Seco-Larm SD-997A-GBQ User Manual

Installation Manual
SD-997A-GBQ - Fail-Secure,12/24VDC SD-997BQ - Fail-Safe,12VDC SD-997B-GBQ - Fail-Safe,12/24 VDC
Electric Deadbolt
SECO-LARM Electric Deadbolts are designed for hollow metal door frames. They are not recommended for wooden door frames. However, door can be wood or metal.
Features
• Adds concealed deadbolt security to most wood or hollow metal doors, with the convenience of electrical operation.
• Stainless steel bolt, 5/8” diameter, 5/8” throw.
• SD-997A-GBQ – Fail-secure operation (locks if power is lost).
• SD-997B Series – Fail-safe operation (unlocks if power is lost).
• Magnetic switch senses door position for positive locking.
• Attempts to relock multiple times if the door is not closed properly (SD-997A-GBQ & SD-997B-GBQ only).
• Door open/close monitor (NO/C/NC).
• Adjustable door lock delay timer - see Specifications.
• Use with an optional digital keypad for high security without a key.
• Easily connects to SECO-LARM’s Digital Access Keypad.
• Suitable for office-type applications.
• Optional mounting brackets available.
• Shallow design for use with most metal door jambs.
• Powered by a solenoid.
• Stainless steel for strength and long life.
3
/
4
(19.3mm)
1
/
8
4
(105mm)
5
/8
Fig. 1 - Possible Mounting Locations
Important - For vertical mounting of SD-997B series only, wires must come out
the top of the unit.
For single door
Mounting Location
Can be mounted opposite the door hinges, or on the header or on top of the door away from the hinges. Mounting on the bottom of the door is not recommended because of the possibility of dirt and dust buildup. (see fig. 1)
(16mm) Throw
1
(57.5mm)
/
2
4
SD-997B series shown
For single door For double doors
3
/
4
(19mm)
1
/
2
1
(37.5mm)
1
/
8
(3.5mm)
6
SD-997B series
3
/
(162mm)
8
Dimensions:*
*Note: Original measurements taken in millimeters. Inches are closest 1/16” approximation.
Page 1
Electric Deadbolt Installation Manual
Fig. 2 - Parts List:
Lock body x 1
or
SD-997BQ/
SD-997A-GBQ
Strike
Plate x 1
Installation
1. Determine where the deadbolt will be mounted (see fig. 1).
2. Tape the templates to the door frame and door (see fig. 3)
A. Align the templates so that the deadbolt of the lock body template
is centered on the deadbolt hole of the strike plate template.
B. Make sure to leave enough room at the ends of the lock body
and strike plate templates for mounting the mounting tabs.
3. Door frame cut (see fig. 4)
A. Cut out the space for the lock body. B. Test the fit. The lock body should fit snugly inside the space. C. Drill two 5mm screw holes as shown on the
4. Door cut and mount. (see fig. 4)
A. For wood doors:
1) Use a chisel to knock out a 3mm (1/8-inch) deep space as shown on the template.
2) Drill the magnet hole, 12mm (1/2”) wide by 6mm (1/4”) deep.
3) Use four wood screws to mount the strike plate in the chiseled space. The magnet should fit in the magnet hole.
4) Use a drill to drill out the deadbolt hole to a depth of 16mm (5/8”).
B. For hollow metal doors:
1) Cut out the space for the strike plate.
2) Drill two screw holes for each of the two mounting tabs.
3) Use screws to fix the mounting tabs inside the hollow metal door.
4) Use screws to fix the strike plate to the mounting tabs.
5. Door jamb cut and mount (see fig. 4) A. Cut out the space for the face of the lock body.
B. Drill one 5mm hole for each of the two mounting tabs. C. Use screws to fix the mounting tabs inside the door jamb. D.
SD-997A-GBQ only: Insert the lock/unlock cylinder (see fig. 5).
E. Connect the wires, and insulate them (see fig. 7):
1) Red – Power input (+)
2) Brown – Power input (-)
3) Orange – Control wire (ground to release bolt)
4) Green – Door monitor, COM
5) Yellow – Door monitor, N.C. (active when door closed)
{
*
6) Blue – Door monitor, N.O. (active when door open)
IMPORTANT – Correct polarity of the red and brown wires is critical. Incorrect polarity will burn out the solenoid !
*
Connect to an alarm control panel or warning device to show if the door is open or closed.
Page 2
SD-997B-GBQ
Mounting tabs (large) x 2
Mounting tabs (small) x 2
template.
SD-997A-GBQ Also Includes:
Manual lock/unlock cylinder x 1
Faceplate x 1
Oval cylinder plate x 2
6-Pin
connector x 1
Templates x 4
Mounting screws
Keys x 3
connector x 1
Fig. 3 - Aligning
Lock body template
Strike plate template
Line up these marks
IMPORTANT – Push all the wires into the door frame. If space is a problem, cut away part of the dust catcher inside the frame, or carefully chip away part of the drywall, being careful not to damage the wall.
F. Set the door lock delay timer (see fig. 8). This is the
time it takes the deadbolt to automatically lock after the door is closed.
NOTE: For SD-997A-GBQ & SD-997B-GBQ only – The
deadbolt automatically relocks 4 seconds after an optional external push button (egress button) is pressed, if the door was not opened.
The lock body has a sensor mechanism wherein it can detect if the strike plate is in close proximity (such as when the door is closed). If the door was closed but somehow the strike plate was not aligned properly, the door monitor indicator may indicate that the
SECO-LARM U.S.A., Inc.
3-Pin
Electric Deadbolt Installation Manual
door is closed but the deadbolt remains unlock. During this time the lock body may attempt multiple times to relock the door and if it fails, it will stop to prevent the solenoid from burning out.
However if the lock body and the strike plate are too far apart, the lock body will not attempt to lock the door and the deadbolt will not throw out.
IMPORTANT – The lock body and strike plate must be properly aligned and next to each other in order for the product to function properly.
G.
Pull the vinyl covering off the faceplate, and place the faceplate over the face of the lock body. Use screws to fix the faceplate and lock body to the mounting tabs.
Fig. 4 - Door and Frame Cuts
Max. 50mm
SD-997A-DQ
only*
*
See separate
template.
Door frame
Door
Fig. 5 - Manual Lock/Unlock Cylinder (SD-997A-GBQ only):
Note:
If cylinder is used, max. depth of door frame is 50mm.
6. For SD-997A-GBQ only (see figs. 5 and 6) Because the SD-997A-GBQ offers fail-secure operation, the door locks if power to the unit is cut. For such a situation, a separate manual lock/unlock cylinder is provided for manual operation. A. Insert the cylinder as shown in Fig. 5, and secure it to the
lock body with the provided long screw. Turning the key or the manual knob will unlock the SD-997A-GBQ manually.
B. Two separate templates are included for drilling holes in the
door frame for the key and manual knob.
C. A separate 3-pin connector for the SD-997A-GBQ can be
connected to an alarm panel or annunciator to alert when the door is locked or unlocked.
Fig. 7 - Wiring
N.C. N.O.
SD-997A-GBQ/SD-997B series
See fig. 8
Red wire
Green wire - door monitor, COM
Blue wire - door monitor, N.O.
Yellow wire - door monitor, N.C. (active when door closed)
Purple wire - active if door is locked (N.C.)
Gray wire - manual lock/unlock
Black wire - active if door is unlocked
IMPORTANT – Do not cut wires before the plug as warranty
will be voided.
COM
Orange
Brown wire
(COM)
Card reader or keypad
(active when door open)
{
For
(N.O.)
SD-997A-GBQ only
Fig. 8 - Setting Door Lock Delay Timer
SD-997A-GBQ
Push
button
Power Supply
Screw to secure
cylinder to lock
body
SD-997BQ / SD-997B-GBQ
Fig. 6 - Installation of Manual Lock/Unlock Cylinder (SD-997A-GBQ only):
Installation at side of door
Drill hole for lock
SECO-LARM U.S.A., Inc.
Drill hole for lock
Installation at top of door
Drill hole for lock
Drill hole for lock
Page 3
Electric Deadbolt Installation Manual
Specifications
Operation Operation voltage
Current draw
Status sensor Adjustable delay timer Weight (approx.)
Standby Active
SD-997A-GBQ
Fail-secure
12/24 VDC 330mA@12VDC/205mA@24VDC 880mA@12VDC/470mA@24VDC
SPDT, 250mA @ 12VDC (NO/NC/COM)
0/3/5/9 secs.
2-lbs,5-oz (1kg)
SD-997B-GBQ
12/24 VDC 340mA@12VDC/180mA@24VDC 900mA@12VDC/440mA@24VDC
Troubleshooting:
Problem:
Deadbolt does not activate when the door closes.
Deadbolt activates when the door is closed, but does not lock the door.
How to reset unit.
For any other problems
Possible cause:
The sensor in the lock body is too far from the magnet in the strike plate.
Deadbolt may not be properly going into the deadbolt hole in the door.
Solutions:
• Try adjusting the strike plate, lock body position, or shims.
• Make sure the deadbolt is going into the hole and not hitting the strike plate. If not, you must reposition the strike plate.
• If the deadbolt is going into the hole, it may be hitting the bottom of the hole (if it is in a wooden door). In this case, drill a deeper hole.
• When testing, if necessary, reset the unit by grounding the orange wire momentarily.
• Replace the unit, and test again. A problem unit can also be substituted for a working unit in another door frame to see if it works there.
Optional Mounting Brackets Available for SD-997B Series
Surface-Mount Bracket
:
SD-997SMB-AQ
Mount the deadbolt and strike plate on the door jamb instead of in the door frame.
“U” Bracket
SD-997UB-AQ
Mount the deadbolt and strike plate on glass doors.
SD-997BQ
Fail-safe
12VDC
0/2.5/5/9 secs.
1-lb,13-oz (0.8kg)
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a
period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2015 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
®
SECO-LARM
U.S.A., Inc.U.S.A., Inc.
U.S.A., Inc.
U.S.A., Inc.U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 4
MI_SD997x-xxQ_151102.pmd
Website: www.seco-larm.com
@
E-mail: sales
seco-larm.com
SECO-LARM U.S.A., Inc.
PITSW2
Loading...