Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
Italiano
English
Français
SLIDE AN
CENTRALE DI COMANDO PER CANCELLI SCORREVOLI, SINGOLA ANTA BATTENTE, BARRIERE E PORTE DA GARAGE
CONTROL UNIT FOR SLIDING GATES, SWING SINGLE LEAF, BARRIERS AND GARAGE DOORS
ARMOIRE DE COMMANDE POUR PORTAILS COULISSANTS, UN VANTAIL BATTANT, BARRIERES ET PORTES DE GARAGE
CENTRAL ELECTRÓNICA PARA CANCELAS CORREDIZAS, HOJA INDIVIDUAL ABATIBLE, BARRERAS Y PUERTAS BASCULANTES
Español
67411975
SEA S.p.A.
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. +39 0861 588341 r.a. Fax +39 0861 588344
www.seateam.com
seacom@seateam.com
Rev.01 - 04/2016
1
®
Sistemi Elettronici
di Apertura Porte e Cancelli
English
English
COMPONENTS DESCRIPTION
TECHNICAL SPECIFICATIONS
Control unit power supply: 230 Vac 50/60 Hz - 115Vac 50/60 Hz
Absorption in stand by: 30 mA
Environment temperature : -20°C +50°C
Specifications of external enclosure: 183 X 238 X 120 - Ip55
SLIDE AN
RX RECEIVER
144 mm
CNS
CNS
CNA
L1
F1
R2
DS
ON ON
ON ON
P1
TR
4
3
2
1
CN4
TR1 TR2 TR3
CNP
CN3
T1
R1
R3
CN1 = inputs / outputs connector
CN2 = Clean contact connector
CN3 = Motor and light connector
CN4 = Power Connector
CNA = UNI receiver connector
CNS = RF FIX receiver connector
CNP = Programming connector
TR1 = Work time Trimmer
TR2 = Motor torque trimmer
Tr3 = Pause time trimmer
10
CN1
CN2
85 mm
P1 = Transmitter programming button
T1 = Triac motor drive
R1 = Motor control / courtesy light relay
R2 = Motor exchange relay
R3 = 1A Dry contact relay
F1 = 6.3AT fuse on 230V - 10AT on 115V
TR = Power Transformer
DS = Dip switches logics and photocells
L1 = Transmitters programming LED
®
Sistemi Elettronici
di Apertura Porte e Cancelli
English
English
CONNECTIONS
SLIDE AN
CNS
RF FIX RADIO MODULE
RF FIX
receiver
connector
(Available from
hardware revision R1)
CNA
RF RADIO MODULE
(UNI SERIES)
CN3
17 16
LIGHT MOP MN MCL
Light
Motor 1 opening
2
1
ANT COM
3 4
START
14
15
Motor 1 Neutral
M1
PEDST
L
Motor 1 closing
CN1
5 6
STOP COM PH
7 8
CN4
Line
N
Neutral
Not connected
9
24Vac 200mA
CN2
20
21
DRY CONTACT 1A
Active for a second
at every start impulse
11
COM
12
LSO
10
EDGE
13
LSC
N.C. Contacts
24Vac
Antenna
Start
Common
Stop
Common
Ped. START
Coil - Photocell
Edge 1
Common
Common
Limit switch opneing
Limit switch closing
JUMPER NEEDED ON N.C. CONTACTS
ATTENTION: Bridge the N.C. Inputs which are not used, except of the limit switches
(Photocell, STOP and Edge) .
DIP SWITCH ADJUSTMENT
4
Mode4
Photocell function
3
Mode3
DIP
2
1
Mode2
Mode1
Logic choice
DIP
1 / 2
1 / 2
1 / 2
1 / 2
1 / 2
OFF / OFF
ON / OFF
OFF / ON
ON / ON
FONCTION
STEP STEP 1
AUTOMATIC
2 BUTTONS
DEADMAN
DIP
1 / 2
1 / 2
1 / 2
1 / 2
3 / 4
OFF / OFF
ON / OFF
OFF / ON
ON / ON
FONCTION
PHOTOCELL ONLY CLOSING
PHOTOCELL RESETS PAUSE
PHOTOCELL RECHARGES PAUSE
PHOTOCELL OPENING AND CLOSING
11
®
Sistemi Elettronici
di Apertura Porte e Cancelli
English
English
CONNECTIONS
SAFETY DEVICES
A) 24V ac ~ max 200mA 8
SLIDE AN
CN1
PHOTOCELL (COIL)
24Vac (8) COM (-)= 0V (9) PH (C)= Photocell contact (7)
The photocell can be configured as: closure only, opening and closing,
pause recharging and reset pause
Note: Brigde the photocell contact if not used.
6
7
RX1
8
9
TX1
8
9
C
+
9 10 11 12 13
1 2 3 4 5 6 7 8
-
-
PHOTOCELL (COIL) OPTIONS
Closing 1 OFF / 2 OFF
Opening 1 ON / 2 OFF
Pause recharge 1 OFF / 2 ON
Pause reset 1 ON / 2 ON
If the photocell is engaged during closing it inverts the movement
Photocell is active during opening and closing. If the photocell is committed
during opening, the gate stops, when released the gate continues the
opening. In closing the gate stops and when released it goes back to opening.
The photocell recharges the pause time
If the photocell is engaged during opening, pause or closing, the gate opens
completely and it closes again without respecting the pause time.
SAFTY EDGE CONNECTION
SAFETY EDGE 9 and 10
It is possible to connect the safety edge (EDGE)
between contacts 9 and 10 of CN1.
If it’s squeezed, the contact opens causing a partial
inversion of the mouvement.
CN1
1 2 3 4 5 6 7 8 9
10 11 12 13
C
Note 1: Bridge the edge contact if not used
12
Closing
safety edge
9
10
®
Sistemi Elettronici
di Apertura Porte e Cancelli
CONNECTIONS
PARTIAL OPENING, STOP, START
SLIDE AN
PARTIAL OPENING (N.O.) 4
Function 1 (STANDARD): pedestrian opening will be 50% of the set working time
• Function 2 (TIMER): holding the pedestrian start the gate opens and remains open.
When released the gate repeats the selected pause and starts closing. In the case in
which a security is activated, the timer automatically resets after 6 seconds ( f
function active only in automatic logic)
• Function 3 (2 BUTTONS: in "2 buttons" logic press the pedestrian start to close the
gate.
• Function 4 (DEADMAN): in "deadman" logic the pedestrian start will execute the
closing if kept pressed.
ANTENNA
STOP (N.C.) 5
When pressing this button the motor immediately stops in any
condition/position.
To re-start the movement give a start command. After a stop the motor
always re-starts in closing.
Note: Bridge the STOP contact if not used.
START (N.O.) 3
Function 1 (STANDARD): If a pulse is sent to
this input it determines the opening / closing of the
automation depending on the selected logic.
• Function 2 (TIMER): The hold START triggers the TIMER function, when the start is released it the automation
repeats the pause time and then performs the closing. To connect the supplied devices (such as the coil) please
see the specific instructions. In case of intervention of a safety device the timer will automatically reset after 6 s.
• Function 3 (2 BUTTONS): In 2 BUTTONS logic it performs the opening (function only active in automatic logic)
• Function 4 (DEADMAN): In DEADMAN logic START must be pressed for the opening of the automation.
PARTIAL
OPENING
4
6
1 2 3 4 5 6 7 8 9
-
START
3
6
STOP
5
6
CN1
10 11 12 13
C
MECHANICAL LIMIT SWITCHES
CONNECTION
LIMIT SWITCH 11 12 13
If not connected they must not be bridged.
For the limit switch function, limit switches are required in both
opening and closing.
For the correct operation of the limit switch there must be
correspondence between the direction of motor and the respective
engaged limit switch.
Com = Common
C= Contact
MAGNETIC LIMIT SWITCHES
CONNECTION
To enable the control unit to function with magnetic limit switches it must
be turned on by keeping pressed P1 for 5 s. The correct setting will be
indicated by three slow flashes of L1.
4 slow flashes indicate, instead, mechanical limit switch.
!
LIMIT SWITCH 11 12 13
If not connected they must not be bridged.
For the limit switch function, limit switches are required in both
opening and closing.
For the correct operation of the limit switches there must be
correspondence between the direction of motor and the respective
engaged limit switches.
Com = Common
C= Contact
NOTE: WARNING CONTACT NORMALLY OPEN
Llimit switch
opening
Limit switch
closing
Limit switch
opening
Limit switch
closing
CN1
1 2 3 4 5 6 7 8
N.C.
12
N.C.
1
3
9 10 11 12 13
11
1
1
CN1
1 2 3 4 5 6 7 8
N.O.
11
12
N.O.
1
1
3
N C C
9 10 11 12 13
N C C
1
13