Rheem R96P Specification

Rheem Classic Plus™Series Two Stage Multi position Gas Furnaces
FORM NO. G11-539 REV. 3
R96P- Series
96% A.F.U.E.†* Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW]
• Up to 96% residential gas furnace CSA certified
4 way multi-poise design
Two stages of operation to save energy and maintain optimal
comfort level.
PlusOne
Diagnostics 7-Segment LED all units
PlusOne
Ignition System – DSI for reliability and longevity
PlusOne
Water Management System with patented Blocked
Drain Sensor
Heat exchanger is removable for improved serviceability.
Aluminized steel primary and stainless steel secondary con­struction provide maximum corrosion resistance and thermal fatigue reliability.
Low profile “34 inch” cabinet ideal for space constrained
installations.
Blower Shelf design – serviceable in all furnace orientations
Pre marked hoses – insures proper system drainage
Vent with 2" or 3" PVC
Replaceable Collector box
Hemmed edges on cabinet and doors
Quarter turn fasteners for tool less access
Integrated control boards feature dip switches for easy
system set up
Self priming condensate trap
Solid bottom included
Air
Gas Furnaces
R96P Series
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
*Up to 96% A.F.U.E.
Air
Table of Contents
R96P Series
2
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Physical Data & Specifications ........................................................................4
Model Number Identification ............................................................................5
Dimensional Data............................................................................................6
Blower Performance Data ................................................................................7
Accessories....................................................................................................8
Limited Warranty ............................................................................................9
Air
Standard & Optional Equipment
R96P Series
3
STANDARD EQUIPMENT
Completely assembled and wired; blocked drain sensor, 7 segment LED and marked hoses; heat exchanger; primary: aluminized steel, secondary: 29-4C stainless steel; 2 stage induced draft; pressure switches; redundant 2 stage main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self­test diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applica­tions; transformer; direct drive, multi-speed blower motor. Solid bottom. (Please note: a thermostat is not included as standard equipment.)
OPTIONAL EQUIPMENT
Side and bottom filter racks; return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural
or L.P. (propane) gas.
All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burn­ers. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
PRIMARY AND SECONDARY HEAT EXCHANGER
IN-SHOT BURNERS
PRESSURE SWITCHES
DRAFT INDUCER
CONTROL
BOARD
GAS VALVE AND MANIFOLD
DIRECT SPARK IGNITION & REMOTE SENSOR
REMOTE SENSOR
BLOCKED DRAIN SENSOR
Air
Physical Data & Specifications
R96P Series
4
Physical Data and Specifications—Upflow Models
U.S. and Canadian Models
MODEL NUMBERS R96PA0402317MSA R96PA0602317MSA R96PA0702317MSA R96P0852521MSA R96PA1002521MSA R96PA1152524MSA
HIGH FIRE INPUT BTU/HR [kW]
42,000 [12.31] 56,000 [16.41] 70,000 [20.50] 84,000 [24.61] 98,000 [38.71] 112,000 [32.82] LOW FIRE INPUT BTU/HR [kW] 29,400 [8.61] 39,200 [11.49] 49,000 [14.36] 58,800 [17.23] 68,600 [20.11] 78,400 [22.97] HEATING CAPACITY BTU/HR [kW] 40,320 [11.82] 53,760 [15.75] 67,200 [19.68] 80,640 [23.63] 94,080 [37.16] 107,520 [31.51] HIGH ALTITUDE OUTPUT
10% DERATE [kW]
36,288 [10.64] 48,384 [14.18] 60,480 [17.72] 72,576 [21.28] 84,672 [24.81] 96,768 [28.36]
BLOWER (D x W) [mm]
11 x 7
[279 x 178]
11 x 8
[279 x 203]
11 x 8
[279 x 203]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 11
[279 x 279]
MOTOR H.P. [W]– TYPE
1/4 [187]-4-PSC 1/2 [373]-4-PSC 1/2 [373]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC
MOTOR FULL LOAD AMPS 4.0 6.8 6.8 8.3 8.3 8.3 HEATING SPEED MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH MINIMUM EXT. STATIC
PRESSURE (IN. W.C.) [kPa]
.18 [.045] .20 [.050] .23 [.057] .28 [.070] .28 [.070] .28 [.070]
MAXIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa]
0.8 [0.19] 0.8 [0.19] 0.8 [0.19] 0.8 [0.19] 0.8 [0.19] 0.8 [0.19]
HEATING CFM @ .2" [.049 kPa] W.C. E.S.P. [L/s]
1049 [494] 1139 [537] 1211 [571] 1704 [804] 1748 [825] 1750 [825]
COOLING CFM @ .5" [.124 kPa] W.C. E.S.P. [L/s]
1121 [528] 1232 [581] 1318 [622] 1742 [822] 1782 [841] 1934 [912]
TEMPERATURE RISE-HIGH FIRE RANGE IN DEGREES °F [°C]
20 - 50
[11 -28]
30 - 60
[17 - 33]
40 - 70
[22 - 39]
30 - 60
[17 - 33]
40 - 70
[22 - 39]
45 - 75
[25 - 42]
TEMPERATURE RISE-LOW FIRE RANGE IN DEGREES °F [°C]
15 - 45 [8 -25]
20 - 50
[11 - 28]
30 - 60
[17 - 33]
20 - 50
[11 - 28]
30 - 60
[17 - 33]
35 - 65
[19 - 36]
APPROX. SHIPPING WEIGHT (LBS.) [kg]
123.5 [56] 128 [58] 132 [60] 147.5 [67] 152 [69] 165 [75]
AFUE
96.00% 96.00% 96.00% 95.00% 95.00% 96.00%
NOTES: All models are 115V, 60HZ, 1 phase Gas connection size for all models is 1/2" [13 mm] N.P.T.
Installation instructions for high altitude derate.Canadian installations only.In accordance with D.O.E. test procedures.
*S=Standard Models
NOTE: Standard model complies with California low nox requirements.
[ ] Designates Metric Conversions