Table of contents
Technical characteristics, 10
Electrical connection, 11
Safety measures, 12
Installation, 13
Operation, 14
External exhausting version
Operation with recirculated air
Use of the hood, 15
Lighting, 15
Cleaning, 16
GB
9
Technical characteristics
Metal grease filter
Aspiration area (cm
2
) 1168
GB
Models GFI 681
Dimensions (in mm)
Width (hole on the bottom side of the cabinet) 750 (696)
depth (hole on the bottom side of the cabinet) 490
height (min./max.) 147
Ø of exhausting connection 120
Weight (in kg) 6,3
Absorption (in watts - 220-240 V ~)
Rated absorption 280
Motor absorption 2 x 120
Lighting absorption (Halogen lamp) 2 x 20
10
Electrical connection
! Warning: This appliance must be earthed.
Before installing the hood, it is vital to ensure that the
mains voltage corresponds to the voltage indicated on
the unit’s data plate.
! Only an authorised electrician should connect the
unit to the mains power supply.
! The unit is fitted with an electrical supply chord in
compliance with European standards.
! Attention: if the appliance is permanently connected
to the mains, the plug supplied must be removed and
safely disposed of. The appliance must then be fitted
with a bipolar switch in compliance with current
regulations and have a minimum contact break of
.
3 mm
! The manufacturer will not be held liable for any
problems caused by the user’s failure to observe the
above instructions.