SEA Slide DG User Manual

®
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
Italiano
English
Français
SLIDE DG R2F
CENTRALE DI COMANDO PER CANCELLI SCORREVOLI, SINGOLA ANTA BATTENTE, BARRIERE E PORTE DA GARAGE
CONTROL UNIT FOR SLIDING GATES, SWING SINGLE LEAF, BARRIERS AND GARAGE DOORS
ARMOIRE DE COMMANDE POUR PORTAILS COULISSANTS, UN VANTAIL BATTANT, BARRIERES ET PORTES DE GARAGE
CENTRAL ELECTRÓNICA PARA CANCELAS CORREDIZAS, HOJA INDIVIDUAL ABATIBLE, BARRERAS Y PUERTAS BASCULANTES
Español
(Cod. 23001245)
67411695
SEA S.p.A.
Zona industriale 64020 S.ATTO Teramo - (ITALY)
www.seateam.com
seacom@seateam.com
Rev.03 - 11/2015
COMPONENTS
TECHNICAL SPECIFICATIONS
Control unit power supply: 230 Vac 50/60 Hz - 115Vac 50/60 Hz Absorption in stand by: 30 mA Environment temperature : -20°C +50°C Specifications of external enclosure: 183 X 238 X 120 - Ip55
English
RECEIVER RX
155 mm
CNS
F1
TR1
CN5
MEMO
CN3
R1
CN2
T1
R2
F2
JOLLY
CNA
CNS
CN1 = Input/output connectors CN2 = Motor and courtesy light connector CN3 = Power connector CN5 = Encoder connector CN6 = CN7=
Pre-wired limit switch connector
Limit switch connector not pre-wired
CNA = UNI Receiver connector CNS = RF FIX Receiver connector CNP = Porgramming connector JOLLY = Jolly and Jolly 2 connector
DS
CNP
JOLLY-JOLLY2
CN6
UP DOWN OK
CN7
CN1
85 mm
OK = Programming button DOWN = Programming button UP = Programming button T1 = Motor piloting Triac R1 = Relay motor command / Courtesy light R2 = Relay motor exchange F1 = 6.3AT fuse on 230V - 10AT on 115V F2 = Accessories 1A fuse TR1 = Power transformer MEMO = Remote controls memory (optional)
DS = Programming display
24
CONNECTIONS
English
RADIO MODULE RF FIX
(CNS)
RF FIX
Receiver
connector
(Available from
hardware
revision R1)
CNA
RADIO MODULE RF
(SERIES UNI)
CN2
17 16
LIGHT MOP MN MCL
Flash
Motor 1 opening
2
1
ANT COM
START
15
Motor 1 Neutral
M1
3 4
PEDST
14
CN3
L N
Line
Motor 1 closing
5 6
STOP COM PH1 OPT1
Not connected
CN1
7 8
Limit switch Closing 1 (Yellow)
Limit switch Opening 1 (Green)
Neutral
Limit switch Closing 1 (Yellow)
Limit switch Opening 1 (Green)
9
10
11
EDGE
OPT2 COM
24V(FL)
24V (Red)
Common (White)
12
13
FL(-)
CN6
LIMIT SWITCH
1
CN7
Flash (-)
24V (FL) (200 mA)
Accessories+flash led
Contacts N.C.
24VDC
OPT2 (-)
OPT1 (Not connected)
Start
Antenna
Common
Stop
Common
START Ped.
Loop 1 - Photocell 1
Edge 1
Common
NO JUMPERS NEEDED ON N.C. CONTACTS
WARNING: Automatic detection of not used N.C. inputs (Photocell, Limit switch and Edge).
To reactivate an NC contact you follow this procedure:
SEA
MENU
Go to press the button for 5 seconds then you enter
the INPUT CHECK MENU, where you can check the operating status of all inputs (pg 9).
SET
1-LANGUAGE
OK
No need to repeat self programming after reactivation of N.C. contacts.
THE HEREIN REPORTED FUNCTIONS ARE AVAILABLE STARTING FROM
REVISION 15.
25
A) 24V DC 12
English
SAFETY DEVICES
CONNECTIONS
PHOTOCELL 1 (LOOP 1)
+ = 24V (FL) COM = 0V PH1 = Photocell contact 1 Default setting: PHOTO 1 = “Closing”. For the options of the photocell (menu 97) see page 17.
AUTOTEST Function: Check that the photocells are working properly before each movement. If the test fails it’s indicated on the display. To activate AUTOTEST:
1) Connect the TX photocell power on 24V (FL) input 12 and 10.
2) Go on 94-24V AUX menu and activate this mode.
Nota: Auto-test is possible only when the transmitter of the photocell is
powered 24V (FL) and OPT2, adjusting the autotest function in the 94-24V AUX menu.
RX1
6
7
11
12
CN1
1 2 3 4 5 6 7 8
C
9 10 11 12 13
- +
TX1
11
12
N.B: If you want the Autotest, just connect the positive of the devices to be tested on the input 12 or the negative on the input 10 (OPT2) .
B) 24V DC AUX PROGRAMMABLE SU USCITA OPT2 10
The options of 94-24V AUX menu are:
On the 24VAUX you can select when and how to operate the connected auxiliary accessory. See menu 94-24V AUX.
Max load 200 mA
• Always
• In cycle
• Opening
• Closing
• In pause
• Autotest
• In cycle and fototest
• Positive brake management
• Negative brake management
(See special menu pg. 17)
SEA
MENU
94-24V AUX
SET
26
PARTIAL OPENING, STOP, START
CONNECTIONS
English
PARTIAL OPENING (N.O.) 4
• Function 1 (STANDARD): partial opening space adjustble from 20 to 100 (90-
PARTIAL OPENING menu).
• Function 2 (TIMER): by holding partial opening the gate opens and then stay opened. Al rilascio the gate repeat the pause selected time and start closing. In case a safety is activated the timer will automatically reset after 6 sec.
• Function 3 (2 BUTTONS): in 2 buttons logic press the partial opening to close the gate.
• Function 4 (DEADMAN): in deadman logic the partial opening executes the re­closing if you keep it pressed.
STOP (N.C.) 5
When pressing this button the motor immediately stops in any condition/position. To re-start the movement give a start command. After a stop the motor always re-starts in closing.
START (N.O.) 3
• Function 1 (STANDARD): a
contact opens and closes the automation depending on the Selected logic.
• Function 2 (TIMER): h and then close. In case of activation of a safety device the timer will automatically reset after 6 seconds.
• Function 3 (2 BUTTONS):
• Function 4 (DEADMAN):
n impulse given to this
olding START starts the TIMER function, releasing the start, the operator repeats the pause
To connect the other devices refer to the related instructions leaflets (ie. loop detectors).
in 2 buttons logic this button performs the opening.
in deadman logic keep pressed the Start for the opening of the automation.
PARTIAL
OPENING
ANTENA
START
4
6
STOP
CN1
1 2 3 4 5 6 7 8 9
-
3 6
5 6
C
10 11 12 13
SAFETY EDGE AND FLASHING LAMP
CONNECTIONS
SAFETY EDGE 9 and 11
SAFETY EDGE
Safety edges (EDGE) can be connected between the contacts 9 and 11 of CN1. Pressing EDGE, the contact opens, causing a partial reversing of the gate in closing and opening.
Note1: If the edge contact is not used it must be briged The EDGE input can be set: only in closing,
.
only in opening or in both directions.
24V FLASHING LIGHT 4W MAX 12 and 13
The warning lamp can be connected between the terminals 24V(FL) and FL(-) of CN1
It blinks once per second during opening and twice per second during closing, while it remains lit during pause. Throught the warning lamp it is also possible to identify alarm signals comming from the STOP, PHOTOCELL 1 and EDGE devices. Sul display a bordo è possibile attivare la funzione prelampeggio e/o modificare il lampeggio fisso, la lampada spia o il Buzzer.
The pre-flashing can be set from 0 to 5 s. or it is possible to have it only before closing.
1 2 3 4 5 6 7 8 9
Safety edge
in closing
CN1
10 11 12 13
+
9
11
-C
13
12
27
ENCODER
English
CONNECTIONS
ENCODER (Connector CN5)
The Encoder can be used both on electromechanical and hydraulic operators. The Encoder allows the detection of the gate position and its reversing in case of obstacles. To use the ENCODER it is necessary to enable it inside the special 32-ENCODER menu. The sensitivity on the obstacle is adjustable from 0 - 99%. The higher the percentage is the more it will be difficult to detect the obstacle. NOTE: If the Encoder is activated it is possible to visualize in the special menu the total memorized impulses and the partial impulses executed by the motor.
ATTENTION: The first operation, after power failure will be for searching the mechanical stops at the end of the run and the gate could not perform the slowdown.
COURTESY LIGHT, MOTOR, CAPACITY
AND POWER SUPPLY CONNECTIONS
COURTESY
LIGHT
CN2
CN3
Timing
from 0 to 4 min
(230V~ 50W Max -
115V~ 50W Max)
always On
during cycle
Capacitor
Motor
Motor connection
M = Opening /Closing
Com = COMMON
15
17
16
14
Example
17 16 15 14
Neutral
Opening
Closing
M
16
15
14
N L
Neutral
Line
POWER SUPPLY INPUT
NOTE: For power supply connection follow the rules in force
28
THREE-PHASE MODULE CONNECTION
Power supply connector
for control unit (230V)
23001245 (SLIDE DG R2F)
English
Motor wiring connector for control unit (230V)
23001245 (SLIDE DG R2F)
N
L
15
16
CN1CN1
17 16 15 14
14
Three-phase
Motor (380V~)
UU VV WW
NN NN FF COM.COM.
OP.OP.
CL.CL.
K1K1
CN2CN2
Grounding
FST1
NN RR SS TT
Three-phase
power supply
380V~
R (2T1)R (2T1)
S (4T2)S (4T2)
T (6T3)T (6T3)
T1T1
K2K2
THREE-PHASE
MODULE
K1-K2 = Terminals 230V~ 16A T1 = Thermal switch (limit 3,7A) CN1 = Power supply connector for elect. control unit (220V) CN2 = Power supply connector for three-phase motor (380V) FST1 = Grounding faston
Important note: select in the settings of the motor menu the configuration “Trifase-Bull” , ref.. Pag.14
29
CONNECTIONS
SAFETY LOOP
English
Safety loop
Connecting scheme of loop detector 1 reader
7 = Contact photocell 1 (N.C.) 6 = Common
Free exit loop
CN1
1 2 3 4 5 6 7 8 9
-
C
C2 C2C1
10 11 12 13
11
DRAWING SHOWS HOW TO EVENTUALLY CONNECT THE MAGNETIC LOOP
C1 = CONTACT OPEN C2 = CONTACT CLOSED 12 = 24 V 11 = 0 V
12
Loop1
Safety
loop
7
6
Free exit
loop
Loop2
3
6
Connecting scheme of loop detector reader
3 = Contact start (N.O.) 6 = Common
CONNECTING SCHEME OF THREE READERS OF MAGNETIC LOOP DETECTORS: (TWO OF THEM USED AS SECURITY DEVICE AND ONE AS EXIT)
SAFETY LOOP SYSTEM
S
AF Y
ET
LOO
SA TY
FE
PLOO
P
EXIT LOOP SYSTEM
Loop3
F
LOO
SAF YET
LO
OP
SA Y
FET
PLOO
E ITRE
EX
P
30
PRE SET PARAMETERS AND NO/NC CONTACTS
English
1
- When N.C. (Photo, Stop, Limit switch and Edge)
DISPLAY INPUTS STATUS
Start
Limit Switch opening motor 1
Limit Switch closing motor 1
Photocell 1
Pratial
opening
MENU
SEA
- - -
- -
- - -
OPT1
(undefined)
SEA
MENU
MENU
-
SEA
SET
SET
Stop
SET
Edge
N.C contacts
When not engaged or not wired
When cross photo or input is engaged
SEA
MENU
- When N.O. (Start, Partial opening)
MENU
Power OFF
-
SEA
SET
When input is engaged
SET
When input is not engaged
N.O. contacts
2
F
OF
Power ON
Keep pressed the two buttons and . At the same time put to start initialisation
3
UP DOWN
of the board until you see INIT on the display.
SEA
MENU
4
INIT
SET
All parameters will return to the DEFAULT configuration, see "Default" column in the tables of the menus and all inputs will display their real state.
N
O
SEA
MENU
4
SET
All contacts N.C. are automatically turned off if not used (no segment on the display). If the contacts are connected, on the display they will appear in ON (lit segment).
31
English
INPUTS CHECK MENU
SEA
MENU
SET
Moving in the menu pressing the button for 5 seconds, you enter the CHECK
MENU, where you can check the operating status of all inputs.
MENU
START
STOP
PARTIAL OPENING START
EDGE
PHOTO1
LIMIT SWITCH OPENING
LIMIT SWITCH CLOSING
1-LANGUAGE
OK
MENU FUNCTION TABLE CHECK SLIDE DG R2F INPUTS
To access the Menu for input check keep pressed OK for about 5 seconds.
Description
OK
OK
OK
Enabled
Blocked
Enabled
Blocked
Enabled
Blocked
Description
Start test
Partial opening
start test
Safety edge
test
Opening
limit switch
test
Closing
limit switch
test
The contact must be a N.O. Contact . When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.O. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
IThe contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works. If SET is always on, make
sure that the contact is a N.C. contact or that the related limit switch is not occupied.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works. If SET is always on, make
sure that the contact is a N.C. Contact or that the related limit switch is not occupied.
END
Exit menu
Note: If the Stop and Photocell contacts are not bridged in self-learning, they will be deactivated and can be reactivated through this menu, without repeating times self-learning.
32
Loading...