Seco-Larm SD-9963-KSGQ User Manual

ENFORCER Post-Mount No Touch Sensor with Access Box
Sensor and LED Adjustment
:
The sensor require
s special care to ensure reliability and a long operating life.
WARNING:
Incorrect mounting which leads to exposure to rain or moisture inside the enclosure could cause a dangerous
NOTICE
:
The information and specifications printed in this manual are current
at the time of publication.
However, the
WARRANTY:
This SECO
-
LARM product is warranted against defects in
material and workmanship while
used in normal
SECO
-
LARM
16842 Millikan Avenue, Irvine, CA 92606
Website:
www.seco
-
larm.com
Phone: (949) 261
-
2999 | (800) 662
-
0800 Email: sales@seco
-
larm.com
Order Part#
763-182%
MiSD-9963-KSGQ_141022.docx
Trigger time
Sensor range
Standby
: Green
Standby
: Red
Changing
the LED Color
Trigger time: 0.
8~3
0 seconds, toggle
Adjusting the sensor range and trigger time:
Care and Cleaning for the SD
-9963-K
SGQ
Sensor
:
The ENFORCER
Post-Mount
No
Touch Sensor with Access Box
is a full
-
featured exit plate
1. The sensor range can be adjusted 2”~7” (5~18 cm).
2. The trigger time can be adjusted from 0.8 to
30 seconds or toggle
1
.
Jumper Placement:
Trigger: Red
NOTE: Do not force the adjustment trimpots
to turn. Only minimal force is needed.
Sensor range: 2”~7” (5~18 cm)
Default: 7” (18cm)
adjustment
1
Default: 0.8 seconds
1
Toggle: turn all the way clockwise to maximum
1. Use a soft, clean cloth for cleaning. Use the mildest type of cleaner available.
2. When cleaning, spray the cleaning solution onto the cleaning cloth instead of the unit.
3. Be sure to wipe off any excess liquid from the sensor. Wet spots or areas may affect the sensor’s
performance.
adjustment
Trigger: Green
SD-9963-KSGQ
Post-Mount No Touch Sensor
with Access Box
Manual
electric shock, damage the device, and void the warranty.
service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
4 SECO-LARM U.S.A., Inc.
®
U.S.A., Inc.
®
which uses IR technology to allow egress from a protected area or activate a device with the simple wave of a hand. Since it is touchless, this sensor is ideal for use in hospitals, clinics, labs, cleanrooms (to reduce the risk of contamination), schools, factories, or offices where no special clearance is required for exit or where a longer range sensor may cause unwanted activation. A manual override button is also provided.
PITSW1
ENFORCER Post-Mount No Touch Sensor with Access Box
Power
12/
24
VDC
Standby
Triggered
Relay type
Response time
Standby
Triggered
Output time
Range
IP Rating
Temperature range
Weight
Size
Color function
reversible
2Front panel only
Specifications
:
Parts List:
1x Touchless sensor
1x
Steel a
ccess box
4x Mounting screws
2x
Key 1x
Manual
Overview:
415/16”
37/8” (98m
m)
Locking m
echanism
Sensor
r
ange
a
djustment
Trigger
t
ime adjustment
LED control
j
umper
5-pin connector
Features
:
Sample
Wiring
Diagram
:
Red Wire: +12~24 VDC
Brown Wire: Ground
Blue Wire: COM
Purple Wire: N.O.
Green Wire: N.C.
Installation:
1. Run four wires through the wall to
the a
ccess
box.
Blue Wire: COM
Purple Wire: N.O.
Brown Wire: Ground (
-)
Red Wire: +12~24 VDC
Override button is
factory
prewired
,
Manual
o
verride
Typical installation with an electric lock:
Green Wire: N.C.
ENFORCER Post-Mount No Touch Sensor with Access Box
Adjustable sensor range up to 7" (18cm)
Weather resistant for outdoor use
Stainless steel plate
Hinged plate easily removes from box for easy
wiring
1A Relay, adjustable trigger duration 0.8~30
seconds or toggle
Dual voltage: 12/24VDC
Current drain (max.)
LEDs
Gooseneck- or wall-mountable
Manual override button
LED-illuminated sensor area for easy
identification
Selectable LED colors (turns from red to green
or green to red) on sensor activation
Includes heavy-duty steel box
16mA@12VDC / 25mA@24VDC 25mA@12VDC / 32mA@24VDC Form C dry contact, 1A@30VDC
10ms
Red1
Green1
0.8~30 s or toggle 2”~7” (5~18 cm)
IP652
-4°~131° F (-20°~55° C) 1-lb 9-oz (710g)
4”x5½”x3” (102x134x77 mm)
COM: N.O.
no further wiring necessary
(-)
button
(125mm)
Form C mechanical override
button
2 SECO-LARM U.S.A., Inc.
2. Unlock and remove the front plate from the access box.
3. Install the access box to the wall through the four mounting holes in the back, and thread the
four wires through the center hole.
4. Replace the front plate, but leave open and connect the four wires from the access box to the
no-touch sensor according the wiring diagram above.
5. Close and lock the front plate, taking care not to crimp the wires.
6. Remove clear protective film from the sensor before use.
7. Make a copy of the key in case of loss. SECO-LARM does not offer replacement keys. WARNING: Do not connect any device that will exceed 1A@30VDC.
SECO-LARM U.S.A., Inc. 3