FO26-1710/1000
S2 SENSOR / TRANSMITTER
— Available gases include
NH3 Sensor
Explosion Proof
LEL
Explosion Proof
O2 / CO / H2S
◦ LEL, H2S, CO, PPM H2, and CO2
◦ Toxic gases include NH3, AsH3,
Cl2, ClO2, HCN, & SO2
— Infrared sensor for combustibles
and CO2
— Hydrogen-Specific now available
— Patented water repellent sensor coating
— 4-20 mA output
— Explosion proof construction
— Optional stainless steel junction box
The RKI S2 series gas sensor/transmitters are highly reliable and very cost effective for the detection of common gas
hazards. The S2 series are available for LEL, H
gases. The transmitters for LEL, H2 Specific, Oxygen, H2S, CO2, and Carbon Monoxide are explosion-proof with flame
arrestors, and approved for use in hazardous areas (Class l, Div 1 Groups B, C, D). An optional non-explosion proof
version is available for oxygen, H2S, CO, and CO2 in non-hazardous atmospheres. LEL sensors are available using
catalytic bead and infrared technologies.
The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life.
The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in
Class I, Div. 2 hazardous locations. Sensors available for NH3, AsH3, Cl2, ClO2, HCN, PH3, and SO2.
The S2 transmitters can be used either indoors or outdoors. The flame arrestors for the explosion-proof versions
utilize a patented coating which make them water repellent. Splash guards are also available for use in very wet
environments. An optional stainless steel junction box is available for corrosive environments.
All of the S2 transmitters are designed to interface with RKI controllers, or with PLC/DCS systems.
World Leader In Gas Detection & Sensor Technology
RKI Instruments, Inc. | 33248 Central Ave. Union City, CA 94587 | Phone (800) 754-5165 | (510) 441-5656 | Fax (510) 441-5650
Specific (LEL, and ppm), Oxygen, H2S, CO, and for a variety of toxic
2
www.rkiinstruments.com

Explosion Proof
LEL
General
Purpose
Part #
65-2405RK 65-2451RK 65-2442RK-1000
65-2405RK-05 65-2451RK-05 65-2442RK-2000
Sensor
Measuring Range 0-100% LEL
Lower Detectable
Limit (LDL)
Accuracy
(whichever is
greater)
Response Time
Max Current Draw
(24VDC)
Expectancy
30 Seconds 20 Seconds 45 Seconds 90 Seconds 60 Seconds 90 Seconds 30 Seconds
(T-90)
70 mA (power wires) 25 mA (signal wires) 3 wires
2 to 3 years
with normal
Life
exposure to
flammable gas
Operating Environment
H2 Specific
Catalytic
0-100% LEL
(H2 Specific)
2% of full scale
± 5% of
reading or
± 2% LEL
3-5 years with
normal service
LEL
H2 PPM
Hydrogen
Metal oxide
semiconductor
0-1000 ppm
0-2000 ppm
± 10% of
reading or
± 5% of full scale
5 years plus with
normal service
O2
Oxygen
65-2322RK 65-2331RK 65-2336RK 65-2394RK-CH4 65-2394RK-HC
Galvanic cell Electrochemical Infrared
0-25% Vol. 0-100 ppm 0-300 ppm 0-100% LEL
0.1% Vol. 2% of full scale
± 0.5% O2
2-3 years with normal service 5 years plus with normal service
H2S
Hydrogen
Sulfide
± 5% of
reading
± 2 ppm H2S
25 mA max, 2 wires
CO
Carbon
Monoxide
± 5% of
reading
± 5 ppm CO
CH4
MethaneHCHydrocarbons
± 5% of
reading or
± 2% of full scale
60 mA (power wires)
25 mA (signal wires) 3 wires
CO2
Carbon
Dioxide
65-2396RK-02
65-2396RK-03
65-2396RK-05
65-2396RK-10
0 - 5000 ppm
0 - 5% Vol.
0 - 50% Vol.
0 - 100% Vol.
Location
Temperature
Humidity 0 - 99% RH, non condensing
-40°F to 167°F
-40°C to 75°C
Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.
-40°F to 167°F
-40°C to 75°C
-4°F to 113°F
-20°C to 45°C
-40°F to 104°F
-40°C to 40°C
23°F to 104°F
-5°C to 40°C
Housing
Housing J Box Cast aluminum explosion proof, optional stainless steel J-box available
Sensor Stainless steel explosion proof
Controls
Zero Sets transmitter output to 4 mA with zero output from sensor
Span Sets transmitter output to proper level when span gas is applied
Output
Operating
Voltage
Approvals
Controllers
11 VDC to 30 VDC
65-2405RKUL65-2451RK
65-2405RK-05
CSA
UL
65-2451RK-05
CSA
Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems
19 VDC to 30 VDC
UL CSA NRTL
4 - 20 mA signal
19-30VDC (250 OHMS
impedance max) 11 VDC to 30 VDC
-40°F to 122°F
-40°C to 50°C
UL
C
US
Warranty
www.rkiinstruments.com
One year materials and workmanship
S2 Sensor / Transmitter S2 Sensor / Transmitter(800) 754-5165