Samsung Svr-17B, Svr-17A, SV-A10G-CIS Reference Information

Samsung Electronics 2-1
2. Reference Information
2-1 Servicing Jigs and Special Tools
1. For this VCP chassis, the program switch and the sensors (start/end/reel) are located on the main PCB, not on the deck assÕy.
2. As long as the deck assÕy is connected to the main PCB, all repairs are possible. Important : In order to repair the main PCB without the deck assÕy connected, the X-5 chassis jig should be used.
3. To emulate the function of the sensors, plug the power cord to outlet with pressing SW711 on the function PCB.
4. The X-5 chassis jig can be used for the following :
1) When repairing or confirming the operation of the deck assÕy.
2) When replacing or repairing the components located under the deck assÕy.
3) When repairing the function PCB.
5. The X-5 chassis jig can not be used for the following :
1) Repairing defects in the video section.
2) Repairing defects in the audio section.
3) If the defect is related to tape speed.
Note : Accurate repair may not be possible due to
external noise between the deck assÕy and main PCB.
2-1-1 Servicing guide
X-5 Chassis Jig
Jig Item
68140-500-013
Part No.
Connects the deck ass’y to the main PCB connecting cable.
Use
2-1-2 Servicing Jig
Reference Information
2-2 Samsung Electronics
2-1-4 How to Connect X-5 chassis jig
4. Insert wafers of drum motor, capstan motor and loading motor on X-5 chassis jig into each of the connectors of deck assÕy, and then secure with three screws.
5. Solder the 3 leads of the jig cable to ÒSERVICE OPTIONÓ on the main PCB.
6. Apply power to the function PCB.
7. Insert a test tape into the housing assÕy.
8. Simultaneously touch the start and end sensor LEDs on the PCB, so that the tape loads automatically. After the tape is loaded, all of the function buttons on the function PCB can be used.
9. If the test tape is ejected while the jig is in use, attempt to re-load the tape by simultaneously touching the start and end sensor LEDs.
Note : After completing repairs, unplug and plug the power cord in order to reset.
1. Unplug the power cord from AC outlet.
2. Remove the deck assÕy from main PCB (See Page 4-4 of service manual).
3. To emulate the function of the sensors, plug the power cord to outlet with pressing SW711 on the function PCB (See diagram below).
The location of SVC OPTION(SW711) is same on the function PCB regardless of model.
Function (Component side)
Reference Information
Samsung Electronics 2-3
CONNECTS TO THE MAIN PCB CN604.
CONNECTS TO THE MAIN PCB SVC OPTION.
CONNECTS TO THE MAIN PCB CN606.
CONNECTS TO THE MAIN PCB CN601.
CONNECTS TO THE DRUM MOTOR CONNECTOR OF DECK ASS'Y.
CONNECTS TO THE CAPSTAN MOTOR CONNECTOR OF DECK ASS'Y.
CONNECTS TO THE LOADING MOTOR CONNECTOR OF DECK ASS'Y.
DECK ASS'Y
MAIN BOARD
1 SCREW (1-3X10)
2 SCREWS (2-3X10)
CN604
CN606
SVC OPTION
CN601
How to Connect X-5 chassis jig
Loading...
+ 5 hidden pages