CENTRALE DI COMANDO PER CANCELLI SCORREVOLI, SINGOLA ANTA BATTENTE, BARRIERE E PORTE DA GARAGE
CONTROL UNIT FOR SLIDING GATES, SWING SINGLE LEAF, BARRIERS AND GARAGE DOORS
ARMOIRE DE COMMANDE POUR PORTAILS COULISSANTS, UN VANTAIL BATTANT, BARRIERES ET PORTES DE GARAGE
CENTRAL ELECTRÓNICA PARA CANCELAS CORREDIZAS, HOJA INDIVIDUAL ABATIBLE, BARRERAS Y PUERTAS BASCULANTES
Español
(Cod. 23001245)
67411695
SEA S.p.A.
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. +39 0861 588341 r.a. Fax +39 0861 588344
www.seateam.com
seacom@seateam.com
Rev.03 - 11/2015
COMPONENTS
TECHNICAL SPECIFICATIONS
Control unit power supply: 230 Vac 50/60 Hz - 115Vac 50/60 Hz
Absorption in stand by: 30 mA
Environment temperature : -20°C +50°C
Specifications of external enclosure: 183 X 238 X 120 - Ip55
English
RECEIVER RX
155 mm
CNS
F1
TR1
CN5
MEMO
CN3
R1
CN2
T1
R2
F2
JOLLY
CNA
CNS
CN1 = Input/output connectors
CN2 = Motor and courtesy light connector
CN3 = Power connector
CN5 = Encoder connector
CN6 =
CN7=
OK = Programming button
DOWN = Programming button
UP = Programming button
T1 = Motor piloting Triac
R1 = Relay motor command / Courtesy light
R2 = Relay motor exchange
F1 = 6.3AT fuse on 230V - 10AT on 115V
F2 = Accessories 1A fuse
TR1 = Power transformer
MEMO = Remote controls memory (optional)
DS = Programming display
24
CONNECTIONS
English
RADIO MODULE RF FIX
(CNS)
RF FIX
Receiver
connector
(Available from
hardware
revision R1)
CNA
RADIO MODULE RF
(SERIES UNI)
CN2
17 16
LIGHT MOP MNMCL
Flash
Motor 1 opening
2
1
ANT COM
START
15
Motor 1 Neutral
M1
34
PEDST
14
CN3
LN
Line
Motor 1 closing
56
STOP COM PH1 OPT1
Not connected
CN1
78
Limit switch Closing 1 (Yellow)
Limit switch Opening 1 (Green)
Neutral
Limit switch Closing 1 (Yellow)
Limit switch Opening 1 (Green)
9
10
11
EDGE
OPT2 COM
24V(FL)
24V (Red)
Common (White)
12
13
FL(-)
CN6
LIMIT SWITCH
1
CN7
Flash (-)
24V (FL) (200 mA)
Accessories+flash led
Contacts N.C.
24VDC
OPT2 (-)
OPT1 (Not connected)
Start
Antenna
Common
Stop
Common
START Ped.
Loop 1 - Photocell 1
Edge 1
Common
NO JUMPERS NEEDED ON N.C. CONTACTS
WARNING: Automatic detection of not used N.C. inputs (Photocell, Limit switch and Edge).
To reactivate an NC contact you follow this procedure:
SEA
MENU
Go to press the button for 5 seconds then you enter
the INPUT CHECK MENU, where you can check the operating status of all inputs (pg 9).
SET
1-LANGUAGE
OK
No need to repeat self programming after reactivation of N.C. contacts.
THE HEREIN REPORTED FUNCTIONS ARE AVAILABLE STARTING FROM
REVISION 15.
25
A) 24V DC 12
English
SAFETY DEVICES
CONNECTIONS
PHOTOCELL 1 (LOOP 1)
+ = 24V (FL) COM = 0V PH1 = Photocell contact 1
Default setting: PHOTO 1 = “Closing”.
For the options of the photocell (menu 97) see page 17.
AUTOTEST Function: Check that the photocells are working properly
before each movement. If the test fails it’s indicated on the display.
To activate AUTOTEST:
1) Connect the TX photocell power on 24V (FL) input 12 and 10.
2) Go on 94-24V AUX menu and activate this mode.
Nota: Auto-test is possible only when the transmitter of the photocell is
powered 24V (FL) and OPT2, adjusting the autotest function in the
94-24V AUX menu.
RX1
6
7
11
12
CN1
1 2 3 4 5 6 7 8
C
9 10 11 12 13
- +
TX1
11
12
N.B: If you want the Autotest, just connect the positive of the devices to be tested on the input 12
or the negative on the input 10 (OPT2) .
B) 24V DC AUX PROGRAMMABLESU USCITA OPT2 10
The options of 94-24V AUX menu are:
On the 24VAUX you can select when and how to
operate the connected auxiliary accessory. See
menu 94-24V AUX.
Max load 200 mA
• Always
• In cycle
• Opening
• Closing
• In pause
• Autotest
• In cycle and fototest
• Positive brake management
• Negative brake management
(See special menu pg. 17)
SEA
MENU
94-24V AUX
SET
26
PARTIAL OPENING, STOP, START
CONNECTIONS
English
PARTIAL OPENING (N.O.) 4
• Function 1 (STANDARD): partial opening space adjustble from 20 to 100 (90-
PARTIAL OPENING menu).
• Function 2 (TIMER): by holding partial opening the gate opens and then stay
opened. Al rilascio the gate repeat the pause selected time and start closing.
In case a safety is activated the timer will automatically reset after 6 sec.
• Function 3 (2 BUTTONS): in 2 buttons logic press the partial opening to close the
gate.
• Function 4 (DEADMAN): in deadman logic the partial opening executes the reclosing if you keep it pressed.
STOP (N.C.) 5
When pressing this button the motor immediately stops in any
condition/position.
To re-start the movement give a start command.
After a stop the motor always re-starts in closing.
START (N.O.) 3
• Function 1 (STANDARD): a
contact opens and closes the automation depending on the
Selected logic.
• Function 2 (TIMER): h
and then close.
In case of activation of a safety device the timer will automatically reset after 6 seconds.
• Function 3 (2 BUTTONS):
• Function 4 (DEADMAN):
n impulse given to this
olding START starts the TIMER function, releasing the start, the operator repeats the pause
To connect the other devices refer to the related instructions leaflets (ie. loop detectors).
in 2 buttons logic this button performs the opening.
in deadman logic keep pressed the Start for the opening of the automation.
PARTIAL
OPENING
ANTENA
START
4
6
STOP
CN1
1 2 3 4 5 6 7 8 9
-
3
6
5
6
C
10 11 12 13
SAFETY EDGE AND FLASHING LAMP
CONNECTIONS
SAFETY EDGE 9 and 11
SAFETY EDGE
Safety edges (EDGE) can be connected between the
contacts 9 and 11 of CN1.
Pressing EDGE, the contact opens, causing a partial
reversing of the gate in closing and opening.
Note1: If the edge contact is not used it must be
briged The EDGE input can be set: only in closing,
.
only in opening or in both directions.
24V FLASHING LIGHT 4W MAX 12 and 13
The warning lamp can be connected between the terminals 24V(FL) and FL(-) of CN1
It blinks once per second during opening and twice per second during closing, while it remains lit during pause.
Throught the warning lamp it is also possible to identify alarm signals comming from the STOP, PHOTOCELL 1
and EDGE devices.
Sul display a bordo è possibile attivare la funzione prelampeggio e/o modificare il lampeggio fisso, la lampada spia
o il Buzzer.
The pre-flashing can be set from 0 to 5 s. or it is possible to have it only before closing.
1 2 3 4 5 6 7 8 9
Safety edge
in closing
CN1
10 11 12 13
+
9
11
-C
13
12
27
ENCODER
English
CONNECTIONS
ENCODER (Connector CN5)
The Encoder can be used both on electromechanical and hydraulic operators.
The Encoder allows the detection of the gate position and its reversing in case of obstacles. To use the ENCODER it is
necessary to enable it inside the special 32-ENCODER menu. The sensitivity on the obstacle is adjustable from 0 - 99%. The
higher the percentage is the more it will be difficult to detect the obstacle.
NOTE: If the Encoder is activated it is possible to visualize in the special menu the total memorized impulses and the partial
impulses executed by the motor.
ATTENTION: The first operation, after power failure will be for searching the mechanical stops at the
end of the run and the gate could not perform the slowdown.
COURTESY LIGHT, MOTOR, CAPACITY
AND POWER SUPPLY CONNECTIONS
COURTESY
LIGHT
CN2
CN3
Timing
from 0 to 4 min
(230V~ 50W Max -
115V~ 50W Max)
always On
during cycle
Capacitor
Motor
Motor connection
M = Opening /Closing
Com = COMMON
15
17
16
14
Example
17 16 15 14
Neutral
Opening
Closing
M
16
15
14
N L
Neutral
Line
POWER SUPPLY INPUT
NOTE: For power supply connection follow the rules in force
28
THREE-PHASE MODULE CONNECTION
Power supply connector
for control unit (230V)
23001245 (SLIDE DG R2F)
English
Motor wiring connector for control unit (230V)
23001245 (SLIDE DG R2F)
N
L
15
16
CN1CN1
17 16 15 14
14
Three-phase
Motor (380V~)
UU VV WW
NN NN FF COM.COM.
OP.OP.
CL.CL.
K1K1
CN2CN2
Grounding
FST1
NN RR SS TT
Three-phase
power supply
380V~
R (2T1)R (2T1)
S (4T2)S (4T2)
T (6T3)T (6T3)
T1T1
K2K2
THREE-PHASE
MODULE
K1-K2 = Terminals 230V~ 16A
T1= Thermal switch (limit 3,7A)
CN1= Power supply connector for elect. control unit (220V)
CN2= Power supply connector for three-phase motor (380V)
FST1 = Grounding faston
Important note: select in the settings of the motor menu the configuration “Trifase-Bull” , ref.. Pag.14
29
CONNECTIONS
SAFETY LOOP
English
Safety loop
Connecting scheme of
loop detector 1 reader
7 = Contact photocell 1 (N.C.)
6 = Common
Free exit loop
CN1
1 2 3 4 5 6 7 8 9
-
C
C2 C2C1
10 11 12 13
11
DRAWING SHOWS HOW TO
EVENTUALLY CONNECT THE
MAGNETIC LOOP
C1 = CONTACT OPEN
C2 = CONTACT CLOSED
12 = 24 V
11 = 0 V
12
Loop1
Safety
loop
7
6
Free exit
loop
Loop2
3
6
Connecting scheme of loop
detector reader
3 = Contact start (N.O.)
6 = Common
CONNECTING SCHEME OF THREE READERS OF MAGNETIC LOOP DETECTORS:
(TWO OF THEM USED AS SECURITY DEVICE AND ONE AS EXIT)
SAFETY LOOP SYSTEM
S
AF Y
ET
LOO
SA TY
FE
PLOO
P
EXIT LOOP SYSTEM
Loop3
F
LOO
SAF YET
LO
OP
SAY
FET
PLOO
E ITRE
EX
P
30
PRE SET PARAMETERS AND NO/NC CONTACTS
English
1
- When N.C. (Photo, Stop, Limit switch and Edge)
DISPLAY INPUTS STATUS
Start
Limit
Switch
opening
motor 1
Limit
Switch
closing
motor 1
Photocell 1
Pratial
opening
MENU
SEA
- - -
- -
- - -
OPT1
(undefined)
SEA
MENU
MENU
-
SEA
SET
SET
Stop
SET
Edge
N.C contacts
When not engaged or not wired
When cross photo or input is engaged
SEA
MENU
- When N.O. (Start, Partial opening)
MENU
Power OFF
-
SEA
SET
When input is engaged
SET
When input is not engaged
N.O. contacts
2
F
OF
Power ON
Keep pressed the two buttons and . At the same time put to start initialisation
3
UPDOWN
of the board until you see INIT on the display.
SEA
MENU
4
INIT
SET
All parameters will return to the DEFAULT configuration, see "Default" column in the tables of the menus and
all inputs will display their real state.
N
O
SEA
MENU
4
SET
All contacts N.C. are automatically turned off if not used (no segment on the display).
If the contacts are connected, on the display they will appear in ON (lit segment).
31
English
INPUTS CHECK MENU
SEA
MENU
SET
Moving in the menu pressing the button for 5 seconds, you enter the CHECK
MENU, where you can check the operating status of all inputs.
MENU
START
STOP
PARTIAL OPENING START
EDGE
PHOTO1
LIMIT SWITCH
OPENING
LIMIT SWITCH
CLOSING
1-LANGUAGE
OK
MENU FUNCTION TABLE CHECK SLIDE DG R2F INPUTS
To access the Menu for input check keep pressed OK for about 5 seconds.
Description
OK
OK
OK
Enabled
Blocked
Enabled
Blocked
Enabled
Blocked
Description
Start test
Partial opening
start test
Safety edge
test
Opening
limit switch
test
Closing
limit switch
test
The contact must be a N.O. Contact . When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.O. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
IThe contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works. If SET is always on, make
sure that the contact is a N.C. contact or that the related limit switch is not occupied.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works. If SET is always on, make
sure that the contact is a N.C. Contact or that the related limit switch is not occupied.
END
Exit menu
Note: If the Stop and Photocell contacts are not bridged in self-learning, they will be deactivated and
can be reactivated through this menu, without repeating times self-learning.