REMKO ATR-1 User Manual

REMKO ATR 1 + 2
Day/Night
Temperature Control
Edition GB - P06
Operation Technology
Original REMKO
REMKO - powerful like a bear
Description of Device
The REMKO temperature control is an external, wall-mounted automatic day and night temperature control with separate preset options for the desired temperature.
Day and night temperatures can be set separately via the respective thermostats. The integrated weekly clock timer (TIMER with power re­serve) lets heating operation be pre-programmed for the week.
There are two models of the wall-mounted REMKO temperature control available:
1. Control without external cabling ATR-1
The electrical connection and the connection to the warm air heater have to be installed by authorised electrical personnel on the cus­ tomer-side in accordance with the wiring diagram (page 7).
2. Ready for plug in control ATR-2
The electrical connection is performed via an attached power cord 230 V and a 10 m long control cable with thermostat plug for con nection to the REMKO warm air heater with thermostat socket.
Day thermostat
Temperature sensor
Power control light
The REMKO temperature control may only be attached to the ther­mostat connection of the warm air heater intended for this purpose.
G
2
Night thermostat
Timer
Mode selector
Functionality
The desired room temperature is set on either the day or night thermo­stats.
The thermostats can be set using the 3-stage mode selector.
Mode - DAY The room temperature is only controlled via the day thermostat.
OFF No control function, the temperature function is switched off, the heating function is also off for the warm air heater.
Mode - TIMER The room temperature is controlled by the pre-programmed times and the set day/night temperatures.
Initial Operation
Position the housing with the temperature sensors in such a way that op­timum sensor function is guaranteed.
If the temperature control is mounted on cold, outdoor walls, the cus­tomer must install an insulation panel between the wall and the thermo­stat.
The thermostat sensors may not be directly exposed to a particu-
G
larly cold or hot stream of air.
Þ ATR-1; Temperature control without external cabling:
l Have the temperature control connected and put into operation by authorised personnel in accordance with the wiring diagram (page 7).
Þ ATR-2; Ready for plug in temperature control:
l Connect the plug of the thermostat cord to the thermostat socket of the warm air heater.
l Connect the power cord to a properly installed socket (~230V/50Hz). The green control lamp should now light up.
To maintain the timer function, the power current supply must be
G
not be interrupted.
l The unit is ready for operation once the timer, the selection switch and the desired room temperature have been set.
3
Timer display
Minutes
Selection arrow
Switch segment
Time
Day of the week
Rotating selector
Setting the day and time
This procedure is required:
1. For initial operation
2. When setting and resetting the clock for daylight savings time
3. After a long period with no power supply
4
Rotate the switch in the direction of the arrow until the current day is next to the selection arrow.
E.g. Fr = Friday.
The timer has a power reserve (approx. 120 h). If the power supply to the temperature control is interrupted for a longer period of
G
time, the timer must be reprogrammed.
Turn the minutes pointer in the di­rection of the arrow until the current time appears next to the selection arrow.
E.g. Fr 9:00 o‘clock.
Setting and programming example:
DAY mode Room temp. 20 °C (Day thermostat)
TIMER mode Room temp. 20 °C (Day thermostat)
Room temp. 10 °C (Night thermostat)
ON OFF
Setting the Timer
The timer function can only be set if the switch segment has been pressed out!
Segment pressed out ð Day temperature
Segment pressed in
The activation times are set via the green switch segments.
7 x 12 = 84 segment .
1 switch segment = 2 hours
The corresponding switch segments are pressed out using for example, a screwdriver.
Each day of the week is set individually.
ð Night temperature
5
Sample timer setting:
Current day: Friday (Fr)
Current time: 15:00 o‘clock
Selection switch position: Timer mode
Timer activation functions:
Mo - Fr: Switched off: 00:00 to 06:00 o‘clock
Switched on: 06:00 to 16:00 o‘clock Switched off: 16:00 to 24:00 o‘clock
Sa - So: Switched off: 00:00 to 08:00 o‘clock Switched on: 08:00 to 12:00 o‘clock Switched off: 12:00 to 24:00 o‘clock
The day thermostat is active during the times when the unit is switched on. When switched off, the night thermostat is active.
6
Wiring diagram
Thermostat connection
H = Power control light (green) K1T = Timer KL = Terminal strip RT-N = Night thermostat RT-T = Day thermostat S = Mode selector (1 = Day, 0 = Off, 2 = Timer)
Only have the REMKO ATR-1 temperature control installed and put into operation by authorised personnel in accordance with the
G
relevant regulations.
Operation/handling which does not comply with these instructions is prohibited! In cases of non-compliance, we assume no liability and the guarantee becomes null and void.
7
REMKO GmbH & Co. KG
Klima- und Wärmetechnik
D-32791 Lage Im Seelenkamp 12 D-32777 Lage PO Box 1827 Phone +49 (5232) 606 - 0 Fax +49 (5232) 606260 E-Mail: info@remko.de Internet: www.remko.de