The information in this section of the manual are only for technicians or for qualified or authorized installers.
GENERAL CHARACTERISTICS
The USER 1 24V control unit has been designed to manage one low voltage motor with or without electronic limit switches.
It is of very small dimensions and besides the possibility to adjust motor speed, amperemetric anti squeezing sensitivity, leaf
delay in closing, pausing time, it is also possible to manage a display, through which it is possible to control a lot of management
functions and the maintenance of the control unit. The most important change however concerns the presence of a BUS
connector with two wires, through which it is possible to connect accessories as photocells, flashing lamp, key switch and so
on,... connecting only two cables with the control unit. The self- learning of working time can be done automatically.
TECHNICAL SPECIFICATIONS
Control unit power supply
Absorption in stand by
Max. motor charge
Max. accessories charge
Max. Flash light charge
Environment temperature
Protection fuse (24V accessories)
Function logic
Opening/closing time
Time of pause
Thrust
Slow down
Input on connecting terminal
Output on connecting terminal
Board dimensions
Specifications of optional batteries
Specifications of external enclosure
24 V
90 mA
90 W x 2
24V 250mA
24V 15W max.
-20°C +50°C
F1 (2A)
Automatic/Step by Step 1/S. By Step 2/Sec./Dead man
In selflearning in programming phase
Adjustable
Adjustable Opening and Closing
Adjustable
Battery power supply / Total opening / Pedestrian
opening adjustable / Edge/ Stop / Limit switch
opening and closing / Encoder/ BUS accessories
Power supply accessories 24V / Motors 24V /
Flashing lamp 24V / BUS
156 x 100 mm
24V Pb 2Ah min.
305 x 225 x 125 mm - Ip55
Special accessories
67411070REV 01 - 12/2010
Battery charger card (cod.23101105), Relay card
for courtesy light or bolt lock (cod.23101106),
Programmer JOLLY (cod.23105276), Programmer
OPEN (cod.23105290), Photocell SUNSET BUS
(cod.23102075)
21
®
USER 1 - 24V
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
English
START - STOP - PEDESTRIAN START - ANTENNA -
2
PHOTOCELL
Photocell 1 Connection
When the ray of the photocell is crossed, and the automation is in phase of closing it reverses its
movement.
Note: If the photocell is not connected, put a jumper between the clamps 1 and 2 of (M10).
+ = 24V - = 0V C = Connection Com = Common
The photocell is also usable in connection with BUS photocells.
M
JOLLY OPTIONS
FOTOCLOSE activation: If activated when the photocell is crossed during the pause, the gate
interrupts the pause and immediately closes again.
TIMER activation: If the entry is activated it turns into a N.O. entry with TIMER function (see TIMER).
FOTOOPEN activation: If activated the photocell blocks the movement as long as it’s busy, when released it opens.
FOT PARK activation: in opening it is not active; when during the pause ”closing with photo” and “automatic
closing” are activated it commands the closing when released, otherwise it’s not active; in closing it stops the
movement as long as it is busy, when released the closing continues.
FOTO STOP activation: When activated before the opening the photocell blocks the automation as long as it
is busy, during the opening it will be ignored. In closing the intervention of the photocell causes the reopening.
Activation PHOTO CLOSE IMMEDIATELY: The photocell stops the gate as long as it is occupied in both
opening and closing, when released it gives a closing command.
24Vaux max 200 mA
M2
TX
RX
JOLLY OPTION
+ 24V
1 2 1 2
M10
-
.
C
.
+
-
N
+
-
Com
1
1
2
2
Through the Jolly programmer it is
possible to chose when having
tension on the 24Vaux output. The
options are: always, only during
opening, only during cycle, only
before opening or only during pause.
PEDESTRIAN START (N.O.)
M7
To obtain a partial opening connect the key-button wires as in the figure. It is possible to connect other
command devices (push button board, radio receiver, keypad).
-
2
2
1
1
N.O.
Note1: The contact for partial opening is a N.O. Contact (Normally open)
Nota2: In manual logic it is necessary to keep pressed the Start Ped. To re-close the automation.
JOLLY OPTIONS
Activation TIMER: this entry can be transformed into TIMER (See TIMER)
Pedestrian opening space : Linearly adjustable from 30% to 100%.
M7
M6
5M
ANTENNA
Connect the antenna
as in the figure.
M5
GND
2
2
1
1
M9
1
M0
22
M9
M6
JOLLY OPTION
TIMER
67411070
STOP (N.C.)
The pressure on this button immediately stops the motor in any condition/position. A start command
2
2
1
1
-
N.C.
is needed to re-start the movement.
After a stop the motor always re-starts in closing.
Notice: If the stop button is not used it is not necessery to close the N.C. contact between the clamps
1 and 2 of M9 as the absence of the stop is revealed during the selflearning phase of the times.
START (N.O.)
An impulse given to this contact opens and closes the automation depending onthe selected logic It
-
2
2
1
1
N.O.
can be given by a key switch, a keypad, etc. To connect the other devices refer to the related
instructions leaflets. (ie. loop detectors and proximity switches)
Note1: In DEAD MAN logic it is necessary to keep pressed the Start for the opening of the
automation.
Can be activated through the Jolly programmer or modifying either the PHOTO entry or the PEDESTRIAN entry.
In both cases it’s a N.O. contact which provoques the opening of the automation keeping it open until it is
activated. When it’s released, the gate attends the set pausing time and executes the reclosing.
Note2: When activated on the pedestrian entry, the pedestrian will be disabled also on the radio transmitter.
Note3: In case of intervention of a security device during the timer (Stop, Ammeter, Edge), to restore the
movement it will be necessary to give a start impulse.
Note4: In case of no power supply with open gate and active Timer the control unit will restore its use, otherwise
if during restore of the power supply the TIMER is not activated it will be necessary to give a start impulse for
the reclosing.
REV 01 - 12/2010
®
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
ENCODER - LIMIT SWITCH
Encoder / Ammeter sensor
The encoder is a device that allows to reveal possible obstacles during the opening and the closing of
the gate. When this device intervenes in opening it causes the inversion of the movement for around
a second, if it intervenes in closing it causes the total reopening.
Note 1: Such function is active through an ammeter sensor on the control board. It is not
necessary to mount any external devices for the respect of legislation.
Note2: The ammeter sensitivity is adjustable both in opening and in closing through the
JOLLY terminal. On the control unit the torque can be adjusted in 4 steps: low, middle,
middle high, high and will be the same in opening and closing. With high torque the gate
reverses after 5 seconds.
Attention: after each intervention of the ammeter sensor it is necessary to give a start impulse
to restore the movement.
JOLLY functions: With the JOLLY programmer the torque parameters can be adjusted linearly
from 10% to 100% on each single motor. Furthermore, they are differentiable between opening and
closing.
Limit switch
For the functioning the presence of both limit
switches in closing and in opening is necessary.
For the right functioning of the limit switch, the movement direction of the motor and the
respective busy limit switches must correspond. Through DIP3 it is possible to
exchange contemporarily the direction of the motor and of the limit switches.
Note: if during programming phase the motor and limit switch times should not
be in phase between them, the gate will start in closing, it stops and will not
complete the selflearning of the times, at this point it will be necessary to
switch off the tension and to invert the cables of the motor and to eventually
exchange the motor direction on DIP 3. The first movement in selflearning must
always be executed in closing.
Com = Common
C = Contact
USER 1 - 24V
M4
Limit
Switch
M8
JOLLY functions:
1) With the Jolly programmer such function is tied up to the presence of at least
one limit switch and it’s possible to activate the function anti-intrusion. When the
limit switch is free it forces the motor to re-close.
2) With the Jolly programmer it is possible to exchange the motor and the limit
switch without setting DIP3 of the control unit.
SECURITY EDGE AND WARNING LAMP
It is possible to connect an active safety edge on the
terminal M8. If this device is pressed it opens the
contact causing a partial inversion of the movement
1
2
both in opening and in closing. If not used bridge
the contacts 1 and 2 of M8. Note: contact N.C.
M8
Costa di sicurezza
Flashing Lamp 24V 15W (Warning lamp )
The warning lamp advises that the automatic gate is moving with 1 flash /second in opening and 2
flashes / second in closing. During pause it remains fixed on.
Connect the cables of the warning lamp as shown in the figure. The pre-flashing function can be
activated with the Jolly terminal or with Led 4 of the menu through the SET and MENU buttons.
Limit
Switch
JOLLY FUNCTIONS:
It is possible to activate the balanced edge 8K2, in this
case the edge contact will be controled by a specific
value of resistance revealing the eventuel unintentional
short circuit of the device. In case of an unbalance of the
device the corresponding led of the terminal board M8
will flash quickly.
M4
2
12 1
67411070
JOLLY functions:
It is possible to activate a pre-flashing of 3 seconds before activating the automation, on setting preflashing on ON, through the Jolly programmer. Furthermore from the flashing lamp it is possible to verify
some alarm signals. See alarms indications.
Through the Jolly programmer it is possible to set this exit with fixed flashing also when the gate is not
moving or it is possible to change this exit into control lamp. In such case all the indications of alarm
remain on the warning lamp as long as they are active.
REV 01 - 12/2010