EXP = External module connector
OK = Programming button
DOWN = Programming button
UP = Programming button
RD1 =Motors piloting Mosfet
RD3 = Motors piloting Mosfet
R1 = Motors command relay
R2 = Motors command relay
PR1 = Rectifier jumper
F1 = Fuse 6.3 AT
JOLLY-JOLLY2
CN2
1
®
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
POWER (CN8)
MOTOR (CN6)
English
CONNECTIONS
LIGHT (CN5)
ENCODER (CN4)
USER 1 - 24V DG R1
For garage door
LIMIT SWITCH (CN2)
24V (Red)
Limit switch Cl.1 (Yellow)
24V~
M
Max 200W
2
1
ANT COM START
Antenna
34
Start
Common
Max 100mA
56
PEDST
STOP COMPH1 PH2
Stop
Common
START Ped.
CN1
78
Photocell 1
On Master-Slave
connector
9
10
EDGE
AUX
++
AUX
Photocell 2
Safety edge
Limit switch Op.1 (Green)
Common (White)
12
11
COM 24V(FL)-
--
Common
(24V 200 mA max)
13
(Accessories)
24V 750 mA max
1
Flash (-)
JUMPERS
WARNING: The control unit is designed with the automatic detection of not used N.C. inputs (photocells, Stop and Limit switch) except the
SAFETY EDGE input. The exclude inputs in self-programming can be restored in the “Check inputs” menu without need to repeat the
programming (pag.27).
CN1
2
1
ANT COM START
Antenna
Obligatory jumper without accessory connection.
Optional
Common
34
PEDST
Start
56
STOP COMPH1 PH2
Stop
START Ped.
Common
78
Photocell 1
Photocell 2
9
EDGE
Safety edge
10
11
AUX
COM 24V(FL)-
++
AUX
--
Common
(24V 200 mA max)
12
13
Flash (-)
(Accessories)
24V 750 mA max
The herein reported functions
are available starting from
revision 46.
67411370REV 03 - 11/2014
19
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
English
USER 1 - 24V DG R1
For garage door
PROGRAMMING
MENU
1
MENU
2
MENU
3
MENU
4
UP
SEA
SET
LANGUAGE
UP
SEA
SET
TRANSMITTERS
UP
SEA
SET
MOTOR
UP
SEA
SET
REVERSE
MOTOR
UP
OK
OK
If on the display
appears the item:
OK
QUICK START
SEA
MENU
ITALIANO
Skip this step if you do not want to program a transmitter
MENU
START
Choose "ON" with UP or
programming the motor starts
SET
SEA
SET
MENU
OK
SEA
MENU
RECEIVER
MISSING
Choose the type of
motor with
UP or DOWN
DOWN button only if in
in opening
Check if a receiver has
SET
been connceted
(see page 18)
SEA
PRESS
BUTTON
OKOK
SET
Press the
button of the
TX to be
stored
To confirm and return
to main menu
Return to menu 7,
OK
place the gate halfway
the times programming
and repeat
PROGRAMMING
BUTTONS
DOWNUP
SEA
MENU
SET
STORED
If the motor has
magnetic limit switches,
select "Magnetic"
in the special menu:
34-Limit switch type
OK to exit
Menu or press
the button of
the next TX to
be stored
OK
5
(See
page 21)
6
7
8
(See
page 21)
9
SEA
MENU
SET
LOGIC
UP
SEA
MENU
SET
PAUSE TIME
UP
SEA
MENU
SET
START IN
PAUSE
UP
SEA
MENU
SET
PROGRAM-
MING
UP
SEA
MENU
SET
TEST START
With UP or DOWN
OKOK
choose
To confirm and return
the desired logic
OKOK
choose a delay for
With UP or DOWN
To confirm and return
automatic closing
OKOK
With UP or DOWN
To confirm and return
Choose ON
OKOK
With UP or DOWN choose ON
to start times learning
The gate will execute a CLOSING-OPENING-CLOSING CYCLE
Skip this step if a TX has already been stored
OKOK
UP or DOWN Choose
With
ON to start test
to main menu
to main menu
to main menu
At the end of the selflearning
the control unit returns automatically
To confirm and return to
Skip this step
if you wna tto work
in half-automatic
logic
to the main menu
main menu
ALL OTHER PARAMETERS HAVE DEFAULT SETTINGS WHICH ARE USEFUL FOR THE 90% OF THE APPLICATIONS
BUT CAN BE HOWEVER SET THROUGH THE SPECIAL MENU. FOR ENTERING INTO THE SPECIAL MENU MOVE
ON ONE OF THE MENU AND PRESS THE UP AND DOWN BUTTONS AT THE SAME TIME FOR 5 S.
20
67411370
REV 03 - 11/2014
UPDOWN
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
English
USER 1 - 24V DG R1
For garage door
MENU FUNCTIONS TABLE USER1 24V DG R1
MENU
1 - langvage
U
2 - trans tters
U
3 - otor
U
4 - reuerse otor
5 - log (
(See page 22)
U
6 - paVse t e
7 - starT n pavse
U U
8 - progra ng
(See page 22)
SET
tal ano
engl sk
fran(a s
espanol
dut(k
start
Pedestr an Start
U
External odvle
stop
U
Delete a trans itter
UU
(Lear e ory
(Orona 60
(Orona 110
off
on
U
Avto at (
open-stop-(lose-stop-open
open-stop-(lose-open
2 bvttons
safety
U
Dead an
off
1,2,3
off
on
Off on
Description
Italian
English
French
Spanish
Dutch
Start
Pedestrian Start
External module
Stop
Delete single transmitter
Delete transmitter memory
Light garage and
sectional door
Heavy garage and
sectional door
Synchronized right motor
Synchronized left motor
Automatic
Step by step type 1
Step by step type 2
Two buttons
Safety
Dead man
Disabled
Setting from 1s to 4min.
In pause start is not acceped
In pause start is accepted
Times learning start
Default
tal ano
start
Ped Start.
(Orona 60
off
U
Avto at (
off
off
off
Set value
9 - test start
end
67411370
Off on
Start command
Select END and press OK to exit the menu.The menu
deactivates automatically after 2 minutes
REV 03 - 11/2014
off
21
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
English
USER 1 - 24V DG R1
For garage door
WORKING TIMES SELF LEARNING
NOTE: During installation, you can move the door entering the menu "Check inputs" and pressing OK + UP or OK +
DOWN.
1) Place the door halfway.
2) Connect the control board to the power supply.
3) Select on the on-board display or JOLLY programmer, the type of motor that you are using as indicated in the dispaly
administration.
4) Set the motor torque, the working speed, the deceleration and acceleration space and the slowdown speed. If necessary also
set the working logic and the other parameters.
5) Select 8-PROGRAMMING on the display, press OK and than one of the UP or DOWN buttons. Now the gate will automatically
execute a closing, and will restart automatically in opening.
6) In opening press the UP or DOWN button or START (also from TX) at the point where you want to have the maximum opening;
the motor will restart automatically in closing and reveals automatically the closing.
7)The self-learning is done.
Note: If the motor starts in opening, remove and re-put power supply, select on the display 4-REVERSE MOTOR. And through
the UP and DOWN button put it on ON, or if you have the Jolly programmer, activate the motor exchange function. If the motor
starts in closing and stops, remove the power supply and reverse the motor cables, then repeat starting from point 5.
ATTENTION: This procedure is potentially dangerous and should only be performed by qualified personnel in safety
conditions.
The control unit is pre-set with the default settings, to start the control unit with the DEFAULT settings
just keep pressed the UP and DOWN buttons at the same time power supplying the control unit the
display shows the message init.
The DEFAULT settings are shown in the Menues table.
FUNCTION LOGIC
AUTOMATIC LOGIC
A start impulse opens the gate. A second impluse during the opening will not be accepted.
A start impulse during closing reverses the movement.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semi-automatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item 7-START IN
PAUSE and choosing ON or OFF. By default, the parameter is OFF.
SECURITY LOGIC
A start impulse opens the gate. A second impulse during opening reverses the movement.
A start impulse during closing reverses the movement.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semi-automatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item 7-START IN
PAUSE and choosing ON or OFF. By default, the parameter is OFF.
STEP BY STEP TYPE 1 LOGIC
The start impulse follows the OPEN-STOP-CLOSE-STOP-OPEN logic.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semi-automatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item 7-START IN
PAUSE and choosing ON or OFF. By default, the parameter is OFF.
STEP BY STEP TYPE 2 LOGIC
The start impulse follows the OPEN-STOP-CLOSE -OPEN logic.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semi-automatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item 7-START IN
PAUSE and choosing ON or OFF. By default, the parameter is OFF.
DEAD MAN LOGIC
The gate opens as long as the START button of opening is pressed; releasing it the gate stops. The gate closes as long as the
button connected to the PEDESTRIAN START is pressed; releasing it the gate stops. To execute complete opening and/or
closing cycles the related pushbuttons must be constantly pressed.
2 PUSHBUTTONS LOGIC
One start opens, one pedestrian start closes. In opening the closing will not be accepted. In closing a start command reopens, a
pedestrian start command (closes) will be ignored.
22
67411370
REV 03 - 11/2014
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
English
USER 1 - 24V DG R1
For garage door
SPECIAL MENU
PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU
UPDOWN
SPECIAL MENU FUNCTIONS TABLE USER 1 24V DG R1
For entering into the special menu move on one of the menu and press the
buttons at the same time for 5 s. For exiting the special menumove on one of the
menu and press the buttons at the same time for 5 s.
UP and DOWN
press END or
UP and DOWN
MENU SP
1 - speed
2 - sloudoun speed
3 - learn ng speed
4 - open ng torq
5 - (los ng torq
6 - open ng sloudoun
7 - (los ng sloudoun
8 - preflasx ng
9 - flasx ng l gxt
SET
30 100
30 100
30 100
10 100
10 100
Off
5 100
Off
5 100
Only (los ng
0.0 5.0
U
Nor al
L gxt
aluays
bvzzer
Description
Setting from 30 to 100
Setting from 30 to 100
Setting from 30 to 100
Setting from 10 to 100
Setting from 10 to 100
Disabled
Setting from 5 to 100
Disabled
Setting from 5 to 100
Pre-flashing active only
before closing
Pre-flashing time
Normal
Control lamp
Always ON
Buzzer
Default
* 80
* 40
* 80
* 70
* 70
* 30
* 30
Off
U
Nor al
Set Value
10 - (ourtesy l gxt
11 - traff ( l gxt reseruat on
12 - pedestr an open ng
13 - pedestr an PAUSE
14- a((elerat on
U
15 - a ntenan(e (y(les
U
16 - perfor ed (y(les
N (y(le
Off
1 240
Off on
20 100
= start
Off
1 240
0 100
100 10e4
0 10e4
Courtesy light in cycle
Disabled
Courtesy light setting
from 1s to 4min.
When setting this function
the pedestrian input will be
activated to work on the
auxiliary board SEM
(traffic light management).
Setting from 20 to 100
Pause in pedestrian
opening same as in
total opening
Disabled
Setting from 1s to 4 min.
Acceleration ramp
Setting from 100 to
100000
Reports the executed
cycles. Keep pressed OK
to reset the cycles
N (y(le
Off
30
= start
* 70
10e4
0
67411370
REV 03 - 11/2014
23
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
English
USER 1 - 24V DG R1
For garage door
MENU SP
U
17 - t er
18 - edge
19 - PXOTO1
SET
off
ON PXOTO2
ON PEDESTR AN ENTRY
U
Nor al
8x2
(LOS NG
OPEN NG AND (LOS NG
stop
Stop AND (LOSE
(LOSE
PAUSE RELOAD
u
Delay pause ti e
Description
Disabled
Timer function active
on photocell 2
Timer function active on
pedestrian input
Normal N.C. contact
Edge is active and
protected by a 8k2 resistor
Photocell active in closing
Photocell active in opening
and closing
Photocell active before
opening
The photocell stops in closing
and closes when released
The photocell gives a
command to close during
opening, pause and
closing
The photocell charging the
pausing time
If the photocell is occupied
during opening, pause or
closing, the gate reopens
completely and closes
without observing the
pause time.
Default
off
U
Nor al
(LOS NG
Set Value
20 - PXOTO2
(LOS NG
OPEN NG AND (LOS NG
stop
Stop AND (LOSE
(LOSE
PAUSE RELOAD
u
Delay pause ti e
Photocell active in closing
Photocell active in opening
and closing
Photocell active before
opening
The photocell stops in closing
and closes when released
The photocell gives a
command to close during
opening, pause and
closing
The photocell charging the
pausing time
If the photocell is occupied
during opening, pause or
closing, the gate reopens
completely and closes
without observing the
pause time.
OPEN NG
24
67411370
REV 03 - 11/2014
Loading...
+ 16 hidden pages
You need points to download manuals.