(1)TRADEBRAND IDENTIFICATION(7)AIRFLOW3 = Up to 3 tons(2)SERIES5 = Up to 5 tons98 % Efficient (8)CABINETWIDTH(3)MOTORTYPE14 = 14.0 inch V = ECM VariableSpeed17 = 17.5 inch 21 = 21.0 inch (4)MAJOR REVISION24 = 24.5 inch A = 1st Design Series B = 2nd Design Series(9)CONFIGURATIONU = UpFlow(5)HEATING INPUT DESIGNATION 040 = 42,000 BTU/HR (10)STANDARD/Nox 060 = 56,000 BTU/HR S = Standard 070 = 70,000 BTU/HR N = NOx 085 = 84,000 BTU/HR 100 = 98,000 BTU/HR (11)MINOR REVISION115 = 112,000 BTU/HRA = First Time Release
(6)MODULATING
SERIAL NUMBER EXPLANATION
W08139999
(1)(2)(3)(4)(1)PLANT CODE(2)WEEK(3)YEAR(4)PRODUCTION NUMBERNote: For Gas Code, see Control System Gas Code on Rating Plate
Page 3 of 21
24-September-2018
92-42800-R98V-USA
Page 4
MODEL
No. Notes
1Jacket AssemblySee Note 1
1aRoundFlush Mount Plug - 7/8 in. (6)45-103596-06 45-103596-06 45-103596-06 45-103596-06 45-103596-06
1bRectangularFlush Mount Plug - 1-27/32 x 2-1/2 in. (3)45-104315-01 45-104315-01 45-104315-01 45-104315-01 45-104315-01
1cRound Flush MountPlug - 2 in.45-103596-03 45-103596-03 45-103596-03 45-103596-03 45-103596-03
1dRoundFlush Mount Plug - 2-3/8 in.45-103596-04 45-103596-04 45-103596-04 45-103596-04 45-103596-04
1eRoundFlush Mount Plug - 3-7/16 in.45-103596-01 45-103596-01 45-103596-01 45-103596-01 45-103596-01
21DoorSwitch - Push ButtonSee Electrical Group
22Limit- Main Limit (Heat Exchanger Panel)See Electrical Group
23Limit- Manual Reset (Burner Compartment)See Electrical Group
24TransformerSee Electrical Group
25aInduced Draft Blower (IDB)See Electrical Group
29Wiring Harness Assembly (Twist-Lock)See Electrical Group
30Blower AssemblySee Blower Group
31aHousing w/Blower WheelSee Blower Group
40HeatExchanger AssemblySee Heat Exchanger/Burner/Manifold Group
41fO-Ring (fits overtapand seats on Collector Box)See Heat Exchanger/Burner/Manifold Group
42Burner AssemblySee Heat Exchanger/Burner/Manifold Group
47Manifold (w/o Orifices)See Heat Exchanger/Burner/Manifold Group
50GasValveSee Gas Controls
51Integrated Furnace Control Board (IFC)See Gas Controls
Stk
33ECM Motor Mount (Belly Band)70-19927-0470-19927-0470-19927-0470-19927-0470-19927-04
34Motor Mount Arm (4)70-19929-1070-19929-1070-19929-1070-19929-1070-19929-10
35Screw - Motor Mount Arm (4)63-101978-01 63-101978-01 63-101978-01 63-101978-01 63-101978-01
INPUT
AIRFLOW
CABINETWIDTH
CONFIGURATION
ELECTRIC GROUP
MODEL
INPUT
AIRFLOW
CABINETWIDTH
CONFIGURATION
BLOWER GROUP
Belly Band Motor Mount Kit(includes Motor Mount Arms, Belly Band
and Mounting Hardware)
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for thespecific installation:
1) Altitude in of the installation (ft.).
2) Average sea level energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LPConversion Kit Index 92-21519-71 and the latest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas andPropane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposesand altitude adjustment of rates other than 0 - 2000 feet only.
NOTE:This Orifice sizing chart is based on 14,000 BTU/HR per burner atsea level and conforms to a2% degradaton per thousand feet in elevation.
NOTE: Factory installed orifices are calculated and sizedbased on a Natural Gas heating valueof 1100 BTU/cu. ft. and an elevationof 0 - 2000 ft.
Elevation (ft.)
CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LPConversion Kit Index 92-21519-71 and the latest edition of the
National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gasand Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposesonly. Conversion to LP or foroperation at High Altitude should be done using the
kit(s) specified on the product specification sheet for theunit.
NOTE:This Orifice sizing chart is based on 14,000 BTU/HR per burner. Also, thechart is developed using the specified pressuresetting of 10 in. water column
instead of the 11.0 inwater column used by the NFG and CANB149.1.
NOTE: Orifices supplied inthe LP Conversion Kit are calculated andsized based on an altitude of 0 - 2000ft.
Elevation (ft.)
0 to 2000 ft.1400062-22175-90
2001 to 30001344062-22175-90
3001 to 40001316062-22175-90
4001 to 50001288062-22175-90
5001 to 60001260062-22175-90
6001 to 70001232062-22175-90
7001 to 80001204062-22175-90
97/98% GAS FURNACE - ORIFICE SELECTION CHART - NATURAL GAS
97/98% GAS FURNACE - ORIFICE SELECTION CHART - LP
Orifice
(1.10mm)
Page 9 of 21
24-September-2018
92-42800-R98V-USA
Page 10
Exploded View
Page 10 of 21
24-September-2018
92-42800-R98V-USA
Page 11
Cabinet Insulation and Plugs
Page 11 of 21
24-September-2018
92-42800-R98V-USA
Page 12
Junction Box
Page 12 of 21
24-September-2018
92-42800-R98V-USA
Page 13
Burner-Assembly
Flame Sensor-Limits
Page 13 of 21
24-September-2018
92-42800-R98V-USA
Page 14
Pressure Switch -Tubing
Burner-Gas Valve
Page 14 of 21
24-September-2018
92-42800-R98V-USA
Page 15
Trap - Hose Assembly
Page 15 of 21
24-September-2018
92-42800-R98V-USA
Page 16
Blower Shelf
Page 16 of 21
24-September-2018
92-42800-R98V-USA
Page 17
Blower Asssembly
Page 17 of 21
24-September-2018
92-42800-R98V-USA
Page 18
Control Board Mounting
Page 18 of 21
24-September-2018
92-42800-R98V-USA
Page 19
Heat Exchanger - Collector Box
Page 19 of 21
24-September-2018
92-42800-R98V-USA
Page 20
Parts Bag
Page 20 of 21
24-September-2018
92-42800-R98V-USA
Page 21
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Jacket is not available for replacement.
2 Order GasValve forNatural Gas along with LP Conversion Kit.
3 Order SiliconTubing, 791004 (36 in. length), and cut as needed for individual tubing lengths.
DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified
service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair
should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject
to change without notice. Document 92-42800-R98V-USA supersedes all previous parts lists for these models.
See http://www.rheempartslists.net/92-42800-R98V-USA for the latest revision of this document. The
manufacturer assumes no obligation for errors or omissions. Service personnel must verify the proper and safe
operation of equipment after the replacement of any original components.