Samlex PST-3000-12, PST-3000-24 Specs

3000W
MODEL NO. PST-3000-12 PST-3000-24
OUTPUT
OUTPUT VOLTAGE 120 VAC ± 3% 120 VAC ± 3%
MAXIMUM OUTPUT CURRENT 25A 25A
OUTPUT FREQUENCY 60 Hz ± 1% 60 Hz ± 1%
TYPE OF OUTPUT WAVEFORM Pure Sine Wave Pure Sine Wave
TOTAL HARMONIC DISTORTION OF OUTPUT WAVEFORM < 3% < 3%
CONTINUOUS OUTPUT POWER
(At Power Factor = 1) 3000 Watts 3000 Watts
SURGE OUTPUT POWER 6000 Watts (< 8 ms) 6000 Watts (< 8 ms)
PEAK EFFICIENCY > 85% > 88%
AC OUTPUT CONNECTIONS
NEMA5-20R GFCI Duplex Outlets, Terminal Block for hardwiring
NEMA5-20R GFCI Duplex Outlets, Terminal Block for hardwiring
INPUT
NOMINAL DC INPUT VOLTAGE 12V 24V
DC INPUT VOLTAGE RANGE 10.7 - 16.5 VDC 21.4 - 33 VDC
MAXIMUM INPUT CURRENT 360A 180A
DC INPUT CURRENT AT NO LOAD < 1.6A < 1.0A
DC INPUT CONNECTIONS Bolt & Nut: 5/16” x 18 TPI Bolt & Nut: 5/16” x 18 TPI
DC INPUT FUSES (INTERNAL) 12 X 30A = 360A (Each Type ATC, 32V, 30A) 12 x 15A = 180A (Each Type ATC, 32V, 15A)
DISPLAY LED Power, Overload, Over Temperature Power, Overload, Over Temperature
PROTECTIONS
LOW DC INPUT VOLTAGE ALARM 10.7V ± 0.1V 21.4V ± 0.2V
LOW DC INPUT VOLTAGE SHUTDOWN 10V ± 0.1V ; Auto-reset: 11.5V ± 0.3V 20V ± 0.2V ; Auto-reset: 23V ± 0.5V
HIGH DC INPUT VOLTAGE SHUTDOWN 16.5V ; Auto-reset: < 16.5V 33V ; Auto-reset: < 33V
SHORT CIRCUIT SHUTDOWN When output voltage drops to 80VAC or lower for 1 to 1.5 sec
OVERLOAD SHUTDOWN At overload of 110% to 115% for 2 to 2.5 sec
GROUND FAULT SHUTDOWN Only on GFCI outlets (5 to 6 mA leakage)
OVER TEMPERATURE SHUTDOWN 90°C ± 5°C (Sensed at Transformer T3) ; Auto-reset at 65°C ± 5°C
REVERSE POLARITY ON DC INPUT SIDE External / internal DC sides fuses will blow
REMOTE
CONTROL
WIRED REMOTE CONTROL WITH LED / LED DISPLAY
WIRED ON / OFF CONTROL
RC-300 (sold separately) with 25’ cable (i) By switching external contact (ii) By switching external 12V/24V signal
COOLING FORCED AIR COOLING
Temperature controlled fan (Sensed at Transformer T6) Fan ON at 55°C ± 3°C; Fan OFF at 45°C ± 3°C
COMPLIANCE
SAFETY
Intertek - ETL Listed. Conforms to UL Standard 458 and certied to CSA Std. C22.2 No. 107.1
EMI / EMC FCC Part 15(B), Class A
ENVIRONMENT OPERATING TEMPERATURE RANGE
Operating temperature -20 to 40C / -4 to 104F Storage temperature -30 to 70C / -22 to 158F 90% relative humidity non-condensing
DIMENSIONS
(W X D X H), MM 263 x 456.5 x 145 263 x 456.5 x 145
(W X D X H), INCHES 10.35 x 17.97 x 5.71 10.35 x 17.97 x 5.71
WEIGHT
KG 9.8 9.8
LBS 21.6 21.6
Clean and reliable AC Power identical to household electricity. Commercial grade design suitable for heavy duty loads & long periods of continuous operation.
3 YEAR LIMITED WARRANTY
DC-AC Inverter
Pure Sine Wave
Model PST-3000-12
12 VDC- 120 VAC
PST-3000-24
24 VDC- 120 VAC
- High efciency & low RF emissions
- Can be hard wired
- 2x Surge
- Wide DC input range
- Dual GFCI Protected Outlets
- Wide temperature operating range -20 to +40°C / -4 to +104°F
- Temperature controlled cooling fan
- Low idle power draw
- Remote Input – Use to turn inverter ON or OFF with ignition start or any other Remote ON/OFF switch
- Optional LCD remote control, model RC-300
- UPC – Universal Protection Circuit: low voltage, over voltage, over temperature, over load and short circuit
- Safety certied to UL & CSA standards, FCC compliant
To view a full selection of Samlex products visit our website at www.samlexamerica.com or contact us: 1-800-561-5885 or sales@samlexamerica.com
12001-PST-3000-12-24-1221NOTE: Specications are subject to change without notice
Loading...