Section 2. Configuration
LCD Panel — Service Mode
The Service Mode allows the operator to set up the basic operation parameters of the printer and is entered from the Advanced Mode.
To Enter Advanced Mode:
STEP PROCEDURE
1. Press the LINE key while simultaneously turning the power on. When the printer emits one long beep, release the LINE key to display the first screen.
ADVANCED MODE
2. Press the LINE key twice to enter the Service Mode.
service mode
The Service Mode display indicates that the printer is in the Service
Mode. To advance to the first selection, press the FEED key.
Gap [X.XV]
gap [x.xv]
Input [X.XV}
input [x.xv]
The M-8400RVe printer determines the location of the leading edge of the label by measuring the difference between light levels when it sees either a label gap or a black "EYE" mark. This adjustment allows you to manually set the threshold voltage level between the maximum and minimum light levels. DIP switch DSW2-2 selects the sensor type. If DSW2-2 is in the OFF position, the setting will be for a See-Thru (or Gap) sensor and the LCD will display "GAP" on the top line along with the current setting. If DSW2-2 is in the ON position, the LCD will display "EYE" on the top line with its current setting. If the value entered for the bottom line setting is "0.0V", then the printer will automatically calculate the setting when the first label is fed after the printer is powered on or the head is closed. There are some instances where the automatically calculated value must be adjusted to ensure reliable label feeding, such as when the backing opacity or the reflectance of the "EYE" mark varies significantly within a roll of labels or between label rolls. In these instances the value should be set using the following procedures.
PN 9001094 Rev. A
SA T O M-8400RVe Service Manual
Page 2-25
Section 2. Configuration
LCD Panel — Service Mode
Gap [X.XV] Input [X.XV}
GAP - When setting the "GAP" threshold, the voltage shown on the top line of the display
must be measured with nothing but the backing in the sensor and then again with a label still attached to the backing. The formula to be used for setting the threshold is:
(High Voltage Level + Low Voltage Level) x 0.5 = Start Value
STEP PROCEDURE
1. Insert a label still attached to the backing into the sensor and close the Label Hold-Down. Record the voltage shown on the top line of the LCD panel. This line should have the message "GAP" on the top line (DIP switch DSW2-2 = OFF). Make sure the label is all the way under the sensor.
2. Strip the label from the backing and insert the backing strip under the sensor and close the Label Lid. Record the voltage shown on the top line of the LCD panel. The voltage ranges measured should be within the following range.
gap [x.xv] input [x.xv]
Backing without label = 0.5V or less Backing with label = 1.0V above the low value
If the measured values are outside this range, you may have trouble finding a value that will work properly under all conditions. If this is the case, a higher quality label may be needed to get adequate performance.
3. Calculate the starting point voltage using the formula.
4. Use the LINE key to step the counter to the desired setting. The display will increment one step for each time the LINE key is pressed. If the LINE key is held down for more than two seconds, it will automatically go into the fast scroll mode. The reading will advance to a setting of 3.3 (the maximum voltage) after which it will automatically wrap and start at "0.0" again. If a value of "0.0" is set, the printer will automatically set the level each time the printer is powered on with labels loaded or the head is closed.
5. Once the setting is correct, pressing the FEED key will accept the setting and advance to the Online Feed display.
Page 2-26
SA T O M-8400R Ve Service Manual
PN 9001094
Rev. A
LCD Panel — Service Mode
Section 2. Configuration
Eye [X.XV] Input [X.XV}
EYE - When setting the "EYE" threshold, the voltage must be measured with nothing but
the label under the sensor and then again with the printed "eye" mark under the sensor. The formula to be used for this is:
(High Voltage Level + Low Voltage Level) x 0.5 = Start Value
STEP PROCEDURE
1. Insert a label into the sensor and close the Label Hold-Down. Make sure the printed "eye" mark in not under the sensor. Record the voltage shown on the top line of the LCD panel. This line should have the message "EYE" on the top line (DIP switch DSW2-2 = ON).
2. Now pull the label forward until the "eye" mark is positioned under the sensor (the voltage reading should be at its highest point). Record the voltage shown on the top line of the LCD panel. The voltage ranges measured should be within the following ranges:
eye [x.xv] input [x.xv]
Label Only = 0.3 - 0.5V Eye-mark = Equal to or greater than 1.2V above the low value.
If the measured values are outside this range, you may have trouble finding a value that will work properly under all conditions. If this is the case, a higher quality label may be needed to get adequate performance.
3. Calculate the starting point voltage using the formula.
4. Use the LINE key to step the counter to the desired setting. The display will increment one step for each time the LINE key is pressed. If the LINE key is held down for more than two seconds, it will automatically go into the fast scroll mode. The reading will advance to a setting of 3.3 (the maximum voltage) after which it will automatically wrap and start at "0.0" again. If a value of "0.0" is set, the printer will automatically set the level each time the printer is powered on with labels loaded or the head is closed.
5. Once the setting is correct, pressing the FEED key will accept the setting and advance to the Auto Online Feed display.
PN 9001094 Rev. A
SA T O M-8400RVe Service Manual
Page 2-27