ENFORCER Post-Mount No Touch Sensor with Access Box
Sensor and LED Adjustment
s special care to ensure reliability and a long operating life.
Incorrect mounting which leads to exposure to rain or moisture inside the enclosure could cause a dangerous
The information and specifications printed in this manual are current
at the time of publication.
LARM product is warranted against defects in
material and workmanship while
16842 Millikan Avenue, Irvine, CA 92606
MiSD-9963-KSGQ_141022.docx
Adjusting the sensor range and trigger time:
Care and Cleaning for the SD
Touch Sensor with Access Box
1. The sensor range can be adjusted 2”~7” (5~18 cm).
2. The trigger time can be adjusted from 0.8 to
30 seconds or toggle
1
.
Jumper Placement:
Trigger: Red
NOTE: Do not force the adjustment trimpots
to turn. Only minimal force is needed.
Sensor range: 2”~7” (5~18 cm)
Default: 7” (18cm)
adjustment
1
Default: 0.8 seconds
1
Toggle: turn all the way clockwise to maximum
1. Use a soft, clean cloth for cleaning. Use the mildest type of cleaner available.
2. When cleaning, spray the cleaning solution onto the cleaning cloth instead of the unit.
3. Be sure to wipe off any excess liquid from the sensor. Wet spots or areas may affect the sensor’s
performance.
adjustment
Trigger: Green
SD-9963-KSGQ
Post-Mount No Touch Sensor
with Access Box
Manual
electric shock, damage the device, and void the warranty.
service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
4 SECO-LARM U.S.A., Inc.
®
U.S.A., Inc.
®
which uses IR technology to allow egress from a protected area or activate a device with the
simple wave of a hand. Since it is touchless, this sensor is ideal for use in hospitals, clinics, labs,
cleanrooms (to reduce the risk of contamination), schools, factories, or offices where no special
clearance is required for exit or where a longer range sensor may cause unwanted activation. A
manual override button is also provided.
PITSW1
ENFORCER Post-Mount No Touch Sensor with Access Box
1. Run four wires through the wall to
Typical installation with an electric lock:
ENFORCER Post-Mount No Touch Sensor with Access Box
• Adjustable sensor range up to 7" (18cm)
• Weather resistant for outdoor use
• Stainless steel plate
• Hinged plate easily removes from box for easy
wiring
• 1A Relay, adjustable trigger duration 0.8~30
seconds or toggle
• Dual voltage: 12/24VDC
Current
drain (max.)
LEDs
1
• Gooseneck- or wall-mountable
• Manual override button
• LED-illuminated sensor area for easy
identification
• Selectable LED colors (turns from red to green
or green to red) on sensor activation
• Includes heavy-duty steel box
16mA@12VDC / 25mA@24VDC
25mA@12VDC / 32mA@24VDC
Form C dry contact, 1A@30VDC
10ms
Red1
Green1
0.8~30 s or toggle
2”~7” (5~18 cm)
IP652
-4°~131° F (-20°~55° C)
1-lb 9-oz (710g)
4”x5½”x3” (102x134x77 mm)
COM: N.O.
no further wiring necessary
(-)
button
(125mm)
Form C mechanical override
button
2 SECO-LARM U.S.A., Inc.
2. Unlock and remove the front plate from the access box.
3. Install the access box to the wall through the four mounting holes in the back, and thread the
four wires through the center hole.
4. Replace the front plate, but leave open and connect the four wires from the access box to the
no-touch sensor according the wiring diagram above.
5. Close and lock the front plate, taking care not to crimp the wires.
6. Remove clear protective film from the sensor before use.
7. Make a copy of the key in case of loss. SECO-LARM does not offer replacement keys.
WARNING: Do not connect any device that will exceed 1A@30VDC.
SECO-LARM U.S.A., Inc. 3