Getting Started With ATV320
• Unpack the drive and verify that it has not been damaged.
Damaged products or accessories may cause electric shock or unanticipated equipment operation.
Contact your local Schneider Electric sales office if you detect any damage whatsoever.
• Verify that the drive catalog number printed on the label is the same as that on the delivery note corresponding to the
purchase order.
• Write the drive Model Reference: ____________________ and Serial Number: _______________________
• For ATV320UppM2B, U0pN4B, U1pN4B, U22N4B...U30N4B, remove the output connector from the packaging and
verify that it has not been damaged.
DANGER
ELECTRIC SHOCK OR UNANTICIPATED EQUIPMENT OPERATION
Do not use damaged products or accessories.
Failure to follow these instructions will result in death or serious injury.
ATV320U15N4C
1.5kW-3HP-380/480V
8B 1512
4XXXXX
Download the manuals
You must have detailed information to be able to carry out the installation and commissioning.
This information can be found in the following manuals that can be downloaded on www.schneider-electric.com.
- The ATV320 Installation manual (NVE41289)
- The ATV320 Programming manual (NVE41295)
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
• Only appropriately trained persons who are familiar with and understand the contents of this manual and all other pertinent product
documentation and who have received safety training to recognize and avoid hazards involved are authorized to work on and with this drive
system. Installation, adjustment, repair and maintenance must be performed by qualified personnel.
• The system integrator is responsible for compliance with all local and national electrical code requirements as well as all other applicable
regulations with respect to grounding of all equipment.
• Many components of the product, including the printed circuit boards, operate with mains voltage.
• Only use properly rated, electrically insulated tools and measuring equipment.
• Do not touch unshielded components or terminals with voltage present.
• Motors can generate voltage when the shaft is rotated. Prior to performing any type of work on the drive system, block the motor shaft to
prevent rotation.
• AC voltage can couple voltage to unused conductors in the motor cable. Insulate both ends of unused conductors of the motor cable.
• Do not short across the DC bus terminals or the DC bus capacitors or the braking resistor terminals.
• Before performing work on the drive system:
- Disconnect all power, including external control power that may be present. Take into account that the circuit breaker or main switch does
not de-energize all circuits.
-Place a Do Not Turn On label on all power switches related to the drive system.
- Lock all power switches in the open position.
- Wait 15 minutes to allow the DC bus capacitors to discharge.
- Follow the instructions given in the chapter "Verifying the Absence of Voltage" in the installation manual of the product.
• Before applying voltage to the drive system:
- Verify that the work has been completed and that the entire installation cannot cause hazards.
- If the mains input terminals and the motor output terminals have been grounded and short-circuited, remove the ground and the short
circuits on the mains input terminals and the motor output terminals.
- Verify proper grounding of all equipment.
- Verify that all protective equipment such as covers, doors, grids is installed and/or closed.
Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by
Schneider Electric for any consequences arising out of the use of this material.
Information below is designed to use single drive connected to single asynchronous motor with a motor cable length less than 50 m (164 ft).
Verify your cables before connecting the drive with motor (length, power, shielded or unshielded).
2
Verify the delivery of the drive
3
Verify The Supply Mains Compatibility
• Verify that the supply mains is compatible with the supply range of the drive.
Line voltage _______ Volts Drive voltage range _______ Volts
Drive range: ATV320pppM2p = 200V single phase, ATV320pppM3C = 200 V three-phase, ATV320pppN4p = 400 V three-phase,
ATV320pppS6C = 600 V three-phase
www.schneider-electric.com 1/4 NVE21763 - 01/2020

Mount The Drive Vertically
u a u a
u 10 mm
0.39 in.
(1)Minimum value corresponding to thermal
contrainst.
(2)On ATV320U
ppM2B and ATV320pppN4B
(book form factor), a 150 mm (5.9 in)
clearance may help to connect the ground.
Catalog Number a (1)
ATV320U
ppM2B (2)
50 mm (2 in.)
ATV320U
ppM2C
ATV320
pppM3C
ATV320
pppN4p (2)
ATV320
pppS6C
ATV320
pppppW(S) 100 mm (4 in.)
1 ... 1.5 N·m
8.9 ... 13.3 lb.in
1.2 ... 1.5 N·m
10.6 ... 13.3 lb.in
0.8 ... 5 N·m
7.1 ... 44.2 lb.in
0.6 ... 0.8 N·m
5.3 ... 7.1 lb.in
200/240 V
380/500 V
525/600 V
200/240 V
OR
Asynchronous motor
ATV320UppM2B
ATV320pppN4B
ATV320UppM2p
ATV320pppM3C
ATV320UppN4p
ATV320pppS6C
ATV320pppppW(S)
OR
OR
For a surrounding air temperature up to 40 °C (104°F) up to 4 kHz.
See the ATV320 Installation manual (NVE41289) for other mounting and thermal conditions.
Connect The Drive: Power
• Connect the drive to the ground.
• Verify circuit breaker rating or fuse rating (see SCCR annex NVE21777)
• Verify that the nominal motor voltage is compatible with the drive voltage. Nominal motor voltage ______volts.
• Connect the drive to the motor.
• Connect the drive to the supply mains.
DANGER
HAZARD OF FIRE OR ELECTRIC SHOCK
• Wire cross sections and tightening torques must comply with the specifications provided in the installation manual.
• If you use flexible multi-wire cables for a connection with a voltage higher than 25 Vac, you must use ring type cable lugs or wire ferrules,
depending on the connection
Failure to follow these instructions will result in death or serious injury.
www.schneider-electric.com 2/4 NVE21763 - 01/2020