Ricoh ic270 SPECIFICATIONS

Page 1
INTERCHANGE UNIT
(Machine Code: B300)
Page 2
20 September 1999 SPECIFICATIONS

1. OVERALL MACHINE INFORMATION

1.1 SPECIFICATIONS

Paper Size
Paper Weight: 52 g/m2 ~ 135 g/m2, 16 lb ~ 36 lb Power Consumption: 15 W Dimensions (W x D x H): 117 x 447 x 92 mm Weight: 1.6 kg
Standard sizes
A6 lengthwise to A3 HLT to DLT
Non-standard sizes
Width: 100 to 305 mm Length: 148 to 432 mm
B300-1
Options
Page 3
MECHANICAL COMPONENT LAYOUT 20 September 1999

1.2 MECHANICAL COMPONENT LAYOUT

2
3
4
1
8
5
7
6
B300V501.WMF
1. 1-bin Tray (Option)
2. Exit Sensor
3. Duplex Junction Gate
4. Duplex Unit (Option)
5. Exit Junction Gate
6. Fusing Unit (Inside the Copier)
7. Exit Roller
8. Bridge Unit
B300-2
Page 4
20 September 1999 DRIVE LAYOUT

1.3 DRIVE LAYOUT

2
3
1
B300V503.WMF
5
4
1. Exit Junction Gate Solenoid
2. Exit Sensor
3. Duplex Junction Gate Solenoid
B300V504.WMF
4. Exit Roller
5. Drive Gear
Options
B300-3
Page 5
JUNCTION GATE MECHANISM 20 September 1999

2. DETAILED DESCRIPTION

2.1 JUNCTION GATE MECHANISM

[C]
[A]
[D]
[B]
B300D504.WMF
[B]
[F]
[E]
[G]
B300D505.WMF
[A]
[A]
B300D506.WMF
Depending on the selected mode, the copies are directed up, left, or right by the exit junction gate [A] and the duplex junction gate [B]. These are controlled by the exit junction gate solenoid [C] and the duplex junction gate solenoid [D].
To the Exit Tray or Bridge Unit (for the Upper Tray on top of the Bridge Unit, or the Finisher)
The exit junction gate solenoid stays off and the paper is directed to the copier exit unit [E].
To the 1-bin Tray
The exit junction gate solenoid turns on and the duplex junction gate solenoid stays off. The paper is directed to the 1-bin tray [F].
To the Duplex Unit
The exit junction gate solenoid and the duplex junction gate solenoid both turn on and the paper is directed to the duplex unit [G].
B300-4
Page 6
20 September 1999 EXIT SENSOR REPLACEMENT

3. REPLACEMENT AND ADJUSTMENT

3.1 EXIT SENSOR REPLACEMENT

[A]
[B]
B300R501.WMF
1. Remove the interchange unit.
2. Remove the upper cover [A] of the interchange unit.
3. Remove the exit sensor [B] (1 connector).
Options
B300-5