34430 REPLACEMENT FILTER
WARNING
Always wear eye protection and protective
clothing when working with refrigerants. Contact with refrigerant may cause personal injury. Disconnect hoses and tubes with
To avoid possible hazardous release of refrigerant,
follow these steps carefully.
The 34430 Replacement Filter is for mobile applications only. If you have a microprocessor-controlled station, follow the directions in that station's operating manual to replace the filter. If your station does not have a microprocessor, follow these directions.
1. If recycling is in progress, turn off the RECYCLING switch. The compressor continues to operate until refriger­ant clears from the suction side of the A/C system.
2. Loosen the nuts at each end of the filter and remove the filter.
112615 (Rev. B 1/30/03) 34430 Replacement Filter © SPX Corporation
3. Install the new 34430 filter. The refrigerant flow arrow on the filter label must point to the left. The word “INLET” stamped on the end of the filter must be on the right.
4. When the filter is in place, evacuate the station for approximately 10 minutes to remove the air that entered during the filter changeout. Attach a vacuum pump to the oil drain port and open the oil drain valve. Start the vacuum pump and operate for the required amount of time.
The station is ready to resume operation.