Read and understand this manual before assembling, starting or servicing
heater. Improper use of heater can cause serious injury. Keep this manual
for future reference.
IMPORTANT: Read this Owner’s Manual carefully and completely
before trying to assemble, operate, or service this heater. Improper
use of this heater can cause serious injury or death from burns, fire,
explosion, electrical shock, and carbon monoxide poisoning.
DANGER
Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning
resemble the flu, with headaches, dizziness, and/or nausea. If you have these
signs, the heater may not be working properly. Get fresh air at once! Have
heater serviced. Some people are more affected by carbon monoxide than others.
These include pregnant women, persons with heart or lung disease or anemia,
those under the influence of alcohol, and those at high altitudes.
Make certain you read and understand all Warnings. Keep this manual for
reference. It is your guide to safe and proper operation of this heater.
102961
SAFETY
INFORMATION
Continued
WARNINGS
• Use only kerosene to avoid risk of fire or explosion. Never use gasoline, naphtha, paint
thinners, alcohol, or other highly flammable fuels.
• Fueling
a) Personnel involved with fueling shall be qualified and thoroughly familiar with
the manufacturer's instructions and applicable federal, state, and local regula-
tions regarding the safe fueling of heating units.
b) Only the type of fuel specified on the heater's data plate shall be used.
c) All flame, including the pilot light, if any, shall be extinguished and the heater
allowed to cool, prior to fueling.
d) During fueling, all fuel lines and fuel-line connections shall be inspected for leaks.
Any leaks shall be repaired prior to returning the heater to service.
e) At no time shall more than one day's supply of heater fuel be stored inside a
building in the vicinity of the heater . Bulk fuel stor age shall be outside the struc-
ture.
f) All fuel storage shall be located a minimum of 25 feet (762 cm) from heaters,
torches, welding equipment, and similar sources of ignition (exception: the fuel
reservoir integral with the heater unit).
g) Whenever possible, fuel storage shall be confined to areas where floor penetra-
tions do not permit fuel to drip onto or be ignited by a fire at lower elevation.
h) Fuel storage shall be in accordance with the authority having jurisdiction.
• Never use heater where gasoline, paint thinner, or other highly flammable vapors are
present.
• Follow all ordinances and codes when using heater.
• Heaters used in the vicinity of tarpaulins, canvas, or similar enclosure materials
shall be located a safe distance from such materials. The recommended minimum safe distance is 10 feet (305 cm). It is further recommended that these
enclosure materials be of a fire retardant nature. These enclosure materials shall
be securely fastened to prevent them from igniting or from upsetting the heater
due to wind action.
• Use only in well-vented areas. Before using heater, provide at least a three-squarefoot opening of fresh, outside air for each 100,000 Btu/Hr of rating.
• Use only in places free of flammable vapors or high dust content.
• Use only the electrical voltage and frequency specified on model plate.
• Use only a grounded extension cord.
• Minimum heater clearances from combustibles:
Outlet: 8 Ft. (250 cm)Sides,Top, and Rear: 4 Ft. (125 cm)
• Locate heater on a stable and level surface if heater is hot or running or a fire may
occur.
• When moving or storing heater, keep heater in a level position or fuel spillage may
occur.
• Keep children and animals away from heater.
• Unplug heater when not in use.
• When used with thermostat, heater may start anytime.
• Never use heater in living or sleeping areas.
• Never block air inlet (rear) or air outlet (front) of heater.
• Never move, handle, refuel, or service a hot, operating, or plugged-in heater.
• Never attach duct work to front or rear of heater.
(Continued)
102961
3
PRODUCT
IDENTIFICATION
Hot Air Outlet
Upper Shell
Lower Shell
Fuel Gauge
Fuel Tank
ON/OFF Switch
Flame-Out Control
Reset Button
Hot Air
Outlet
Fan Guard
Air Filter
End Cover
Fuel Cap
Side Cover
Power Cord
Figure 1 - REMJ70
Upper Shell
Lower
Shell
Fuel Cap
Side Cover
ON/OFF Switch
Fuel Gauge
Power Cord
Figure 2 - REMJ150
Fan Guard
Fuel
Tank
Flame-Out Control
Reset Button
4
102961
UNPACKING
1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check items for any shipping damage. If heater is damaged, promptly inform
dealer where you bought heater.
ASSEMBLY
These models are furnished with wheels and handles. Wheels, handles, and the
mounting hardware are found in the shipping carton.
Tools Needed
• Medium Phillips Screwdriver
• 3/8" Open or Adjustable Wrench
• Hammer
1. Slide axle through wheel support frame. Install wheels on axle.
IMPORTANT:
wheel support frame (see Figure 3).
2. Place cap nuts on axle ends. Gently tap with hammer to secure.
3. Place heater on wheel support frame. Line up holes on fuel tank flange with
holes on wheel support frame.
70 Model: Make sure hot air outlet end (front) of heater is over wheels.
150 Model: Make sure air inlet end (rear) of heater is over wheels.
4. Place handle or handles on top of fuel tank flange. Insert screws through
handle(s), fuel tank flange, and wheel support frame. Attach nut finger tight
after each screw is inserted.
5. After all screws are inserted, tighten nuts firmly.
Hot Air
Outlet
When installing wheels, point extended hub of wheels toward
70 Model
Screw
Handle
Fuel Tank
Flange
Cap
Nut
Axle
Nut
Wheel
Wheel Support
Frame
Extended
Hub
Fuel Tank
Flange
Wheel
Support
Frame
Cap Nut
Air
Inlet
Screw
Nut
150 Model
Front
Handle
Wheel
Axle
Rear
Handle
Air
Inlet
Extended
Hub
102961
Figure 3 - Wheel and Handle Assembly
5
THEORY OF
OPERATION
The Fuel System: The air pump forces air through the air line. The air is then
pushed through the burner head nozzle. This air causes fuel to lift from the tank. A
fine mist of fuel is sprayed into the combustion chamber.
The Air System: The motor turns the fan. The fan pushes air into and around
the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The electronic ignitor sends voltage to the spark plug.
The spark plug ignites the fuel and air mixture.
The Flame-Out Control System: This system causes the heater to shut down
if the flame goes out.
Clean
Heated
Air Out
Fuel
Tank
Combustion
Chamber
Nozzle
Air For Fuel
System
Figure 4 - Cross Section Operational View
Spark
Plug
Fuel
Filter
Burner
Head
Air For Combustion
And Heating
Motor
Fan
Air line
To Burner
Air Pump
Intake
Air
Filter
Cool
Air
In
Output
Air
Filter
Electronic
Ignitor
Fuel
FUELS
WARNING
Use only kerosene or No. 1 fuel oil to avoid risk of fire or
explosion. Never use gasoline, naphtha, paint thinners,
alcohol or other highly flammable fuels.
Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels
will result in:
• clogged fuel filter and nozzle
• carbon build up on spark plug
• use of non-toxic anti-icer in fuel during very cold weather
IMPORTANT:
clean. Foreign matter such as rust, dirt, or water will cause the flame-out control to
shut down heater. Foreign matter may also require you to clean fuel system often.
6
Use a KEROSENE ONLY container. Be sure storage container is
102961
VENTILATION
WARNING
Follow the minimum fresh, outside air ventilation
requirements. If proper fresh, outside air ventilation is not
provided, carbon monoxide poisoning can occur. Provide
proper fresh, outside air ventilation before running heater.
Provide a fresh air opening of at least three square feet (2800 square cm) for each
100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.
OPERATION
Example:
A 150,000 Btu/Hr heater requires one of the following:
• a two-car garage door (5 m wide opening) raised 8.6 cm.
• a single-car garage door (2.75 m wide opening) raised 15.3 cm.
• two, 76.2 cm wide windows raised 28 cm.
WARNING
Review and understand the warnings in the
Information Section
operate this heater. Follow all local codes when using this
heater.
, page 3. They are needed to safely
To Start Heater
1. Follow all ventilation and safety information.
2. Fill fuel tank with kerosene.
3. Attach fuel cap.
4. Plug power cord into grounded receptacle with 100 Volts, 50 or 60 Hz.
5. Turn ON/OFF switch to "ON".
Extension Cord Wire Size Requirements
Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm2) conductor
101 to 200 feet (30.6 to 61 meters) long, use 14 AWG (1.5 mm2) conductor
If heater does not start, push in flame-out control reset button (see Figures 5
and 6).
Safety
102961
FlameOut
Control
Reset
Button
Figure 5 - Flame-Out Control Reset
Button (REMJ70)
Flame-Out
Control
Reset
Button
Figure 6 - Flame-Out Control Reset
Button (REMJ150)
Continued
7
OPERATION
Continued
STORING,
TRANSPORTING,
OR SHIPPING
To Stop Heater
1. Turn ON/OFF switch to “OFF.”
2. Unplug power cord from outlet.
To Restart Heater
1. Wait 2 minutes after stopping heater.
2. Repeat steps under To Start Heater, page 7.
Note:
If shipping, transport companies require fuel tanks to be empty.
1. Drain fuel tank by removing drain plug on underside of fuel tank.
2. Replace drain plug.
3. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir,
and drain again. This will prevent excess debris from clogging filters during
future use.
4. Replace drain plug. Properly dispose of old and dirty fuel. Check with local
automotive service stations that recycle oil.
5. If storing, store heater in dry place. Make sure storage place is free of dust and
corrosive fumes.
PREVENTA TIVE
MAINTENANCE
SCHEDULE
IMPORTANT:
heating season. Using old fuel could damage heater.
Do not store kerosene over summer months for use during next
WARNING
Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.
ItemHow OftenHow To
Fuel tankFlush every 150-200 hoursSee Storing, Transporting, or
of operation or as needed.Shipping, above.
Air output andReplace every 500 hours ofSee Air Output, Air Intake,
lint filters operation or once and Lint Filters, page 12.
a year.
Air intakeWash and dry with soap andSee Air Output, Air Intake,
filter water every 500 hours of and Lint Filters, page 12.
operation or as needed.
Fuel filterClean twice a heating seasonSee Fuel Filter, pages 10
or as needed. and 11.
Spark plugClean and regap every 600See Spark Plug, page 11.
hours operation or replace
as needed.
Fan bladesClean every season or as needed.See Fan, page 15.
MotorNot required/permanently
lubricated
8