolt is going into the hole, it may be hitting the bottom of
• Ground the green wire momentarily.
• Substitute a problem unit for a working unit in another door frame
Also Available from SECO-LARM:
Electric Deadbolt
Electric Shear Lock
the strike plate. If not, you must reposition the strike plate.
the hole (if it is in a wooden door). In this case, drill a deeper hole.
to see if it works there.
Electromagnetic Locks
Universal Door Strike
SD-997B-1SQ
Mini Surface-Mount Deadbolt
Manual
SD-997B-GBQ
Fail-safe,
12/24 VDC operation.
With door-position monitoring output.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE:
policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specications
without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM
The information and specications printed in this manual are current at the time of publication. However, the SECO-LARM
®
U.S.A., Inc.
SD-993B-SS
Holding force:
1,500lb (680kg).
Small size for use with
most metal door jambs.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
4
Available with 80, 300,
600, 1,200, or 1,300-lb
holding force. All locks come
with a lifetime warranty.
Website: www.seco-larm.com E-mail: sales
@
seco-larm.com
SECO-LARM U.S.A., Inc.
SD-996C-NUQ
Field selectable fail-safe or
fail-secure operation.
UL listed.
MiSD997B-1SQ_140506.indd
PITSW2
• Fail-safe operation (unlocks if power is lost).
• Surface-mount design for easy installation.
• Magnetic switch senses door position for positive locking.
• Aluminum alloy bolt, 15/32”(12.7mm) diameter, 9/16”(14mm) throw.
• Automatically relocks after 6 seconds if the lock was unlocked but the door was not opened.
• Door open/close monitor (NC/COM).
• Lock delay timer adjustable between 0 and 3 seconds.
• Use with an optional digital keypad for high security without a key.
• Powered by a solenoid.
®
SECO-LARM
Mini Surface-Mount Deadbolt Manual
Mini Surface-Mount Deadbolt Manual
Introduction:
The SECO-LARM Mini Surface-Mount Electric Deadbolts is designed for hollow metal door frames and solid wooden door frames. Its small size makes it easy to add secure, electrical locking to small doors.
Specifications:
Parts List:
Operation Operation voltage
Current draw
Status sensor Adjustable lock delay timer Operating Temperature Weight
1x Lock body 1x Strike body
2x Plate spacer
Standby Active
1x 5-pin connector 6x Mounting screws (M4x40mm)
6x Screw cover stickers
237mA@12VDC max. 650mA@12VDC max.
250mA@30VDC (NC/COM)
0/3 s (default)
32°~158° F (0°~70° C)
1-lb,2.5-oz (450g)
Fail-safe
12VDC
Overview:
Lock body Strike body
Installation:
1.Determine where the deadbolt will be mounted (see g. 1).
2. Adjust the wire output direction based on the selected application and adjust the lock delay time
if necessary (see g. 3).
Adjust the wire output direction
a. Unscrew the 2 screws and remove the cover of the lock body.
b. Remove the wire grommet from the lock body and insert the wires of the 5-pin connector
into the grommet .
c. Plug the 5-pin male connector into the 5-pin socket and adjust the desired wire output direction as shown in g. 3.
Adjust lock delay time
a. The default lock delay time is 3s. To remove the delay time, remove the jumper (see g. 3).
3. Use the screw holes of the lock body and strike body as template and mark the locations of the
screws with a pencil.
4. Secure the lock body and strike body with the 6 included screws. Use 4 screws for the lock body and 2 screws for the strike body. Cover the screw heads with the provided screw cover stickers.
Note: If there’s a gap betweent the lock body and the strike body, use the included 2 plate spacers
to correct the alignment as shown in g. 2.
5. Connect the wires and insulate them (see g. 4):
Plate spacer
a. Red – Power input (+) b. Brown – Power input (-) c. Green – Control wire (-) ground to release bolt d. Blue – Door monitor, COM
e. Purple – Door monitor, N.C. (active when door closed)
Warning :
1. Correct polarity of the red and brown wires is critical. Incorrect polarity will burn out the solenoid.
2. Do not connect a voltage input on the green wire otherwise it will damage the unit.
3. Maximum distance between lock body and strike body must not exceed 6mm.
Fig. 1 – Possible Mounting Locations.
Vertical mount
Horizontal mount
Fig. 2 – Using the Plate Spacers
Lock body
Plate spacer
Strike body
Fig. 3 – Adjusting the Lock Delay Time / Wire Output Direction.
Lock delay jumper
5-Pin Socket
Fig. 4 –Wiring Diagram
Jumper
Adjust wire grommet for
different wire output direction
5-Pin Connector
Card reader or keypad
COM
N.C. N.O.
Green wire (Control wire) Brown wire (-) Red wire (+)
Purple wire (Door Monitor, N.C.) – active if door is locked Blue wire (Door Monitor, COM) – manual lock/unlock
ON
OFF
Delay Time
3s (default)
0s
Request-to-Exit
pushbutton
12VDC Power Supply
2
SECO-LARM U.S.A., Inc. SECO-LARM U.S.A., Inc.
3
Loading...