TECHNICAL DATA

&

FILE NO.

SERVICE MANUAL

XH2442 / CH2442

KH2442 / CH2442

XH3642 / CH3642

KH3642 / CH3642

XH4242 / CH4242

 

TH2442 / CH2442

UH2442 / CH2442

TH3642 / CH3642

UH3642 / CH3642

TH4242 / CH4242

 

SPLIT SYSTEM AIR CONDITIONER

INDOOR MODEL No.

PRODUCT CODE No.

XH2442

854 017 11

 

 

XH3642

854 017 12

 

 

XH4242

854 017 13

 

 

TH2442

854 017 14

 

 

TH3642

854 017 15

 

 

TH4242

854 017 16

 

 

KH2442

854 017 07

 

 

KH3642

854 017 08

 

 

UH2442

854 017 19

 

 

UH3642

854 017 20

 

 

OUTDOOR MODEL No.

PRODUCT CODE No.

CH2442

854 017 21

 

 

CH3642

854 017 22

 

 

CH4242

854 017 23

 

 

Indoor Unit

Outdoor Unit

 

 

 

XH2442

XH3642

TH2442

CH2442

 

XH4242

TH3642

 

 

 

TH4242

 

UH2442

UH3642

KH2442

 

 

 

KH3642

CH3642

 

 

 

 

 

 

CH4242

Sectio

1

2

3

4

5

85464849182000

REFERENCE NO. SM830082

Important

Please Read Before Starting

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-freeoperation, you must :

Carefully read this instruction booklet before beginning.

Follow each installation or repair step exactly as shown.

Observe all local, state, and national electrical codes.

Pay close attention to all warning and caution notices given in this manual.

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard or

CAUTION

unsafe practice which can result in personal injury or product or property damage.

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

When Wiring

……………………………………………………………………

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this system.

Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidentaly injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.

When Transporting

……………………………………………………………………

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.

When Installing

……………………………………………………………………

…In a Room

Properly insulate any tubing run inside a room to prevent

“sweating” that can cause dripping and water damage to walls and floors.

…In Moist or Uneven Locations

Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

…In an area with High Winds

Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

…In a Snowy Area (for Heat Pump-typeSys-tems)

Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When Connecting Refrigerant Tubing

……………………………………………………………………

Ventilate the room well, in the event that refrigerant gas leaks during the installation. Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of poisonous gas.

Keep all tubing runs as short as possible.

Use the flare method for connecting tubing.

Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-freeconnection.

Check carefully for leaks before starting the test run.

NOTE

Depending on the system type, liquid and gas lines may be either narrow or wide. Therefore, to avoid confusion the refrigerant tubing for your particular model is specified as either

“narrow” or “wide” rather than as “liquid” or “gas”.

When Servicing

……………………………………………………………………

Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site when installation is finished. Check that no metal scraps or bits of wiring have been left inside the unit.

CAUTION

Ventilate any enclosed areas when installing or testing the refrigeration system. Contact of refrigerant gas with fire or heat can produce poisonous gas.

Confirm after installation that no refrigerant gas is leaking. If the gas comes in contact with a burning stove, gas water heater, electric room heater or other heat source, it can cause the generation of poisonous gas.

SM830082

i

WHO SHOULD USE THIS MANUAL

This service manual is made to assist the service technician apply his knowledge and training to this model air conditioner. This manual is written both for experienced service persons andthose who are new to air conditioning service. To help those with less experience or who are new to this kind of unit we have included more explanations of basic procedures in simple language than is usual in some service manuals. Theexperienced technician will of course find he knows many of these things already and can go directly to the procedures and information he needs; the less experienced technician will better understand what to do even before he arrives on the job, and therefore be better able to work by himself as well as assist the more experienced technician.

TABLE OF CONTENTS

1. SPECIFICATIONS ............................................................................................

I -

1

1-1

Unit Specifications .....................................................................................

I -

2

1-2

Major Component Specifications ...............................................................

I - 12

(A) Indoor Units ..................................................................................................

I - 12

(B) Outdoor Units ...............................................................................................

I - 22

1-3

Other Component Specifications ...............................................................

I - 25

1-4

Dimensional Data ......................................................................................

I - 38

(A) Indoor Units ..................................................................................................

I - 38

(B) Outdoor Units ...............................................................................................

I - 47

1-5

Refrigerant Flow Diagram ..........................................................................

I - 49

1-6

Operating Range .......................................................................................

I - 50

1-7

Cooling Capacity........................................................................................

I - 51

1-8

Heating Capacity .......................................................................................

I - 71

1-9

Performance Charts...................................................................................

I - 72

1-10

Noise Criterion Curves...............................................................................

I - 90

1-11

Increasing the Fan Speed..........................................................................

I - 95

1-12

Air throw Distance Chart ............................................................................

I - 96

1-13

Installation Instructions ..............................................................................

I - 99

2. PROCESSES AND FUNCTIONS ......................................................................

II -

1

2-1

Room Temperature Control ......................................................................

II -

2

2-2Cold Draft Prevention (Heating Cycle)......................................................

II -

4

2-3Automatic Fan Speed (Indoor Unit) ..........................................................

II -

5

2-4Outdoor Fan Speed Control......................................................................

II -

6

2-5

Freeze Prevention (Cooling) .....................................................................

II -

7

2-6Condensing Temperature Control (Cooling) .............................................

II -

8

SM830082

ii

2-7

Overload Protection (Heating) ..................................................................

II -

9

2-8

Discharge Temperature Control (Cooling and Heating) ...........................

II - 10

2-9

Auto. Mode for Automatic Heating/Cooling Switching ..............................

II - 11

2-10

Defrosting Control, Outdoor Heat Exchanger Coil (Heating) ....................

II - 13

2-11

4-WayValve, Solenoid Control .................................................................

II - 14

2-12

Automatic Restart after Power Interruption...............................................

II - 15

2-13

Electronic Expansion Control Valve..........................................................

II - 16

2-14

Compressor Discharge Gas Temperature ................................................

II - 16

2-15

Compressor Current Detection Circuit ......................................................

II - 17

2-16

Electronic Expansion Valve ......................................................................

II - 18

2-17

Voltage Detection Control .........................................................................

II - 19

3. ELECTRICAL DATA ........................................................................................

III -

1

3-1

Indoor Unit (Electric Wiring Diagram, Schematic Diagram) .....................

III -

2

3-2

Outdoor Unit (Electric Wiring Diagram, Schematic Diagram) ..................

III - 12

4. SERVICE PROCEDURES ...............................................................................

IV -

1

4-1

Troubleshooting ......................................................................................

IV -

2

4-2

Checking the Electrical Components ......................................................

IV - 30

SM830082

iii

1. Specifications

1. SPECIFICATIONS

1-1

Unit Specifications .................................................................................

I -

2

 

4-WayAir DischargeSemi-concealedType ...........................................

I -

2

 

Ceiling Mounted Type ..............................................................................

I -

5

 

Concealed Duct Type ..............................................................................

I -

8

 

Wall-MountedType..................................................................................

I -

10

1-2

Major Component Specifications .............................................................

I -

12

 

(A) Indoor Units ........................................................................................

I -

12

 

(B) Outdoor Units .....................................................................................

I -

22

1-3

Other Component Specifications .............................................................

I -

25

 

4-WayAir DischargeSemi-concealedType ...........................................

I -

25

 

Ceiling Mounted Type ..............................................................................

I -

28

 

Concealed Duct Type ..............................................................................

I -

31

 

Wall-MountedType..................................................................................

I -

33

 

Outdoor Units...........................................................................................

I -

35

1-4

Dimensional Data ....................................................................................

I -

38

 

(A) Indoor Units ........................................................................................

I -

38

 

4-WayAir DischargeSemi-concealedType.......................................

I -

38

 

Ceiling Mounted Type ........................................................................

I -

40

 

Concealed Duct Type .........................................................................

I -

42

 

Wall-MountedType ............................................................................

I -

45

 

(B) Outdoor Units .....................................................................................

I -

47

1-5

Refrigerant Flow Diagram ........................................................................

I -

49

1-6

Operating Range .....................................................................................

I -

50

1-7

Cooling Capacity ......................................................................................

I -

51

1-8

Heating Capacity .....................................................................................

I -

71

1-9

Performance Charts .................................................................................

I -

72

 

(1) Operating Current ...............................................................................

I -

72

 

(2) Operating Pressure ............................................................................

I -

84

1-10Noise Criterion Curves .............................................................................

I -

90

1-11Increasing the Fan Speed........................................................................

I -

95

1-12Air throw distance chart ...........................................................................

I -

96

1-13

Installation Instructions ............................................................................

I -

99

 

Tubing Length ..........................................................................................

I -

99

 

SELECTING THE INSTALLATION SITE .................................................

I - 100

 

ELECTRICAL WIRING ............................................................................

I - 104

 

Electrical characteristics ..........................................................................

I - 108

1

2

3

4

5

SM830082

I - 1

1. Specifications

1-1Unit Specifications

1

2

3

4

5

 

MODEL No.

Indoor Unit

 

 

 

 

XH2442

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

CH2442

 

 

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE

 

 

 

Cooling

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity*

(17°F)**

BTU / h

24,000

 

23,400

 

25,000

 

24,300

 

 

 

 

 

 

 

 

16,400

 

15,800

 

Moisture removal (High)

 

Pints / h

8.6

 

8.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air circulation (H / M / L)

230 V

cu.ft. / min.

 

 

710 / 530 / 450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.E.E.R. (H.S.P.F.)

 

BTU / Wh

10.0

 

10.2

 

(7.0)

 

 

(7.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

VAC

230

 

208

 

230

 

208

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

VAC

 

 

 

187 - 253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

11.2

 

11.6

 

11.7

 

 

12.3

 

 

 

 

 

 

 

 

 

 

 

 

 

Power input*

 

 

W

2,450

 

2,350

 

2,500

 

 

2,450

 

 

(17°F)**

 

 

 

 

 

 

2,150

 

2,020

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum overcurrent protection

 

 

A

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

 

Microprocessor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low ambient control

 

 

 

 

 

 

Built-in0°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan speeds Indoor / Outdoor

 

 

 

 

3 and Automatic control / 3 (Auto)

 

 

 

 

 

 

 

 

 

 

 

Optional Wired Remote Controller (Timer)

 

 

 

RCS-SH80UG(72-hourON / OFF)

 

 

 

 

 

 

 

Optional Wireless Remote Controller (Timer)

 

 

RCS-SH80UA.WL /RCS-BH80UA.WL(72-hourON / OFF)

 

 

 

 

 

 

 

 

 

 

 

Air deflection

Horizontal / Vertical

 

 

— /Automatic

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

Washable, easy access, long life fiter (2,500 hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation sound

Indoor - Hi / Me / Lo

 

dB - A

 

 

38 / 35 / 31

 

 

 

 

 

Outdoor - Hi

 

dB - A

 

 

 

53

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

Electronic Expansion Control Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT PIPING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length

 

ft.

(m)

 

 

 

165 (50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length at shipment

 

ft.

(m)

 

 

 

100 (30)

 

 

 

 

 

 

 

 

 

 

Limit of elevation difference

 

ft.

(m)

Outdoor unit is higher than indoor unit: 165 (50)

 

between the two units

 

 

 

Outdoor unit is lower than indoor unit: 100 (30)

 

Refrigerant piping

Narrow pipe

in. (mm)

 

 

 

1 / 4 (6.35)

 

 

 

 

Flare type

Wide pipe

in. (mm)

 

 

3 / 4 (19.05)

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS & WEIGHT

 

 

 

Indoor unit

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

in. (mm)

12-1/8

 

(380)

 

28-15/16

(735)

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

30-9/16

 

(776)

 

37-1/32

(940)

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

30-9/16

 

(776)

 

13-3/8

(340)

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

49

 

(22)

 

157

(71)

 

 

 

 

 

 

 

 

 

 

 

Indoor grille dimensions

Height

in. (mm)

3-1/16

 

(78)

 

 

 

 

 

 

 

 

 

 

 

 

 

PNR-XHS2432

Width

in. (mm)

33-27/32

 

(860)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

33-27/32

 

(860)

 

 

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

11

 

(5)

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor / Outdoor unit

Height

in. (mm)

13-5/16

 

(338)

 

32-17/32

(826)

 

 

 

 

 

 

 

 

 

 

 

Package dimensions

Width

in. (mm)

32-7/8

 

(835)

 

40

(1,016)

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

33-9/32

 

(845)

 

16-3/8

(416)

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

57

 

(26)

 

170

(77)

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

8.4

 

(0.238)

 

12.3

(0.349)

 

Indoor grille

Height

in. (mm)

4-3/32

 

(104)

 

 

 

 

 

 

 

 

 

 

 

 

 

Package dimensions

Width

in. (mm)

37-15/16

 

(964)

 

 

 

 

 

 

 

 

 

 

 

 

 

PNR-XHS2432

Depth

in. (mm)

39-11/32

 

(999)

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

18

 

(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

3.5

 

(0.100)

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Cooling :

Rating conditions (*) : Room temperature 80 °F DB / 67°F WB, Ambient temperature 95°F DB / 75°F WB Heating :

Rating conditions (*) : Room temperature 70 °F DB / 60°F WB, Ambient temperature 47°F DB / 43°F WB Low temp conditions (**) : Room temperature 70°F DB / 60°F WB, Ambient temperature 17°F DB / 15°F WB

SM830082

I - 2

1. Specifications

1-1Unit Specifications

 

MODEL No.

Indoor Unit

 

 

 

 

XH3642

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

CH3642

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE

 

 

 

Cooling

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity*

(17°F)**

BTU / h

34,500

 

33,500

 

37,500

 

36,500

 

 

 

 

 

 

 

 

25,000

 

23,500

 

Moisture removal (High)

 

Pints / h

10.5

 

10.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air circulation (H / M / L)

230 V

cu.ft. / min.

 

 

1,050 / 840 / 720

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.E.E.R. (H.S.P.F.)

 

BTU / Wh

10.7

 

11.0

 

(7.0)

 

 

(7.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

VAC

230

 

208

 

230

 

208

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

VAC

 

 

 

187 - 253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

15.4

 

15.8

 

18.2

 

 

19.3

 

 

 

 

 

 

 

 

 

 

 

 

 

Power input*

 

 

W

3,350

 

3,200

 

3,850

 

 

3,750

 

 

(17°F)**

 

 

 

 

 

 

3,150

 

2,950

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum overcurrent protection

 

 

A

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

 

Microprocessor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low ambient control

 

 

 

 

 

 

Built-in0°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan speeds Indoor / Outdoor

 

 

 

 

3 and Automatic control / 3 (Auto)

 

 

 

 

 

 

 

 

 

 

 

 

Optional Wired Remote Controller (Timer)

 

 

 

RCS-SH80UG(72-hourON / OFF)

 

 

 

 

 

 

 

 

Optional Wireless Remote Controller (Timer)

 

 

RCS-SH80UA.WL /RCS-BH80UA.WL(72-hourON / OFF)

 

 

 

 

 

 

 

 

 

 

 

 

Air deflection

Horizontal / Vertical

 

 

— /Automatic

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

Washable, easy access, long life fiter (2,500 hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation sound

Indoor - Hi / Me / Lo

 

dB - A

 

 

44 / 37 / 33

 

 

 

 

 

Outdoor - Hi

 

dB - A

 

 

 

56

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

Electronic Expansion Control Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT PIPING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length

 

ft.

(m)

 

 

 

165 (50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length at shipment

 

ft.

(m)

 

 

 

100 (30)

 

 

 

 

 

 

 

 

 

 

 

Limit of elevation difference

 

ft.

(m)

Outdoor unit is higher than indoor unit: 165 (50)

 

between the two units

 

 

 

Outdoor unit is lower than indoor unit: 100 (30)

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant piping

Narrow pipe

in. (mm)

 

 

 

3 / 8 (9.52)

 

 

 

 

Flare type

Wide pipe

in. (mm)

 

 

3 / 4 (19.05)

 

 

 

 

DIMENSIONS & WEIGHT

 

 

 

Indoor unit

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

in. (mm)

14-1/2

 

(368)

 

48-5/8

(1,235)

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

41-31/32

 

(1,066)

 

37-1/32

(940)

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

30-9/16

 

(776)

 

13-3/8

(340)

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

60

 

(27)

 

203

(92)

 

 

 

 

 

 

 

 

 

 

 

Indoor grille dimensions

Height

in. (mm)

3-1/16

 

(78)

 

 

 

 

 

 

 

 

 

 

 

 

 

PNR-XHS2432

Width

in. (mm)

45-9/32

 

(1,150)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

33-27/32

 

(860)

 

 

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

15

 

(7)

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor / Outdoor unit

Height

in. (mm)

14-1/2

 

(368)

 

52-7/32

(1,326)

 

 

 

 

 

 

 

 

 

 

 

Package dimensions

Width

in. (mm)

44-9/32

 

(1,125)

 

40

(1,016)

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

33-9/32

 

(845)

 

16-3/8

(416)

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

71

 

(32)

 

227

(103)

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

12.4

 

(0.35)

 

19.8

(0.56)

 

Indoor grille

Height

in. (mm)

4-3/32

 

(104)

 

 

 

 

 

 

 

 

 

 

 

 

 

Package dimensions

Width

in. (mm)

49-1/2

 

(1,257)

 

 

 

 

 

 

 

 

 

 

 

 

 

PNR-XHS2432

Depth

in. (mm)

39-11/32

 

(999)

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

22

 

(10)

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

4.6

 

(0.131)

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Cooling :

Rating conditions (*) : Room temperature 80 °F DB / 67°F WB, Ambient temperature 95°F DB / 75°F WB Heating :

Rating conditions (*) : Room temperature 70 °F DB / 60°F WB, Ambient temperature 47°F DB / 43°F WB Low temp conditions (**) : Room temperature 70°F DB / 60°F WB, Ambient temperature 17°F DB / 15°F WB

SM830082

1

2

3

4

5

I - 3

1. Specifications

1-1Unit Specifications

1

2

3

4

5

 

MODEL No.

Indoor Unit

 

 

 

 

XH4242

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

CH4242

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE

 

 

 

Cooling

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity*

(17°F)**

BTU / h

42,000

 

40,000

 

44,000

 

42,000

 

 

 

 

 

 

 

 

28,000

 

26,000

 

Moisture removal (High)

 

Pints / h

14.4

 

14.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air circulation (H / M / L)

230 V

cu.ft. / min.

 

 

1,050 / 840 / 720

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.E.E.R. (H.S.P.F.)

 

BTU / Wh

10.4

 

10.4

 

(7.0)

 

 

(7.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

VAC

230

 

208

 

230

 

208

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

VAC

 

 

 

187 - 253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

20.6

 

21.0

 

21.7

 

 

22.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Power input*

 

 

W

4,200

 

4,100

 

4,450

 

 

4,350

 

 

(17°F)**

 

 

 

 

 

 

3,700

 

3,550

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum overcurrent protection

 

 

A

 

 

 

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

 

Microprocessor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low ambient control

 

 

 

 

 

 

Built-in0°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan speeds Indoor / Outdoor

 

 

 

 

3 and Automatic control / 3 (Auto)

 

 

 

 

 

 

 

 

 

 

 

Optional Wired Remote Controller (Timer)

 

 

 

RCS-SH80UG(72-hourON / OFF)

 

 

 

 

 

 

 

Optional Wireless Remote Controller (Timer)

 

 

RCS-SH80UA.WL /RCS-BH80UA.WL(72-hourON / OFF)

 

 

 

 

 

 

 

 

 

 

 

Air deflection

Horizontal / Vertical

 

 

— /Automatic

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

Washable, easy access, long life fiter (2,500 hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation sound

Indoor - Hi / Me / Lo

 

dB - A

 

 

45 / 38 / 34

 

 

 

 

 

Outdoor - Hi

 

dB - A

 

 

 

56

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

Electronic Expansion Control Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT PIPING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length

 

ft.

(m)

 

 

 

165 (50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length at shipment

 

ft.

(m)

 

 

 

100 (30)

 

 

 

 

 

 

 

 

 

 

Limit of elevation difference

 

ft.

(m)

Outdoor unit is higher than indoor unit: 165 (50)

 

between the two units

 

 

 

Outdoor unit is lower than indoor unit: 100 (30)

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant piping

Narrow pipe

in. (mm)

 

 

 

3 / 8 (9.52)

 

 

 

 

Flare type

Wide pipe

in. (mm)

 

 

3 / 4 (19.05)

 

 

 

 

DIMENSIONS & WEIGHT

 

 

 

Indoor unit

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

in. (mm)

14-1/2

 

(368)

 

48-5/8

(1,235)

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

41-31/32

 

(1,066)

 

37-1/32

(940)

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

30-9/16

 

(776)

 

13-3/8

(340)

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

60

 

(27)

 

203

(92)

 

 

 

 

 

 

 

 

 

 

 

Indoor grille dimensions

Height

in. (mm)

3-1/16

 

(78)

 

 

 

 

 

 

 

 

 

 

 

 

 

PNR-XHS2432

Width

in. (mm)

45-9/32

 

(1,150)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

33-27/32

 

(860)

 

 

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

15

 

(7)

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor / Outdoor unit

Height

in. (mm)

14-1/2

 

(368)

 

52-7/32

(1,326)

 

 

 

 

 

 

 

 

 

 

 

Package dimensions

Width

in. (mm)

44-9/32

 

(1,125)

 

40

(1,016)

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

33-9/32

 

(845)

 

16-3/8

(416)

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

71

 

(32)

 

227

(103)

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

12.4

 

(0.35)

 

19.8

(0.56)

 

Indoor grille

Height

in. (mm)

4-3/32

 

(104)

 

 

 

 

 

 

 

 

 

 

 

 

 

Package dimensions

Width

in. (mm)

19-1/2

 

(1,257)

 

 

 

 

 

 

 

 

 

 

 

 

 

PNR-XHS2432

Depth

in. (mm)

39-11/32

 

(999)

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

22

 

(10)

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

4.6

 

(0.131)

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Cooling :

Rating conditions (*) : Room temperature 80 °F DB / 67°F WB, Ambient temperature 95°F DB / 75°F WB Heating :

Rating conditions (*) : Room temperature 70 °F DB / 60°F WB, Ambient temperature 47°F DB / 43°F WB Low temp conditions (**) : Room temperature 70°F DB / 60°F WB, Ambient temperature 17°F DB / 15°F WB

SM830082

I - 4

1. Specifications

1-1Unit Specifications

 

MODEL No.

 

Indoor Unit

 

 

 

 

TH2442

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

CH2442

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE

 

 

 

Cooling

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity*

(17°F)**

BTU / h

22,400

 

21,600

 

25,400

 

25,000

 

 

 

 

 

 

 

 

 

15,700

 

15,000

 

Moisture removal (High)

 

Pints / h

8.0

 

7.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air circulation (H / M / L)

230 V

cu.ft. / min.

 

 

550 / 490 / 460

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.E.E.R. (H.S.P.F.)

 

BTU / Wh

10.0

 

10.0

 

(7.0)

 

 

(7.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

VAC

230

 

208

 

230

 

 

208

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

VAC

 

 

 

187 - 253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

10.7

 

11.3

 

11.7

 

 

12.9

 

 

 

 

 

 

 

 

 

 

 

 

 

Power input*

 

 

W

2,350

 

2,280

 

2,550

 

 

2,500

 

 

 

(17°F)**

 

 

 

 

 

 

2,070

 

2,040

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum overcurrent protection

 

 

A

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

 

Microprocessor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low ambient control

 

 

 

 

 

 

Built-in0°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan speeds Indoor / Outdoor

 

 

 

 

3 and Automatic control / 3 (Auto)

 

 

 

 

 

 

 

 

 

 

 

Optional Wired Remote Controller (Timer)

 

 

 

RCS-SH80UG(72-hourON / OFF)

 

 

 

 

 

 

 

Optional Wireless Remote Controller (Timer)

 

 

RCS-SH80UA.WL /RCS-BH80UA.WL(72-hourON / OFF)

 

 

 

 

 

 

 

 

 

 

 

 

Air deflection

Horizontal / Vertical

 

 

Manual / Automatic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

Washable, easy access

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation sound

 

Indoor - Hi / Me / Lo

 

dB - A

 

 

40 / 38 / 36

 

 

 

 

 

 

Outdoor - Hi

 

dB - A

 

 

 

53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

Electronic Expansion Control Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT PIPING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length

 

ft.

(m)

 

 

 

165 (50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length at shipment

 

ft.

(m)

 

 

 

100 (30)

 

 

 

 

 

 

 

 

 

 

 

Limit of elevation difference

 

ft.

(m)

Outdoor unit is higher than indoor unit: 165 (50)

 

between the two units

 

 

 

Outdoor unit is lower than indoor unit: 100 (30)

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant piping

 

Narrow pipe

in. (mm)

 

 

 

1 / 4 (6.35)

 

 

 

 

Flare type

 

Wide pipe

in. (mm)

 

 

3 / 4 (19.05)

 

 

 

 

DIMENSIONS & WEIGHT

 

 

 

Indoor unit

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

Unit dimensions

 

Height

in. (mm)

7-15/32

 

(190)

 

28-15/16

(735)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

51-3/16

 

(1,300)

 

37-1/32

(940)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

26-3/8

 

(670)

 

13-3/8

(340)

 

 

 

 

 

 

 

 

 

 

 

 

Indoor grille dimensions

 

Height

in. (mm)

9-7/16

 

(240)

 

32-17/32

(826)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

54-19/32

 

(1,387)

 

40

(1,016)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

29-31/32

 

(761)

 

16-3/8

(416)

 

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

60

 

(27)

 

157

(71)

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

77

 

(35)

 

170

(77)

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

8.9

 

(0.253)

 

12.3

(0.349)

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Cooling :

Rating conditions (*) : Room temperature 80 °F DB / 67°F WB, Ambient temperature 95°F DB / 75°F WB Heating :

Rating conditions (*) : Room temperature 70 °F DB / 60°F WB, Ambient temperature 47°F DB / 43°F WB Low temp conditions (**) : Room temperature 70°F DB / 60°F WB, Ambient temperature 17°F DB / 15°F WB

1

2

3

4

5

SM830082

I - 5

1. Specifications

1-1Unit Specifications

1

2

3

4

5

 

MODEL No.

 

Indoor Unit

 

 

 

 

TH3642

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

CH3642

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE

 

 

 

Cooling

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity*

(17°F)**

BTU / h

34,000

 

33,000

 

40,000

 

39,000

 

 

 

 

 

 

 

 

 

25,000

 

24,000

 

Moisture removal (High)

 

Pints / h

10.7

 

10.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air circulation (H / M / L)

230 V

cu.ft. / min.

 

 

1,100 / 930 / 750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.E.E.R. (H.S.P.F.)

 

BTU / Wh

10.4

 

10.7

 

(7.3)

 

 

(7.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

VAC

230

 

208

 

230

 

 

208

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

VAC

 

 

 

187 - 253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

15.1

 

15.7

 

18.2

 

 

19.6

 

 

 

 

 

 

 

 

 

 

 

 

 

Power input*

 

 

W

3,350

 

3,170

 

3,950

 

 

3,890

 

 

 

(17°F)**

 

 

 

 

 

 

3,000

 

2,900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum overcurrent protection

 

 

A

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

 

Microprocessor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low ambient control

 

 

 

 

 

 

Built-in0°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan speeds Indoor / Outdoor

 

 

 

 

3 and Automatic control / 3 (Auto)

 

 

 

 

 

 

 

 

 

 

Optional Wired Remote Controller (Timer)

 

 

 

RCS-SH80UG(72-hourON / OFF)

 

 

 

 

 

 

Optional Wireless Remote Controller (Timer)

 

 

RCS-SH80UA.WL /RCS-BH80UA.WL(72-hourON / OFF)

 

 

 

 

 

 

 

 

 

 

 

Air deflection

Horizontal / Vertical

 

 

Manual / Automatic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

Washable, easy access

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation sound

 

Indoor - Hi / Me / Lo

 

dB - A

 

 

46 / 42 / 37

 

 

 

 

 

 

Outdoor - Hi

 

dB - A

 

 

 

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

Electronic Expansion Control Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT PIPING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length

 

ft.

(m)

 

 

 

165 (50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of piping length at shipment

 

ft.

(m)

 

 

 

100 (30)

 

 

 

 

 

 

 

 

 

 

Limit of elevation difference

 

ft.

(m)

Outdoor unit is higher than indoor unit: 165 (50)

 

between the two units

 

 

 

Outdoor unit is lower than indoor unit: 100 (30)

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant piping

 

Narrow pipe

in. (mm)

 

 

 

3 / 8 (9.52)

 

 

 

 

Flare type

 

Wide pipe

in. (mm)

 

 

3 / 4 (19.05)

 

 

 

 

DIMENSIONS & WEIGHT

 

 

 

Indoor unit

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

Unit dimensions

 

Height

in. (mm)

9-7/16

 

(240)

 

48-5/8

(1,235)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

62-1/32

 

(1,575)

 

37-1/32

(940)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

26-3/8

 

(670)

 

13-3/8

(340)

 

 

 

 

 

 

 

 

 

 

 

 

Indoor grille dimensions

 

Height

in. (mm)

12-15/32

 

(317)

 

52-7/32

(1,326)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

66-1/16

 

(1,678)

 

40

(1,016)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

31-1/16

 

(789)

 

16-3/8

(416)

 

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

90

 

(41)

 

203

(92)

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

104

 

(47)

 

227

(103)

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

14.8

 

(0.42)

 

19.8

(0.56)

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Cooling :

Rating conditions (*) : Room temperature 80 °F DB / 67°F WB, Ambient temperature 95°F DB / 75°F WB Heating :

Rating conditions (*) : Room temperature 70 °F DB / 60°F WB, Ambient temperature 47°F DB / 43°F WB Low temp conditions (**) : Room temperature 70°F DB / 60°F WB, Ambient temperature 17°F DB / 15°F WB