Roland BN-20 User Manual

Page 1
WASTE LIQUID HANDLING
BN-20
Confi dential
Ver.1.0 December 5th, 2011
Page 2
The waste liquid can be discarded by either replacing the Waste Cartridge or only the Drain Pad inside the cartridge.
WASTE CARTRIDGE REPLACEMENT (Referential Time : 10min.)
Refer to the section titled “Replacing the Waste Cartridge” in the MASTER GUIDE of BN-20 to perform the following steps.
Parts NO: 1000007723 Parts Name: ASSY,DRAIN BN-20
1
OFF
Turn off the sub power SW and main power SW. Disconnect the USB Cable.
3
2
Waste Cartridge
Remove the Waste Cartridge.
Insert the new Waste Cartridge.
Waste Cartridge
- 2 -
Page 3
DRAIN PAD REPLACEMENT (Referential Time : 10min.)
Parts NO: 1000008938 Parts Name: ASSY,DRAIN PAD BN-20
1
Necessary Tools
Glove
2
Tweezers
OFF
Turn off the sub power SW and main power SW. Disconnect the USB Cable.
Remove the Waste Cartridge.
Waste Cartridge
34
Screw
Drain Tank Cover
Drain Pad
Screw
Remove the 4 screws which fi x the Drain Tank Cover.
Remove the current Drain Pad with the tweezers.
Wear a glove to prevent your hand from getting dirty.
- 3 -
Page 4
5
Drain Pad
T
F
[T] faces up.
[F] faces the front of the machine.
<Front Side>
Insert the new Drain Pad to the Drain Tank Case.
Drain Tank Case
Be careful about the insering direction of the Drain Pad.
67
Screw
Drain Tank Cover
Waste Cartridge
Screw
Fix the Drain Tank Cover with 4 screws.
Insert the Waste Cartridge.
- 4 -
Loading...