Robinair 16451 User Manual

16451 Ultrasonic soUnd Generator
WARNING
Wear eye protection that meets the requirements of ANSI Z87.1 and OSHA.
The Robinair 16451 Ultrasonic Sound Generator and the Robinair 16455 “TruTrak” Ultrasonic Detector form a non-invasive leak detection system capable of
nding leaks in enclosures, such as buildings, vessels, automobiles, walk/reach-in freezers, or any other
container that needs to be leak-free.
The 16451 Sound Generator is used to “pressurize” rooms and enclosures with its sound. This sound is above the human hearing range and cannot be heard. It can penetrate through minute cracks, even ones that are not directly behind the leak point, and exit through it. It can thus trace the path air, or water, will take to cause a leak.
The 16455 Detector receives the ultrasonic sound that
escapes from the leak point, processes it, and displays its strength. The bigger the leak, the higher the volume
in the headset.
OPERATION
To test an enclosure:
1. Turn the 16451 sound generator ON. The low battery light will ash three times and then stay green, indicating a good battery. Place the sound generator on one side of the item to be tested.
BATTERY REPLACEMENT
The low battery light ashes red when it begins to fail. To replace the battery in the sound generator, turn the unit over, with its sensor output front toward you. The battery door is on the far side. To open, press down in the center of the back panel, and slide it away from you. It does not need much force to open. Replace with
one 9-volt battery.
APPLICATION SUGGESTIONS
Weatherizing buildings
Weatherizing buildings requires nding the points where the weather elements can enter the building. This task becomes very simple with the ultrasonic system.
1. Place the sound generator in a room to be leak­tested and turn the generator ON.
2. Go outside with the detector and start a systematic search to nd the leaks. Start around the perimeters of the doors and windows.
3. Use a tape and a marker pen to register the volume
levels at the locations they are discovered.
Note: Using tape saves having to repeat the checks.
4. After you have nished, read the numbers on your
tape and try to determine the cause of the problem.
This procedure can also be used to nd leaks in sealing logs in log homes or to check roong jobs.
2. Close the door, window, etc., or seal the enclosure being tested.
3. Using the 16455 detector, start with low sensitivity,
and listen for a sound.
a. If you can hear a sound, check the area of
interest, and note the points where the intensity is high.
b. If you cannot hear any sound, increase the
sensitivity and repeat the previous step. The
points where the sound is the greatest are most
likely leaks.
If the sound from the generator is too loud, and seems to be coming from everywhere, you should place the unit in a towel, or use another method to mufe the
sound.
BURST MODE
Pressing the MODE SELECT button changes the output to the generator from continuous tone to “Burst Tone.” If the background noise is extremely loud in a particular area, using Burst Tone will make the output of the sound generator easier to identify.
Automotive
Windshields and trunk seals can be tested by placing the sound generator on the inside of an automobile and testing on the outside. Verify area to be tested is dry, as the capillary tension in water may block the passage of
sound.
Refrigeration
Freezer boxes and refrigerated truck bodies can be tested for tightness like any other enclosure. Depending on the size, it may be necessary to move the sound generator every ten feet inside the trailer to maximize
its effectiveness.
CARE AND MAINTENANCE
The instrument may be wiped clean with a damp towel. Do not allow water to enter the unit, especially the front where the sensor is located. After cleaning, dry the unit with a paper towel. An automotive vinyl cleaner (on a piece of cloth) will restore the luster. If you plan to store the instrument for an extended period of time (1 year),
remove the battery.
SPECIFICATIONS
Frequency Control ............................. Precision Crystal Oscillator
Output Frequency ............................... 40 kHz (± 2.5 Hz)
Frequency Accuracy ...........................± 50 parts per million
Precision Voltage Regulator ............... 1% Regulation
Output Intensity ................................. 115 db at 300 cm (nominal)
Dual Mode Output ............................. Continuous or Burst Tone
Power ................................................. 9-volt Cell
Battery Life (approximately) ............. 70 hours continuous; 90 hours burst
For help in servicing your 16451 Ultrasonic Sound Generator,
call our toll-free Technical Support Line:
1-800-822-5561
in the co
In all other locations, call your local distributor.
ntinental U.S. and Canada.
To help us serve you better, please be prepared to provide the model number, serial number, and date of purchase of your unit.
NATIONWIDE NETWORK OF AUTHORIZED SERVICE CENTERS
If your unit needs replacement parts,contact the service center in your area. For help in locating a service center, call the toll-free technical support line or visit www.Robinair.com.
Due to ongoing product improvements,
we reserve the right to change design,
specications, and materials without notice.
655 Eisenhower Drive Owatonna, MN 55060 USA Technical Services: 1-800-822-5561 Fax: 1-866-259-1241 Customer Service: 1-800-533-6127 Fax: 1-800-322-2890 Web Site: www.robinair. com
525516 Rev. C April 4, 2014 © Bosch Automotive Service Solutions LLC
Loading...