RISCO Group axesplus iREX User Manual

2. MOUNTING AND DETECTION
with the IQ feature
INSTALLATION INSTRUCTIONS
DESCRIPTION
1. INSTALLATION
iREX Components:
remotely enable or disable the iREX.
IMPORTANT:
The iREX should always be installed with the rounded side of the detector pointing to your left side when you are facing the iREX.
2
1
Wall Mounting 2.3m
Position 0
Ceiling Mounting 2.3m
Position 0
Wall Mounting 4.6m
Position 0
0
Front View
XXXX
Wall WallDoor
CC
4.7m
15.4ft
Top View
X
Ceiling Mounting 4.6m
Position 0
Adjusting Buzzer Volume:
Masking:
To insert a masking wedge:
To remove a masking wedge:
Masking Coverage:
Wall Mounting 2.3m
Position A
4.6m (15ft)
4m
(13.2ft)
3m
(9.9ft)
2m
(6.6ft)
1m
(3.3ft)
0m
(0ft)
Wall
Side View
1.2m
3.9ft
Wall Mounting 2.3m
Position B
A
Side View
Wall
2.3m
(7.5ft)
2m
(6.6ft)
Door
1m
(3.3ft)
B
NOTE:
Do not mount the detector in direct sunlight or near heated sources and metal objects.
0m (0ft)
2.4m
7.9ft
3. WIRING 4. DIP SWITCH OPTIONS
Switch Function Description
Terminal Application
"+" "-" Power Connection
"NC,C,NO" Contact Output Wiring
"R" Input Terminal Wiring
Parallel Door Control (iREX or iREX
Plus)
Use to control the door both from the iREX or from an external device (card reader, keypad) usually placed on the other side of the door.
(Dip Switch settings
on iREX Plus)
"D" Input Terminal Wiring *
"T" Tamper Switch Wiring *
NOTE:
* Available on iREX Plus only
UL NOTE:
Only UL Listed and/or Recognized wire suitable for the application shall be used and the minimum permissible wire size is No. 22 AWG (0.32mm2).
Connect to power supply between (+) and (-) terminal. (Voltage must be between 12-30 VAC or DC)
Basic Connection: Magnetic Lock Only
During motion detection, power is removed from the magnetic lock. The relay behaves according to the Fail Safe/Fail Secure definition.
Spike Protection
Add a diode or bridge rectifier for locks that are not spike protected.
Diode /
Bridge Rectifier
Remote iREX Disable (IQ feature) *
Use the Intelligent Queuing feature to remotely enable or disable the iREX from a remote device (such as a floor switch, additional PIR, Keycard, Burglar alarm system, etc.). The iREX will only activate by motion if the "R" terminal is open, or for 10 seconds after it closes. The iREX is
Remote Buzzer Control *
Use this wiring option to control the iREX buzzer from a remote contact. Buzzer is activated while R is open. Turning the buzzer on does not affect the relay.
disabled when the "R" input is closed after a delay of 10 seconds.
Door Alarm Mode *
If the door is forced open or left open for 10 seconds the buzzer turns on.
Door Secure Mode *
When the iREX is activated but the door remains closed, the relay will drop out after ten seconds. When the iREX is activated and the door is opened and then closed, the relay will drop out after 2 seconds.
_
Maglock
+
NC C NO NC C
Notes: Relay Timer Mode must be set for at least 16 seconds
The Door Alarm Mode is not to be considered as a UL listed Burglar Alarm System.
The tamper terminals are connected to the tamper switch, which opens when the cover is opened.
UL NOTE:
To comply with UL Standard 294, connect the tamper terminal to a 24 hour zone in your control panel.
Other Inputs
TTDR- +
NO
Wiring to an Access Control System
Note: It is recommended to set the
Relay Timer Activation to 1/2 second.
Wiring the Remote Buzzer Control to an Access Control System*
Output
Input
Access Controller
Door Contacts
(Normally Closed)
12 - 30 Volt
_
DC or AC
Power
+
Supply
TTDR
NC C NO NC C
+
-
12 - 30 Volt
_
DC or AC
Power
+
Supply
NO
1 LED
Operation
2 Timer Reset
Mode
ON (default) - LED is activated. The LED turns on when motion is detected. OFF - LED is disabled.
ON (default) - Relay timer resets when motion is detected during the Relay operation
time.
OFF - Relay timer does not reset when motion is detected during the Relay time.
3 Relay Mode
This switch defines the relay's operation when power is removed from the iREX. OFF (default) - Fail Secure mode. When power is removed from the iREX a locked door
will remain locked and secured against opening. (This mode should be authorized by your local authority)
ON - Fail Safe mode. When power is removed from the iREX a locked door will unlock and be safely opened.
(See Contact Output Wiring)
4, 5, 6 Relay Timer
Activation
(seconds)
SwitchRelay Timer
4 5 6
1/2 OFF OFF OFF
1 OFF OFF ON 2 OFF ON OFF
4(default)
OFF ON ON
8 ON OFF OFF 16 ON OFF ON 32 ON ON OFF
7 Signal
Processing
Determines the detector's PIR detection sensitivity to movement.
ON - High PIR sensitivity OFF (default) - Low PIR sensitivity.
8, 9, 10 Remote Input
Functions (See Wiring options)
Function
Switch
8 9 10 Parallel Door Control (default) OFF OFF OFF Remote Buzzer Control * OFF OFF ON Remote iREX Disable * OFF ON OFF Door Alarm Mode * OFF ON ON Door Secure Mode * ON ON ON
NOTE:
* Available on iREX Plus only
TECHNICAL SPECIFICATIONS For UL Standard 294 Compliance:
Power
Voltage 12-30 Volts DC or AC Current Consumption 8mA standby,
iREX: 30mA max (Relay+LED), iREX Plus: 50mA max at 12/24 VDC (including Buzzer)
Relay Output Rating 1A @ 30 volts DC or AC, two form
“C” contacts Tamper Output Rating 50mA @ 30 volts DC or AC Buzzer Output (iREX Plus) 85dB with adjustable volume Output Level at 10ft 69dBA
Detection System
Mounting Height 2.3m - 4.6m (7.5ft – 15ft) Detection range Width From 0.6m (2ft) up to 2.4m (7.9ft)
Physical
Dimensions (LxHxD) 177mm x 50mm x 45mm Weight 150g Color Black or White
Environmental
Radio Frequency Interference
30 V/m from 10 MHz to 2 GHz (RFI) Immunity
Operating Temperature -20°C to 55°C (-4°F to 131°F) Storage Temperature -20°C to 60°C (-4°F to 140°F) Humidity Up to 75%
Note: For indoor use only.
ORDERING INFORMATION
Model Description
iREX 700 iREX Request-to-Exit PIR White/Black iREX 700P iREX Plus Request-to-Exit PIR White/Black
1. RFI is not verified by UL
2. IQ remote feature is UL listed when it is controlled by Access Control units and not burglar alarm units.
3. NFPA 101 requires the use of Fail Safe relay mode. Fail Secure relay mode should be used where accepted under Local Authority jurisdiction.
4. Setting of low sensitivity at the mounting height of 15ft and 8.5ft may affect the maximum range.
5. Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.
6. If a fail-secure lock is employed, UL Listed panic hardware must be used to allow exit from the protected area.
7. All interconnected devices must be UL Listed.
8. Unit must be installed indoors within the protected premises.
9. The unit must be powered by a UL294 Listed Access Control, Power Limited, power supply capable of 4 hour standby.
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller can not guarantee the performance of the security system which uses this product. Sellers obligation and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, express ed or implied, and makes no warranty of merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Sellers obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay. Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona; injury or property loss by intruder, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of intruder, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result. Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise, regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty. WARNING: This product should be tested at least once a week.
Contacting RISCO Group
RISCO Group is committed to customer service and product support. You can contact us through our website (www.riscogroup.com) or at the following telephone and fax numbers:
United Kingdom
Tel: +44-161-655-5500 technical@riscogroup.co.uk
Italy
Tel: +39-02-66590054 support@riscogroup.it
Spain
Tel:+34-91-490-2133 support-es@riscogroup.com
France
Tel: +33-164-73-28-50 support-fr@riscogroup.com
All rights reserved. No part of this document may be reproduced in any form without prior written permission from the publisher. © RISCO Group 08/09 5IN700PR C
USA
Tel: +1-631-719-4400 support-usa@riscogroup.com
Belgium
Tel: +32-2522 7622 support-be@riscogroup.com
Brazil
Tel: +1-866-969-5111 support-br@riscogroup.com
China
Tel: +86-21-52-39-0066 support-cn@riscogroup.com
Poland
Tel: +48-22-500-28-40 support-pl@riscogroup.com
Israel
Tel: +972-3963-7777 support@riscogroup.com
Loading...