Rheem R801T DF, R801T Series Series Manual

Rheem Classic Plus™Series
Downflow Gas Furnace
FORM NO. G11-549
80% residential Gas Furnace CSA certified
Diagnostics — 7 Segment LED all units
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
Low profile 34" cabinet ideal for space constrained installations
Integrated Control board features dip switches for easy system set up
QR code for quick access to product information from your smart phone or tablet
Constant Torque electrically commutated motor
Air
Gas Furnaces
R801T (DF) Series
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
R801T Downflow Series
80% A.F.U.E.† Input Rates 75-125 kBTU
Air
Table of Contents
R801T (DF) Series
2
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Model Features/Physical Data & Specifications..................................................4
Model Number Identification ............................................................................5
Dimensional Data............................................................................................6
Blower Performance Data ................................................................................7
Accessories....................................................................................................8
Limited Warranty ............................................................................................9
HEAT EXCHANGER
INTEGRATED FURNACE CONTROL
DIRECT SPARK IGNITOR
WITH REMOTE SENSE
IN-SHOT BURNERS
DRAFT INDUCER MOTOR
Air
Standard & Optional Equipment
R801T (DF) Series
3
STANDARD EQUIPMENT
Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; on-board twinning; fused-protection (secondary), 3rd speed option for
continuous fan; common heat/cool terminal.
OPTIONAL EQUIPMENT
NOTE: Furnace is not listed for use with fuels other than
natural or L.P. (propane) gas.
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark
ignition is 100% lockout type.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
CONSTANT TORQUE ECM MOTOR
MODEL NUMBERS R801T (DF) SERIES
R801TA075317Z*A R801TA075521Z*A
Input in BTU’s/Hr [kW]
75,000
[22]
75,000
[22]
Heating Capacity in BTU’s/Hr [kW]
60,000
[18]
60,000
[18]
High Altitude Input in BTU’s/Hr [kW]*
67,500
[20]
67,500
[20]
Blower (D x W) in inches [mm]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
Motor H.P.-Speeds ­Type [W]
1/2hp, 5spd,
X-13 [373]
1hp, 5spd,
X-13 [746] Motor Full Load Amps 6.8 10.9 Heating Speed (factory setting) MED-HIGH MED Cooling Speed (factory setting) HIGH HIGH Cooling in CFM [L/s] @ 0.5"wc
[0.12 kPa] E.S.P. (nominal)
1200
[566]
2000 [944]
Rated E.S.P. in "wc [kPa]
0.5
[0.12]
0.5
[0.12]
Temperature Rise Range in °F [°C]
30-60
[17-33]
25-55
[13.9-30.6]
Max Outlet Air in °F [°C]
165
[73.8]
165
[73.8]
Approx. Shipping Weight in Lbs. [kg]
105 [48]
120 [54]
High Altitude Output Capacity in BTU’s/Hr [kW]*
53,500
[16]
53,500
[16]
Heat Ext. Static Pressure in "wc [kPa]
0.12
[0.029]
0.12
[0.029]
R801TA100521Z*A R801TA125524Z*A
100,000
[29]
125,000
[37]
72,500
[21]
89,000
[26.1]
81,000
[24]
99,000
[29]
0.15
[0.037]
0.2
[0.05]
90,000
[26]
112,500
[33]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
1hp, 5spd, X-13 [746]
1hp, 5spd, X-13 [746]
10.9 10.9
MED-HIGH MED-HIGH
HIGH HIGH 2000
[944]
2000 [944]
0.5
[0.12]
0.5
[0.12]
30-60
[17-33]
35-65
[19.4-36.1]
190
[87.7]
185
[85.0]
120 [54]
140 [63]
80.0% 80.0%
AFUE - Electronic Ignition Modules
80.0% 80.0%
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" N.P.T.
In accordance with D.O.E. test procedures.See Conversion Kit Index Form for high altitude derate in U.S. applications.
[ ] Designates Metric Conversions
Air
Model Features/Physical Data & Specifications
R801T (DF) Series
4
Physical Data and Specifications
U.S. and Canadian Models
80% residential Gas Furnace CSA certified
Diagnostics — 7 Segment LED all units
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
Low profile 34" cabinet ideal for space constrained installations
Integrated Controls board features dip switches for easy system set up
QR code for quick access to product information from your smart phone or tablet
Constant Torque electrically commutated motor
Model Features
Loading...