INTERCHANGE UNIT
(Machine Code: B300/B416)

10 August, 2001 SPECIFICATIONS
1. OVERALL MACHINE INFORMATION
1.1 SPECIFICATIONS
Paper Size:
Paper Weight: 52 g/m2 ~ 135 g/m2, 16 lb ~ 36 lb
Power Consumption: 15 W
Dimensions (W x D x H): 117 x 447 x 92 mm
Weight: 1.6 kg
Standard sizes
A6 lengthwise to A3
HLT to DLT
Non-standard sizes
Width: 100 to 305 mm
Length: 148 to 432 mm
B416-1
Options

MECHANICAL COMPONENT LAYOUT 10 August, 2001
1.2 MECHANICAL COMPONENT LAYOUT
2
3
4
1
8
5
7
6
B416V501.WMF
1. 1-bin Tray (Option)
2. Exit Sensor
3. Duplex Junction Gate
4. Duplex Unit (Option)
5. Exit Junction Gate
6. Fusing Unit (Inside the Copier)
7. Exit Roller
8. Bridge Unit
B416-2

10 August, 2001 DRIVE LAYOUT
1.3 DRIVE LAYOUT
2
3
1
B416V503.WMF
5
4
1. Exit Junction Gate Solenoid
2. Exit Sensor
3. Duplex Junction Gate Solenoid
B416V504.WMF
4. Exit Roller
5. Drive Gear
Options
B416-3

JUNCTION GATE MECHANISM 10 August, 2001
2. DETAILED DESCRIPTION
2.1 JUNCTION GATE MECHANISM
[C]
[A]
[D]
[B]
B416D504.WMF
[B]
[F]
[E]
[G]
B416D505.WMF
[A]
[A]
B416D506.WMF
Depending on the selected mode, the copies are directed up, left, or right by the
exit junction gate [A] and the duplex junction gate [B]. These are controlled by the
exit junction gate solenoid [C] and the duplex junction gate solenoid [D].
To the Exit Tray or Bridge Unit (for the Upper Tray on top of the Bridge
Unit, or the Finisher)
The exit junction gate solenoid stays off and the paper is directed to the copier exit
unit [E].
To the 1-bin Tray
The exit junction gate solenoid turns on and the duplex junction gate solenoid stays
off. The paper is directed to the 1-bin tray [F].
To the Duplex Unit
The exit junction gate solenoid and the duplex junction gate solenoid both turn on
and the paper is directed to the duplex unit [G].
B416-4

10 August, 2001 EXIT SENSOR REPLACEMENT
3. REPLACEMENT AND ADJUSTMENT
3.1 EXIT SENSOR REPLACEMENT
[A]
[B]
B416R501.WMF
1. Remove the interchange unit.
2. Remove the upper cover [A] of the interchange unit.
3. Remove the exit sensor [B] (1 connector).
Options
B416-5