Operating Overview

For Model 34800 Enviro-Charge Dual Station

For all procedures shown, manifold and tank valves must be open.

This does not replace the instruction manual. Before operating the unit, read and understand the manual. Observe all warnings.

Recover - Automatic

Connect station hoses to A/C-R system.

Turn Main Power switch ON.

SHIFT

Press SHIFT/RESET

on keypad.

RESET

Press RECOVER RECOVER

on keypad.

Evacuate and Recycle - Automatic

Press SHIFT/RESET

SHIFT

on keypad.

 

 

 

RESET

 

Enter required evacuation time.

Press ENTER

ENTER

on keypad.

Press VACUUM

VACUUM

on keypad.

 

 

Recharge

SHIFT

Press SHIFT/RESET to display CHARGE and LBS. RESET

Enter amount of refrigerant to be charged.

Press ENTER

ENTER on keypad.

 

FILTER

 

Press CHG.

CHG.

on keypad.

 

 

RECYCLE FILTER

1

2

3

CHG.

 

 

 

4

5

6

CONT.HOLD

7

8

9

VACUUM

 

0

SHIFT

 

RECOVER

RESET

ENTER

Evacuate - Manual

Press SHIFT/RESET and ENTER

SHIFT

 

 

RESET

ENTER at the same time.

RECYCLE

Press RECYCLE. 1

Press SHIFT/RESET

SHIFT

to end.

 

 

RESET

 

Recycle - Manual

Press SHIFT/RESET and RECYCLE

SHIFT

 

RECYCLE

RESET

1 at the same time.

 

SHIFT

Press SHIFT/RESET to end.

RESET