SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
Page 3
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
3
CONTENTS
INTRODUCTION 5
SAFETY INSTRUCTIONS 6
GENERAL DESCRIPTION 7
INSTALLATION PROCEDURE 10
STAGE 1 : DRILLING THE CHASSIS MOUNTING HOLES 10 STAGE 2 : CABLE ENTRY HOLE LOCATION AND CHASSIS FIXATION 11 STAGE 3 : CONNECTING THE COVER ASSEMBLY TO THE CHASSIS 12 STAGE 4: CLOSING MORPHOACCESS™ 13
ELECTRICAL INTERFACE 14
TERMINAL BLOCK BOARD WIRING 14 POWER SUPPLY CABLE 16 WIEGAND OUTPUT WIRING 16 DATA CLOCK OUTPUT WIRING 17 COM RS485 SERIAL PORT 17 ETHERNET WIRING 18 OUTPUT RELAY 19 TAMPER SWITCH 19
USER INTERFACE 20
RECOMMENDATIONS 21
APPENDIX 1 - FINGERPRINT PLACEMENT RULES 23
APPENDIX 2 - BIBLIOGRAPHY 24
APPENDIX 3 - DRILLING TEMPLATE 25
Page 4
4
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
Page 5
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
5
IINNTTRROODDUUCCTTIIOONN
Congratulations for choosing the SAGEM MorphoAccess™1 Automatic Fingerprint Recognition Terminal. MorphoAccess™ provides an innovative and effective solution for access control applications using Fingerprint Verification or/ and Identification.
Among a range of alternative biometric techniques, the use of finger imaging has significant advantages : each finger constitutes an unalterable physical signature which develops before birth and is preserved until death. Unlike DNA, a finger image is unique to each individual - even identical twins.
The MorphoAccess™ terminal integrates SAGEM image processing and feature matching algorithms (MorphoSoft™ and MorphoImaging™). This technology is based on lessons learned during more than 20 years of experience in the field of biometric identification and the creation of literally millions of individual fingerprint identification records.
We believe you will find the SAGEM MorphoAccess™ fast, accurate, easy to use and suitable for physical access control.
The SAGEM MorphoAccess™ offers the following advantages:
High quality optical sensor.
Supports multiple input/output interfaces used in the physical
access control industry.
Local area network interface for easy interaction with other host systems.
Very compact size for easy installation and integration into your available office space.
Open architecture, with dedicated applications implemented via MA1xx Software Development Kit.
To ensure the most effective use of your SAGEM MorphoAccess™, we recommend that you read this Installation Guide totally.
1
The SAGEM logo and trademark are the property of SAGEM Défense Sécurité.
All other trademarks or product names are trademarks or product names of the respective title holders.
Page 6
6
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
SSAAFFEETTYY IINNSSTTRRUUCCTTIIOONNSS
The installation of this product should be made by a qualified service Person and should conform to all local codes.
It is strongly recommended to use a class II power supply at 12 V ±5% and
0.5 A. min according with Safety Electrical Low Voltage (SELV). The 12 V power supply cable length should not exceed 5 meters.
This product is intended to be installed with a power supply conformed to EN60950, in accordance with the NEC Class 2 requirements ; or supplied by a listed EN60950 external Power Unit marked Class 2 , Limited Power source, or LPS and rated 12 V DC, 0.5 A minimum.
In case of building to building connection it is recommended to connect 0V to ground. Ground cable must be connected with the terminal block 0V GND.
Europe information’s : SAGEM hereby declares that the SAGEM MorphoAccess™ has been tested and found compliant with the below listed standards as required by the EMC Directive 89/336/EEC: EN55022 (1994) / EN55024 (1998) , EN300-330 (1999) and by the low voltage Directive 73/23/EEC amended by 93/68/EEC: EN60950 (2000).
USA information’s : This equipment has been tested and found compliant with Class B digital device requirements, pursuant to part 15 of the FCC Rules. These requirements are designed to ensure reasonable protection against harmful RF interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may interfere with radio communications. If this equipment interferes with radio or television reception - which can be determined by disconnecting and re­connecting the unit – the user is encouraged to try to correct the interference by one or more of the following measures :
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Page 7
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
7
GGEENNEERRAALL DDEESSCCRRIIPPTTIIOONN
Contactless Card reade
r
( depending of the versions)
Optical Senso
r
Cable entry
Mounting keyholes
Tamper switch
Power supply cable
Trap door
Terminal Block
Page 8
8
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
MorphoAccess™ supplies :
1 Cover assembly 1 Chassis
1 Trap door 2 screws for cover fixation
1 secured screwdriver Torx 20 1 secured screw for trap door fixation
Qty
1 Cover assembly
1 Chassis
Page 9
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
9
1 Trap door
2 Screws for cover fixation
into the chassis.
1 Secured screw for trap
door fixation
1 Secured screwdriver
Torx 20
In order to proceed to MorphoAccess installation , you’ll need a standard 2,5mm screwdriver.
Page 10
10
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
IINNSSTTAALLLLAATTIIOONN PPRROOCCEEDDUURREE
SSttaaggee 11 :: DDrriilllliinngg tthhee cchhaassssiiss mmoouunnttiinngg hhoolleess
I. For choice, drill the 4 corners holes (a) for the screws for the mounting
keyholes so that the cable entry is in a suitable position for your cabling, using the dimensional drawing above.
II. In case of electric plug connections , MorphoAccess™ terminal may be
installed directly on US or European plugs , with some of the 5 holes (b). So, drill the needed holes.
(a) Screw : 4 mm
(b) Screw : 3 mm
Page 11
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
11
SSttaaggee 22 :: CCaabbllee eennttrryy hhoollee llooccaattiioonn aanndd cchhaassssiiss ffiixxaattiioonn
I. Pass the all connecting cables through the 2 cable entry. Be sure during
manipulation that power supply from electric source is off.
II. Fit the screws chassis fixation.
The mounting screws must be 4 mm diameter maximum for corner place (a) and 3 mm diameter maximum for other places (b).
Small head screws are required.
Cable entr
y
Cable entr
y
Page 12
12
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
SSttaaggee 33 :: CCoonnnneeccttiinngg tthhee ccoovveerr aasssseemmbbllyy ttoo tthhee cchhaassssiiss
I. Pass all connecting cable into cover entry holes.
II. Put the cover assembly into the chassis hanging
III. Fit the 2 screws chassis fixation , supplied with MorphoAccess™
IV. Connect cables to terminal blocks (see the detailed instructions in
the following sections)
Screw chassis fixation
Screw chassis fixation
( II )
Page 13
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
13
SSttaaggee 44:: CClloossiinngg MMoorrpphhooAAcccceessss™™
I. Push up the trap door along the cover assembly
II. Fit the M4x20 assembly secured screw ( use screwdriver Torx 20S
supplied with MorphoAccess™ )
( I )
( II )
Page 14
14
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
EELLEECCTTRRIICCAALL IINNTTEERRFFAACCEE
TTeerrmmiinnaall bblloocckk bbooaarrdd wwiirriinngg
Power supply sourceUSB master connecto
r
Various interfaces
Page 15
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 1 TR- / D1 Out Wiegand D1 or RS485 TX/RX- or CLK
Pin 2 TR+ / D0 Out Wiegand D0 or RS485 TX/RX+ or Data
Pin 3 LED1 In Wiegand LED1
Pin 4 LED2 In Wiegand LED2
Pin 5 GND Ground for Wiegand / RS485 / Dataclock
Pin 6 Relay C0 Contact Relay 0
Pin 7 Relay C1 Contact Relay 1
Pin 8 TSW0 Tamper switch Contact 0
Pin 9 TSW1 Tamper switch Contact 1
Pin 10 GND Ground for Ethernet Interface (LAN 10/100 Mbps)
Pin 11 RX- Receive negative Ethernet
Pin 12 RX+ Receive positive Ethernet
Pin 13 TX- Transmit negative Ethernet
Pin 14 TX+ Transmit positive Ethernet
Pin 15 +12V Positive 12 Volts , power supply.
Pin 16 GND Ground power supply.
USB
Page 16
16
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
PPoowweerr ssuuppppllyy ccaabbllee
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 15 +12V Positive 12 Volts , power supply.
Pin 16 GND Ground power supply.
Power supply :
Must be conformed to CEE/EEC EN60950 standard
12 Volts ± 5% (regulated) 0.5 Amp.
It could be coming from 12 Volts Wiegand power supply , conforms to the Security Industry Association's Wiegand standard March 1995.
WWiieeggaanndd oouuttppuutt wwiirriinngg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 1 TR- / D1 Out Wiegand D1
Pin 2 TR+ / D0 Out Wiegand D0
Pin 3 LED1 In Wiegand LED1 ( option )
Pin 4 LED2 In Wiegand LED2 ( option )
Pin 5 GND Ground for Wiegand / RS485 / Dataclock
Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V TTL compatible.
Page 17
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
17
DDaattaa CClloocckk oouuttppuutt wwiirriinngg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 1 TR- / D1 Out Clock
Pin 2 TR+ / D0 Out Data
Pin 5 GND Ground for Wiegand / RS485 / Dataclock
The electrical interface is 5V TTL compatible.
CCOOMM RRSS448855 sseerriiaall ppoorrtt
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 1 TR- / D1 Out RS485 TX/RX-
Pin 2 TR+ / D0 Out RS485 TX/RX+
Pin 5 GND Ground for Wiegand / RS485 / Dataclock
For a half-duplex RS485 connection, only Tx/Rx+ , Tx/Rx- and ground reference signals are necessary.
Depending on RS485 network , an impedance adaptation may be required.
A 120 Ohms resistor termination may be added to the terminal , by strapping pin 1 and pin 2 of the auxiliary connector.
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Page 18
18
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
EEtthheerrnneett wwiirriinngg
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 10 GND Ground for Ethernet Interface (LAN 10/100 Mbps)
Pin 11 RX- Receive negative Ethernet
Pin 12 RX+ Receive positive Ethernet
Pin 13 TX- Transmit negative Ethernet
Pin 14 TX+ Transmit positive Ethernet
RJ 45 cabling recommendation :
RJ45 plug pinout is compliant with 10 base T , IEEE802.3 Specification.
Pinout Signals
EIA/TIA
T568B color
EIA/TIA
T568A color
Corel L120
color
1 TD(+) Transmit Data Plus
(Output)
White Orange White Green Grey
2 TD(-) Transmit Data Minus
(Output)
Orange Green White
3 RX(+) Receive Data Plus
(Input)
White Green White Orange Pink
4 No connection Blue Blue Orange
5 No connection White blue White blue Yellow
6 RX(-) Receive Data Minus
(Input)
Green Orange Blue
7 Ground protection ( option ) White Brown White Brown Purple
8 No connection Brown Brown Brown
Page 19
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
19
OOuuttppuutt rreellaayy
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 6 Relay C0 Contact Relay 0
Pin 7 Relay C1 Contact Relay 1
Relay ratings
1 A at 30 VDC according to the safety extra low voltage requirements (42.4 VAC max, 60 VDC max) independently of the power supply.
TTaammppeerr sswwiittcchh
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 8 TSW0 Tamper switch Contact 0
Pin 9 TSW1 Tamper switch Contact 1
Tamper-switch ratings
50 mA at 20 VDC max according to the safety extra low voltage.
Page 20
20
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
UUSSEERR IINNTTEERRFFAACCEE
MorphoAccess™ terminal works upon three principles : Access control with identification, access control with authentication, and proxy mode.
These three principles consist in five functional modes :
Mode 0 : Local identification (fingerprint capture) with a local base,
MA100 default mode
Mode 1 : Reserved
Mode 2 : Proxy mode; Command sending to the MorphoAccess™
Mode 3 : Authentication (contactless card reading minutiae) and
fingerprint capture
MA100 and MA120 default mode
Mode 4 : Authentication (contactless card reading ID) and fingerprint capture with a local base
Mode 5 : Modes 0 and 3, merged
Mode 6: Reserved
The MorphoAccess™ 1xx series manage one base of 500 persons with 2 fingers, locally or remotely.
Page 21
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
21
RReeccoommmmeennddaattiioonnss
AArreeaass ccoonnttaaiinniinngg ccoommbbuussttiibblleess
It is strongly recommended that you do not install your SAGEM MorphoAccess™ in the vicinity of gas stations, petroleum processing facilities or any other facility containing flammable or combustible gasses or materials.
GGeenneerraall pprreeccaauuttiioonnss
Do not attempt to repair your SAGEM MorphoAccess™ yourself. The manufacturer cannot be held responsible for any damage/accident that may result from attempts to repair components. Any work carried out by non-authorized personnel will invalidate your warranty.
Do not use your SAGEM MorphoAccess™ in damp areas (swimming pool...). Protect it from water and other liquids.
Do not expose your SAGEM MorphoAccess™ to extreme temperatures.
Use your SAGEM MorphoAccess™ with original accessories. Attempts to integrate the MorphoAccess™ with unapproved accessories will void your warranty.
Due to electrostatic discharge, and depending on the environment, synthetic carpet should be avoided in areas where the SAGEM MorphoAccess™ has been installed.
EEtthheerrnneett ccoonnnneeccttiioonn
It is recommended to use a category 5 shielding cable (120 OHM). It is also strongly recommended to insert a repeater unit every 90 m.
Extreme care must be taken while connecting Ethernet wire to the terminal block board since low quality connection may strongly impact Ethernet signal sensibility.
It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do the same with Tx+/Tx- and the other twisted-pair wire).
DDaattee // TTiimmee ssyynncchhrroonniissaattiioonn
If you except to use the MorphoAccessTM for application requiring high time precision we recommend to synchronize regularly your terminal time with an external clock.
The terminal clock has a 40 10-6 ppm time deviation.
Page 22
22
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
CClleeaanniinngg pprreeccaauuttiioonnss
A dry cloth should be used.
WWaarrnniinngg
The manufacturer cannot be held responsible if the above recommendations are not followed or if the SAGEM MorphoAccess™ is incorrectly used.
Biometrics Terminals Hot-Line
To Access this service, please call us in order to get your login. Please send email rather call the hot-line.
Email: hotline.biometrics@sagem.com
Tel : + 33 1 34 30 39 19 (Monday to Friday, 9H00am to 6H00pm )
Page 23
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
23
AAPPPPEENNDDIIXX 11 -- FFIINNGGEERRPPRRIINNTT PPLLAACCEEMMEENNTT RRUULLEESS
To ensure a good quality contact of your finger on the terminal you must leave your finger on the sensor until sensor light is turned off.
Fingerprint Placement Fingerprint Orientation
Area containing most of the information
Fingerprint Inclination
Fingerprint Rotation
Page 24
24
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000034370-01
AAPPPPEENNDDIIXX 22 -- BBIIBBLLIIOOGGRRAAPPHHYY
Configration Guide : MA1xx Series
This guide gives all informations about terminal parameters.
MorphoAccess Host System Interface Specifications
Describes MorphoAccessTM communication protocol (Serial and Ethernet).
MorphoAccess Remote Messages Specifications
Complete specifications describing remote messages send during control (Wiegand, Dataclock, Ethernet and Serial).
Finger Positioning
Highlight finger-positioning principles ( See Appendix 1 )
MA2G CFG Editor
This tool allows parameters configuration. Use Ethernet link.
MA2G Downloader
This software is designated to update MorphoAccessTM firmware.
Page 25
SK-0000034370-01 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
25
AAPPPPEENNDDIIXX 33 -- DDRRIILLLLIINNGG TTEEMMPPLLAATTEE
Screw : 4 mm
Screw : 3 mm
Page 26
SAGEM Défense Sécurité
Siège social : Le Ponant de Paris
27, rue Leblanc - 75512 PARIS CEDEX 15 - FRANCE