The REMKO temperature control is an external, wall-mounted automatic
day and night temperature control with separate preset options for the
desired temperature.
Day and night temperatures can be set separately via the respective
thermostats. The integrated weekly clock timer (TIMER with power reserve) lets heating operation be pre-programmed for the week.
There are two models of the wall-mounted REMKO temperature control
available:
1. Control without external cabling ATR-1
The electrical connection and the connection to the warm air heater
have to be installed by authorised electrical personnel on the cus tomer-side in accordance with the wiring diagram (page 7).
2. Ready for plug in control ATR-2
The electrical connection is performed via an attached power cord
230 V and a 10 m long control cable with thermostat plug for con
nection to the REMKO warm air heater with thermostat socket.
Day thermostat
Temperature sensor
Power control light
The REMKO temperature control may only be attached to the thermostat connection of the warm air heater intended for this purpose.
G
2
Night thermostat
Timer
Mode selector
Functionality
The desired room temperature is set on either the day or night thermostats.
The thermostats can be set using the 3-stage mode selector.
Mode - DAY The room temperature is only controlled via the day
thermostat.
OFF No control function, the temperature function is
switched off, the heating function is also off for the
warm air heater.
Mode - TIMER The room temperature is controlled by the
pre-programmed times and the set day/night
temperatures.
Initial Operation
Position the housing with the temperature sensors in such a way that optimum sensor function is guaranteed.
If the temperature control is mounted on cold, outdoor walls, the customer must install an insulation panel between the wall and the thermostat.
The thermostat sensors may not be directly exposed to a particu-
G
larly cold or hot stream of air.
Þ ATR-1; Temperature control without external cabling:
l Have the temperature control connected and put into operation by
authorised personnel in accordance with the wiring diagram (page 7).
Þ ATR-2; Ready for plug in temperature control:
l Connect the plug of the thermostat cord to the thermostat socket of
the warm air heater.
l Connect the power cord to a properly installed socket (~230V/50Hz).
The green control lamp should now light up.
To maintain the timer function, the power current supply must be
G
not be interrupted.
l The unit is ready for operation once the timer, the selection switch
and the desired room temperature have been set.
3
Timer display
Minutes
Selection arrow
Switch segment
Time
Day of the week
Rotating selector
Setting the day and time
This procedure is required:
1. For initial operation
2. When setting and resetting the clock for daylight savings time
3. After a long period with no power supply
4
Rotate the switch in the direction of
the arrow until the current day is
next to the selection arrow.
E.g. Fr = Friday.
The timer has a power reserve (approx. 120 h). If the power supply
to the temperature control is interrupted for a longer period of
G
time, the timer must be reprogrammed.
Turn the minutes pointer in the direction of the arrow until the current
time appears next to the selection
arrow.
E.g. Fr 9:00 o‘clock.
Setting and programming example:
DAY mode
Room temp. 20 °C
(Day thermostat)
TIMER mode
Room temp. 20 °C
(Day thermostat)
Room temp. 10 °C
(Night thermostat)
ON OFF
Setting the Timer
The timer function can only be set if the switch segment has been
pressed out!
Segment pressed out ð Day temperature
Segment pressed in
The activation times are set via the green switch segments.
7 x 12 = 84 segment .
1 switch segment = 2 hours
The corresponding switch segments are pressed out using for example,
a screwdriver.
Each day of the week is set individually.
ð Night temperature
5
Sample timer setting:
Current day: Friday (Fr)
Current time: 15:00 o‘clock
Selection switch position: Timer mode
Timer activation functions:
Mo - Fr:
Switched off: 00:00 to 06:00 o‘clock
Switched on: 06:00 to 16:00 o‘clock
Switched off: 16:00 to 24:00 o‘clock
Sa - So:
Switched off: 00:00 to 08:00 o‘clock
Switched on: 08:00 to 12:00 o‘clock
Switched off: 12:00 to 24:00 o‘clock
The day thermostat is active during the times when the unit is switched
on. When switched off, the night thermostat is active.
6
Wiring diagram
Thermostat connection
H = Power control light (green)
K1T = Timer
KL = Terminal strip
RT-N = Night thermostat
RT-T = Day thermostat
S = Mode selector (1 = Day, 0 = Off, 2 = Timer)
Only have the REMKO ATR-1 temperature control installed and
put into operation by authorised personnel in accordance with the
G
relevant regulations.
Operation/handling which does not comply with these instructions is
prohibited! In cases of non-compliance, we assume no liability and the
guarantee becomes null and void.
7
REMKO GmbH & Co. KG
Klima- und Wärmetechnik
D-32791 Lage • Im Seelenkamp 12
D-32777 Lage • PO Box 1827
Phone +49 (5232) 606 - 0
Fax +49 (5232) 606260
E-Mail: info@remko.de
Internet: www.remko.de
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.