RIDGID AM2560 Owner's Manual

AM25600
THREE SPEED AIR MOVER
FOR QUESTIONS OR INFORMATION CONTACT US AT
1-800-4-RIDGID (1-800-474-3443) from the US and Canada
01-800-701-9811 from Mexico
www.ridgidvacs.com
OWNER’S MANUAL
SAVE THIS MANUAL FOR FUTURE REFERENCE
WARNING:
To reduce the risk of injury, the user must read and understand the owner’s manual before using this product.
!
Thank you for buying a RIDGID product.
• Español - página 11
• Français - page 21
2
Table of Contents
Section Page
Important Safety Instructions . . . . . . . .2
Motor Specifications and Electrical
Requirements . . . . . . . . . . . . . . . . .3
Introduction . . . . . . . . . . . . . . . . . . . . . .4
Unpacking and Checking Carton
Contents . . . . . . . . . . . . . . . . . . . . .4
Features and Operation . . . . . . . . . . . .5
Section Page
Storage and Transportation . . . . . . . . . . 6
Cleaning Your Air Mover . . . . . . . . . . . .7
User Servicing/Troubleshooting
Instructions . . . . . . . . . . . . . . . . . . .7
Repair Parts . . . . . . . . . . . . . . . . . . . .8-9
Wiring Diagram . . . . . . . . . . . . . . . . . . .9
Warranty . . . . . . . . . . . . . . . . . . . . . . . .10
IMPORTANT SAFETY INSTRUCTIONS
Safety is a combination of using common sense, staying alert, and knowing how your Air Mover works.
Safety Signal Words
DANGER: Indicates a hazardous
situation which, if not avoided,
will result
in death or serious injury.
WARNING: Indicates a hazardous
situation which, if not avoided,
could
result in death or serious injury.
CAUTION: Indicates a hazardous
situation which, if not avoided,
could
result in minor or moderate injury. When using your Air Mover, always follow
basic safety precautions including the following:
WARNING
- To reduce the risk of fire, electric shock, or injury:
• Read and understand this manual and all labels on the Air Mover before operating.
• Use only as described in this manual.
• To reduce the risk of electric shock, do not expose to rain, or immerse in or use in standing water. Store indoors only.
Use only with GFCI-protected outlets
.
Do not stac
k Air Mo
v
ers more than 2
units high.
• Do not use an extension cord with this Air Mover.
• Electrical appliances can ignite flammable vapors or dust.
Do not use near combustible liquids, gases, or dusts.
!
!
!
!
• Do not leave plugged into outlet when not in use or when servicing. Turn off before unplugging.
• To reduce the risk of stirring up and inhaling toxic vapors, do not use near toxic or hazardous materials.
• Never operate with safety grills removed.
• This unit has an automatically-operated protective device which may shut down the unit during operation. Unplug before servicing or cleaning.
• Do not use with solid state speed control device.
• Do not allow to be used as a toy. Close attention is necessary when used by or near children.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Do not use with damaged cord, plug, or other parts.
• If your Air Mover is not working as it should, has missing parts, has been dropped, damaged, left outdoors, or dropped into water, call customer service.
• Do not pull or carry by cord, use cord as handle
, close a door on cord, or pull
cord around shar
p edges or cor
ners
.
K
eep cord a
w
a
y from heated surfaces.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar co
v
erings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tr
ipped o
v
er
.
• Do not handle plug, switch, or the Air Mover with wet hands.
3
Motor Specifications and Electrical Requirements
READ AND SAVE THESE INSTRUCTIONS
This Air Mover is provided with a 3-speed, 115 volt, 60 Hz induction motor with a grounding conductor. It is thermally protected and will automatically shut down if over-heated. Once it cools, the motor will restart automatically if not unplugged.
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This Air
CAUTION:
• This fan has an automatic motor shutoff device; it may restart without notice. To reduce the risk of injury, unplug before servicing.
• Do not use an extension cord with this fan.
Do not lift Air Mover by retractable h
andle.
• Do not use retractable handle and wheels for going up and down stairs.
• Do not use unit as a hand truck or moving dolly.
• Do not put any object into air intake openings.
• Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
• Direct air discharge only at work area. Do not direct air at bystanders.
O
bserve the following warnings that
a
ppear on the motor housing of your Air
Mover:
CAUTION:
• For dusty operations, wear dust mask.
• Do not move or carry Air Mover when it is operating.
• Only operate on a level and stable surface to prevent it from falling and possibly causing injury or damage to unit.
!
WARNING: To reduce the risk of electric shock, connect only to a GFCI protected outlet. Do not expose to water or rain.
!
!
WARNING: TO REDUCE THE RISK OF TIP-OVER DURING STORAGE OR TRANSPORT, STACK 2-HIGH ONLY.
!
Mover is equipped with an electric cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided. If it will not fit the outlet, hav
e the proper outlet
installed by a qualified electrician.
Retractable Handle Locked
Retractable Handle Unlocked
Introduction
A
ir Movers are designed to move large volumes of air. They are used to dry wet carpets, floors and furniture. They may also be used for ventilation.
Unpacking and Checking Carton Contents
Carefully unpack and inspect your Air Mover. Call 1-800-4-RIDGID (1-800-474-3443) or E-mail us at info@ridgidvacs.com if any parts are damaged or missing.
Your Air Mover comes packaged with the retractable handle in a locked downward position.
4
Handle Down Position Handle Up Position
5
Features and Operation
Carrying Handle
Recessed Stacking Pads (4)
Air Outlet
Retractable Handle
Cord Wrap Area
3-Speed ON/OFF Switch
Wheels (2)
Foot Bumper (4)
Place Air Mover in desired operating position:
Floor & Carpet
90° Ceilings & Ventilation
NOTE: Collapse retractable handle for safety
.
6
W
hen stacking units, position the four foot
bumpers on the recessed stacking pads.
Recessed Stacking Pads (4)
Foot Bumper (4)
To transport the units in a stacked position, fully extend the bottom Air Mover handle. Grasp handles of each unit firmly, and tilt units backwards and move to desired location.
During Transportation, Firmly Grasp Both Handles
The units conveniently “stack” for storage, as shown
Storage and Transportation
CAUTION: Do not operate Air Mover when stacked on top of each other. Do not stack more than 2 high.
Air Mover Units Stacked 2 High Only
Air Mover Units Stacked 2 High Only
!
PREFERRED POSITION
ALTERNATE POSITION
7
User Servicing / Troubleshooting Instructions
Cleaning Your Air Mover
I
f the polypropylene housing becomes soiled it may be wiped off with a damp cloth.
WARNING: After servicing, any safety device (includes grilles, impeller, etc.) should be reinstalled or remounted.
PROBLEM CAUSE SOLUTION
Unit will not run. 1. No power to unit. 1. Plug unit in. Check circuit breaker.
2. Switch not on. 2. Place in “ON” position.
3. Switch is faulty. 3. Replace switch.
4. Faulty/broken cord or 4. Perform continuity check, using motor wire. volt/amp meter. Repair/replace
faulty broken wire.
Unit runs but air 1. Unit has been severely jolted 1. Remove motor and replace mover makes causing blower wheel to rub damaged motor or motor mounts, loud scraping against housing. as needed. noise. 2. Unit has been severely jolted 2. Replace blower wheel or damaged
causing housing to deform. housing.
Unit runs but 1. Severe jolt has bent motor 1. Remove and replace motor. vibrates shaft causing unit to be out of excessively. balance.
2. Blower wheel blade damaged. 2. Replace blower wheel if necessary.
3. Dirt build up on one side of 3. Clean blower wheel blades. Air Mover blower wheel.
Unit runs but 1. Blower wheel is jammed 1. Remove motor and replace blower wheel against housing. damaged motor mounts. Replace does not turn. blower wheel if necessary.
2. Capacitor wire has broken/ 2. Repair/replace wires/motor as come loose, capacitor has necessary. failed.
3. Housing has been damaged 3. Replace housing/unit as necessary. such that it presses on blower wheel.
Unit runs briefly, 1. Motor bearings are failing or 1. Replace motor. then shuts off motor has developed an on overload. internal electrical fault.
2. Intake grille and /or exhaust 2. Remove obstruction. grille is obstructed.
!
!
WARNING: Unplug before any disassembly or servicing.
Repair Parts
Three Speed Air Mover
Model Number AM25600
RIDGID parts are available on-line at www.ridgidparts.com
7
6
5
2
1
3
8
3
4
9
4
10
8
Repair Parts
Wiring Diagram
Three Speed Air Mover
Model Number AM25600
RIDGID parts are available on-line at www.ridgidparts.com
Always order by Part Number - Not by Key Number
RED (LOW)
BLUE (MED)
BLACK (HI)
MOTOR
GREEN
WHITE
SWITCH
POWER CORD
BLACK
Key
No. Part Number Description
1 510141 Switch & Knob
2 833658 Grille, Inlet
3 510140 Wheel Assembly
4 833690 Foot Bumper (4 pack)
5 833675 Cord w/Plug
6 833674 Motor
7 833659 Grille, Exhaust
8 833660 Blower Wheel
9 833691 Handle
10 SP6786 Owner’s Manual
9