(1)TRADEBRAND IDENTIFICATION(7)AIRFLOW3 = Up to 3 tons(2)SERIES4 = Up to 4 tons80% Efficient5 = Up to 5 tons
(3)STAGE - SINGLE (1)(8)CABINETWIDTH14 = 14.0 inch (4)MOTORTYPE17 = 17.5 inch S = Motor - PSC Standard21 = 21.0 inch 24 = 24.5 inch (5)MAJOR REVISIONA = 1st Design Series (9)CONFIGURATIONM = Up Flow/Horizontal(6)HEATING INPUT DESIGNATION 050 = 50,000 BTU/HR (10)STANDARD/Nox 075 = 75,000 BTU/HR S = Standard 100 = 98,000 BTU/HR X = NOx 125 = 125,000 BTU/HR150 = 150,000 BTU/HR(11)MINOR REVISIONA = First Time Release
SERIAL NUMBER EXPLANATION
W08149999
(1)(2)(3)(4)(1)PLANT CODE(2)WEEK (DATE CODE)(3)YEAR(4)PRODUCTION NUMBERNote: For Gas Code, see Control System Gas Code on Rating Plate
Page 3 of 16
92-42801-R801S-MSA,MXA
24-July-2018
MODEL
INPUT
Note
No.
1Jacket AssemblySee Note 1
1a Star Bushing45-18515-01 45-18515-01 45-18515-01 45-18515-01 45-18515-01 45-18515-01 45-18515-01
1b Insulation - Foil Back68-104821-05 68-104821-06 68-104821-06 68-104821-06 68-104821-07 68-104821-08 68-104821-08
1c Insulation - SoundN/AN/AN/AN/AN/AN/AN/A
1d Insulation Retainer (2)N/AN/AN/AN/AN/AN/AN/A
2a Top Plate Assembly (includes air deflector) AS-104767-01 AS-104767-02 AS-104767-02 AS-104767-02 AS-104767-03 AS-104767-04 AS-104767-04
2b Intake Air Deflector (attached to top plate) AE-101077-02 AE-101077-01 AE-101077-01 AE-101077-01 AE-101077-01 AE-101077-01 AE-101077-01
2c Left JacketBaffleAE-61606-01 AE-61606-01N/AAE-61606-01 AE-61668-01 AE-61665-01N/A
2d Right Jacket BaffleAE-61606-01 AE-61606-01N/AAE-61606-01 AE-61668-01 AE-61665-01N/A
2e Rear Jacket BaffleAE-61666-01 AE-61607-01 AE-61607-01 AE-61607-01 AE-61667-01 AE-61670-01 AE-61669-01
2fHeat Exchanger Bracket - Left SideSee Heat Exchanger/Burner/Manifold Group
2g Heat Exchanger Bracket - Right SideSee Heat Exchanger/Burner/Manifold Group
3Burner Compartment Door - Upper Door AS-104042-14 AS-104042-11 AS-104042-11 AS-104042-11 AS-104042-12 AS-104042-13 AS-104042-13
20b Silicon Tubing - Pressure SwitchSee Electrical Group
21 Door Switch - Push ButtonSee Electrical Group
22 Limit - Main Limit (Heat Exchanger Panel)See Electrical Group
23
24 TransformerSee Electrical Group
25 Induced Draft Blower (IDB)See Electrical Group
27 Capacitor - Blower MotorSee Electrical Group
28 Strap - Blower Motor CapacitorSee Electrical Group
29
30 Blower AssemblySee Blower Group
30a Control Mounting PlateSee Blower Group
31a Housing w/Blower WheelSee Blower Group
31b Blower WheelSee Blower Group
40 Heat Exchanger AssemblySee Heat Exchanger/Burner/Manifold Group
42 Burner AssemblySee Heat Exchanger/Burner/Manifold Group
43 Manifold (w/o Orifices)See Heat Exchanger/Burner/Manifold Group
50 Gas ValveSee Gas Controls
51 Integrated Furnace Control Board (IFC)See Gas Controls
52 Flame SensorSee Gas Controls
53 Spark IgnitorSee Gas Controls
AIRFLOW
s
CABINETWIDTH
CONFIGURATION
Door Filler (with integral molded alignment
pins)
Door Latch Kit (includes two of each:
Latch Cam, Latch Handle, O-Ring,
Retainer Screw)
32 Stk Blower Motor51-104939-01 51-104940-03 51-104940-01 51-104940-01 51-104940-02 51-104941-01 51-104941-02
27 Capacitor - Blower MotorSee Electric Group
33 ECM Motor Mount (Belly Band)70-19927-04 70-19927-04 70-19927-04 70-19927-04 70-19927-04 70-19927-04 70-19927-04
34 Motor Mount Arm (4)70-19929-10 70-19929-10 70-19929-10 70-19929-10 70-19929-10 70-19929-10 70-19929-10
35 Screw - Motor Mount Arm (4)63-101978-01 63-101978-01 63-101978-01 63-101978-01 63-101978-01 63-101978-01 63-101978-01
AIRFLOW
s
CABINETWIDTH
CONFIGURATION
Limit - Manual Reset (Burner
Compartment)
Bracket (Limit - Manual Reset)See Heat Exchanger/Burner Manifold Group
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Altitude in of the installation (ft.).
2) Average energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-70 and the latest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified
on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner.
NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 3000 ft.
Elevation (ft.)
CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-70 and the latest edition of the
National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the
kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner. Also, the chart is developed using the specified pressure setting of 10 in. water column
instead of the 11.0 in water column used by the NFG and CANB149.1.
NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on an altitude of 0 - 4000 ft.