Rheem R801T DF, R801T Series Series Manual

Page 1
Rheem Classic Plus™Series
Downflow Gas Furnace
FORM NO. G11-549
80% residential Gas Furnace CSA certified
Diagnostics — 7 Segment LED all units
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
Low profile 34" cabinet ideal for space constrained installations
Integrated Control board features dip switches for easy system set up
QR code for quick access to product information from your smart phone or tablet
Constant Torque electrically commutated motor
Air
Gas Furnaces
R801T (DF) Series
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
R801T Downflow Series
80% A.F.U.E.† Input Rates 75-125 kBTU
Page 2
Air
Table of Contents
R801T (DF) Series
2
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Model Features/Physical Data & Specifications..................................................4
Model Number Identification ............................................................................5
Dimensional Data............................................................................................6
Blower Performance Data ................................................................................7
Accessories....................................................................................................8
Limited Warranty ............................................................................................9
Page 3
HEAT EXCHANGER
INTEGRATED FURNACE CONTROL
DIRECT SPARK IGNITOR
WITH REMOTE SENSE
IN-SHOT BURNERS
DRAFT INDUCER MOTOR
Air
Standard & Optional Equipment
R801T (DF) Series
3
STANDARD EQUIPMENT
Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; on-board twinning; fused-protection (secondary), 3rd speed option for
continuous fan; common heat/cool terminal.
OPTIONAL EQUIPMENT
NOTE: Furnace is not listed for use with fuels other than
natural or L.P. (propane) gas.
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark
ignition is 100% lockout type.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
CONSTANT TORQUE ECM MOTOR
Page 4
MODEL NUMBERS R801T (DF) SERIES
R801TA075317Z*A R801TA075521Z*A
Input in BTU’s/Hr [kW]
75,000
[22]
75,000
[22]
Heating Capacity in BTU’s/Hr [kW]
60,000
[18]
60,000
[18]
High Altitude Input in BTU’s/Hr [kW]*
67,500
[20]
67,500
[20]
Blower (D x W) in inches [mm]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
Motor H.P.-Speeds ­Type [W]
1/2hp, 5spd,
X-13 [373]
1hp, 5spd,
X-13 [746] Motor Full Load Amps 6.8 10.9 Heating Speed (factory setting) MED-HIGH MED Cooling Speed (factory setting) HIGH HIGH Cooling in CFM [L/s] @ 0.5"wc
[0.12 kPa] E.S.P. (nominal)
1200
[566]
2000 [944]
Rated E.S.P. in "wc [kPa]
0.5
[0.12]
0.5
[0.12]
Temperature Rise Range in °F [°C]
30-60
[17-33]
25-55
[13.9-30.6]
Max Outlet Air in °F [°C]
165
[73.8]
165
[73.8]
Approx. Shipping Weight in Lbs. [kg]
105 [48]
120 [54]
High Altitude Output Capacity in BTU’s/Hr [kW]*
53,500
[16]
53,500
[16]
Heat Ext. Static Pressure in "wc [kPa]
0.12
[0.029]
0.12
[0.029]
R801TA100521Z*A R801TA125524Z*A
100,000
[29]
125,000
[37]
72,500
[21]
89,000
[26.1]
81,000
[24]
99,000
[29]
0.15
[0.037]
0.2
[0.05]
90,000
[26]
112,500
[33]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
1hp, 5spd, X-13 [746]
1hp, 5spd, X-13 [746]
10.9 10.9
MED-HIGH MED-HIGH
HIGH HIGH 2000
[944]
2000 [944]
0.5
[0.12]
0.5
[0.12]
30-60
[17-33]
35-65
[19.4-36.1]
190
[87.7]
185
[85.0]
120 [54]
140 [63]
80.0% 80.0%
AFUE - Electronic Ignition Modules
80.0% 80.0%
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" N.P.T.
In accordance with D.O.E. test procedures.See Conversion Kit Index Form for high altitude derate in U.S. applications.
[ ] Designates Metric Conversions
Air
Model Features/Physical Data & Specifications
R801T (DF) Series
4
Physical Data and Specifications
U.S. and Canadian Models
80% residential Gas Furnace CSA certified
Diagnostics — 7 Segment LED all units
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
Low profile 34" cabinet ideal for space constrained installations
Integrated Controls board features dip switches for easy system set up
QR code for quick access to product information from your smart phone or tablet
Constant Torque electrically commutated motor
Model Features
Page 5
Air
Model Number Identification
R801T (DF) Series
5
Model Number Identification—Downflow Models
R 80 1 T A 075 4 17 Z S A
Rheem 80 =
80% AFUE
1 = Single Stage T =
Constant
Torque
Design Series
A = 1st Design
Input
BTU/HR [kW]
075 = 75,000 [22] 100 = 100,000 [29] 125 = 125,000 [37]
3 = Up to
3 Ton
4 = 21/2 to
4 Ton
5 = 31/2 to
5 Ton
Cabinet
Width 17 = 17.5" 21 = 21".0 24 = 24.5"
Z = Down
and Zero Clearance Downflow
X = Low NOx S = Standard
Revision­Marketing
(A – First Time
Release)
[ ] Designates Metric Conversions
Page 6
Air
Dimensional Data
R801T (DF) Series
6
Downflow Dimensions
A
REDUCED CLEARANCES (IN.) [mm]
LEFT SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
SHIP. WGTS.
(LBS.) [kg]
075317 171/2 [445] 1611/32 [415] 121/8 [308]
165/8 [422] 0
3
0 1 [25] 3 [76]
6 [152]
105 [47.6]
075521 21 [533] 1927/32 [504] 137/8 [352]
201/8 [511] 0
0
0 1 [25] 3 [76]
6 [152]
120 [54.4]
100 21 [533] 1927/32 [504] 137/8 [352]
201/8 [511] 0
0
0 1 [25] 3 [76]
6 [152]
120 [54.4]
125 241/2 [622] 2311/32 [593] 155/8 [397]
235/8 [600] 0 0 0 1 [25] 3 [76]
6 [152]
140 [63.5]
MODEL
R801T
(DOWNFLOW)
SERIES
B C D E
Dimensional Data
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes.
[ ] Designates Metric Conversions
Page 7
AIR FLOW PERFORMANCE - (-)801T SERIES (Downflow) MODELS
MODEL
MOTOR H.P. [W]
BLOWER SIZE
IN [mm]
SPEED
TAP
CFM [L/s] AIR DELIVERY
EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa]
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.5 [.12] 0.6 [.15] 0.8 [.19]
(-)801TA075317ZSA
1/2 [373]
11 x 7
[279 x 178]
Low
Med. Lo
Med
Med. Hi
High
916 993
1205
1367
1475
803 952
1158
1333
1444
669 910
1124
1300
1416
561 827
1056
1236
1354
504 793
1024
1203
1329
421 706 950
1140
1264
(-)801TA075521ZSA
1 [748] 11 x 10
[279 x 254]
Low
Med. Lo
Med
Med. Hi
High
1198 1411
1608
1918 2122
1105 1358
1564
1877 2083
1093 1317
1529
1840 2054
931
1227
1451
1767 1977
901
1196
1416
1706 1945
791
1093
1340
1636 1874
(-)801TA100521ZSA
1 [748] 11 x 10
[279 x 254]
Low
Med. Lo
Med
Med. Hi
High
1240 1405 1600
1903
2072
1120 1364 1561
1877
2028
1073 1317 1526
1833
2006
974 1232 1445
1766
1940
917 1181 1403
1711
1908
799 1083 1325
1631
1840
(-)801TA125524ZSA
1 [748] 11 x 10
[279 x 254]
Low
Med. Lo
Med
Med. Hi
High
1225 1302 1553
1902
2403
1073 1240 1503
1859
2369
988 1191 1455
1822
2332
864 1074 1370
1722
2246
795 1027 1313
1686
2190
697 932
1237
1602
2059
NOTE: Bold data is factory heating tap
[ ] Designates Metric Conversions
Air
Blower Performance Data
R801T (DF) Series
7
Blower Performance Data—Downflow Models
Page 8
Air
Accessories
R801T (DF) Series
8
DOWNFLOW ACCESSORIES
DOWNFLOW WARNING: Unit design is certified for installation on non­combustible floor. A special factory supplied combustible floor sub­base is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage and personal injury.
RXGF-CC*
FILTER RACK—Downflow top return mount. Requires (2) 14 x 20 Filters.
NOTE: Filter racks are shipped without filters.
*Filters available through PROSTOCK
®
.
FOR HIGH ALTITUDES:
HIGH ALTITUDE OPTION CODE: U.S. & Canada –
None required for high altitudes. HIGH ALTITUDE CONVERSION KITS: U.S. & Canada –
None required for high altitudes.
80+ HIGH ALTITUDE INSTRUCTIONS
Caution: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes.
High altitude option codes are not required for these models. However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information.
NOTE: For Canadian installations only, an optional derate (manifold gas
pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations.
COMBUSTIBLE FLOOR BASE DIMENSIONS
COMBUSTIBLE
FLOOR BASE
USE WITH
FURNACE SIZES
A
IN. [mm]BIN. [mm]CIN. [mm]
RXGC-B17 R801T075317 18 [457] 163/4 [425] 143/4 [451] RXGC-B21 R801T100521, R801T075521 211/2 [546] 201/4 [514] 181/4 [464] RXGC-B24 R801T125 25 [635] 233/4 [603] 213/4 [552]
[ ] Designates Metric Conversions
Page 9
Air
Limited Warranty
R801T (DF) Series
9
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties,
including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Heat Exchanger........................................Twenty (20 Years
Conditional Parts (Registration Required) ........Ten (10) Years
Page 10
Air
Notes
R801T (DF) Series
10
Page 11
Air
Notes
R801T (DF) Series
11
Page 12
The new degree of comfort.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A 7/14 QG FORM NO. G11-549
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5