Seco-Larm SD-997A-GBQ User Manual

Installation Manual
SD-997A-GBQ - Fail-Secure,12/24VDC SD-997BQ - Fail-Safe,12VDC SD-997B-GBQ - Fail-Safe,12/24 VDC
Electric Deadbolt
SECO-LARM Electric Deadbolts are designed for hollow metal door frames. They are not recommended for wooden door frames. However, door can be wood or metal.
Features
• Adds concealed deadbolt security to most wood or hollow metal doors, with the convenience of electrical operation.
• Stainless steel bolt, 5/8” diameter, 5/8” throw.
• SD-997A-GBQ – Fail-secure operation (locks if power is lost).
• SD-997B Series – Fail-safe operation (unlocks if power is lost).
• Magnetic switch senses door position for positive locking.
• Attempts to relock multiple times if the door is not closed properly (SD-997A-GBQ & SD-997B-GBQ only).
• Door open/close monitor (NO/C/NC).
• Adjustable door lock delay timer - see Specifications.
• Use with an optional digital keypad for high security without a key.
• Easily connects to SECO-LARM’s Digital Access Keypad.
• Suitable for office-type applications.
• Optional mounting brackets available.
• Shallow design for use with most metal door jambs.
• Powered by a solenoid.
• Stainless steel for strength and long life.
3
/
4
(19.3mm)
1
/
8
4
(105mm)
5
/8
Fig. 1 - Possible Mounting Locations
Important - For vertical mounting of SD-997B series only, wires must come out
the top of the unit.
For single door
Mounting Location
Can be mounted opposite the door hinges, or on the header or on top of the door away from the hinges. Mounting on the bottom of the door is not recommended because of the possibility of dirt and dust buildup. (see fig. 1)
(16mm) Throw
1
(57.5mm)
/
2
4
SD-997B series shown
For single door For double doors
3
/
4
(19mm)
1
/
2
1
(37.5mm)
1
/
8
(3.5mm)
6
SD-997B series
3
/
(162mm)
8
Dimensions:*
*Note: Original measurements taken in millimeters. Inches are closest 1/16” approximation.
Page 1
Electric Deadbolt Installation Manual
Fig. 2 - Parts List:
Lock body x 1
or
SD-997BQ/
SD-997A-GBQ
Strike
Plate x 1
Installation
1. Determine where the deadbolt will be mounted (see fig. 1).
2. Tape the templates to the door frame and door (see fig. 3)
A. Align the templates so that the deadbolt of the lock body template
is centered on the deadbolt hole of the strike plate template.
B. Make sure to leave enough room at the ends of the lock body
and strike plate templates for mounting the mounting tabs.
3. Door frame cut (see fig. 4)
A. Cut out the space for the lock body. B. Test the fit. The lock body should fit snugly inside the space. C. Drill two 5mm screw holes as shown on the
4. Door cut and mount. (see fig. 4)
A. For wood doors:
1) Use a chisel to knock out a 3mm (1/8-inch) deep space as shown on the template.
2) Drill the magnet hole, 12mm (1/2”) wide by 6mm (1/4”) deep.
3) Use four wood screws to mount the strike plate in the chiseled space. The magnet should fit in the magnet hole.
4) Use a drill to drill out the deadbolt hole to a depth of 16mm (5/8”).
B. For hollow metal doors:
1) Cut out the space for the strike plate.
2) Drill two screw holes for each of the two mounting tabs.
3) Use screws to fix the mounting tabs inside the hollow metal door.
4) Use screws to fix the strike plate to the mounting tabs.
5. Door jamb cut and mount (see fig. 4) A. Cut out the space for the face of the lock body.
B. Drill one 5mm hole for each of the two mounting tabs. C. Use screws to fix the mounting tabs inside the door jamb. D.
SD-997A-GBQ only: Insert the lock/unlock cylinder (see fig. 5).
E. Connect the wires, and insulate them (see fig. 7):
1) Red – Power input (+)
2) Brown – Power input (-)
3) Orange – Control wire (ground to release bolt)
4) Green – Door monitor, COM
5) Yellow – Door monitor, N.C. (active when door closed)
{
*
6) Blue – Door monitor, N.O. (active when door open)
IMPORTANT – Correct polarity of the red and brown wires is critical. Incorrect polarity will burn out the solenoid !
*
Connect to an alarm control panel or warning device to show if the door is open or closed.
Page 2
SD-997B-GBQ
Mounting tabs (large) x 2
Mounting tabs (small) x 2
template.
SD-997A-GBQ Also Includes:
Manual lock/unlock cylinder x 1
Faceplate x 1
Oval cylinder plate x 2
6-Pin
connector x 1
Templates x 4
Mounting screws
Keys x 3
connector x 1
Fig. 3 - Aligning
Lock body template
Strike plate template
Line up these marks
IMPORTANT – Push all the wires into the door frame. If space is a problem, cut away part of the dust catcher inside the frame, or carefully chip away part of the drywall, being careful not to damage the wall.
F. Set the door lock delay timer (see fig. 8). This is the
time it takes the deadbolt to automatically lock after the door is closed.
NOTE: For SD-997A-GBQ & SD-997B-GBQ only – The
deadbolt automatically relocks 4 seconds after an optional external push button (egress button) is pressed, if the door was not opened.
The lock body has a sensor mechanism wherein it can detect if the strike plate is in close proximity (such as when the door is closed). If the door was closed but somehow the strike plate was not aligned properly, the door monitor indicator may indicate that the
SECO-LARM U.S.A., Inc.
3-Pin
Loading...
+ 2 hidden pages