Technical characteristics
Models GFE 631 GFI 632 - GFI 641
Dimensions (in mm)
Width (hole on the bottom side of the cabinet) 524 (496)
depth (hole on the bottom side of the cabinet) 289 (261)
height (min./max.) 152
Ø of exhausting connection 120
Weight (in kg) 7
Absorption (in watts - 220-240 V ~)
Rated absorption 280 215
Motor absorption 2 x 100 1 x 175
Lighting absorption (Halogen lamp) 2 x 40 2 x 20
Metal grease filter
Aspiration area (cm
2
) 704

GB
13
Electrical connection
! Warning: This appliance must be earthed.
Before installing the hood, it is vital to ensure that the
mains voltage corresponds to the voltage indicated on
the unit’s data plate.
! Only an authorised electrician should connect the
unit to the mains power supply.
! The unit is fitted with an electrical supply chord in
compliance with European standards.
Attention: if the appliance is permanently connected to
the mains, the plug supplied must be removed and
safely disposed of. The appliance must then be fitted
with a bipolar switch in compliance with current
regulations and have a minimum contact break of
3 mm
.
! The manufacturer will not be held liable for any
problems caused by the user’s failure to observe the
above instructions.