Remington REMJ70, REMJ150 User Manual

PORTABLE
150 SIDE HANDLE
PFA/PV 005
FORCED
AIR HEATERS
OWNER’S MANUAL
®
REMJ70
REMJ150
Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
CONTENTS
SECTION PAGE
Safety Information.........................................................................2
Product Identification .................................................................... 4
Unpacking......................................................................................5
Assembly .......................................................................................5
Theory of Operation ......................................................................6
Fuels .............................................................................................. 6
Ventilation .....................................................................................7
Operation .......................................................................................7
Storing, Transporting, or Shipping ................................................ 8
Preventative Maintenance Schedule..............................................8
Troubleshooting.............................................................................9
Service Procedures ........................................................................ 10
Upper Shell Removal .............................................................. 10
Fuel Filter (REMJ70) .............................................................. 10
Fuel Filter (REMJ150) ............................................................ 11
Spark Plug ............................................................................... 11
Air Output, Air Intake, and Lint Filters ..................................12
Pump Pressure Adjustment ..................................................... 12
Nozzle .....................................................................................13
Pump Rotor .............................................................................14
Fan...........................................................................................15
Specifications.................................................................................15
Illustrated Parts Breakdown and Parts List ................................... 16
REMJ70 .................................................................................. 16
REM150 .................................................................................. 18
Wheels and Handles................................................................20
Wiring Diagram.............................................................................21
Accessories .................................................................................... 21
SAFETY
INFORMATION
2
WARNINGS
IMPORTANT: Read this Owners Manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, re, explosion, electrical shock, and carbon monoxide poisoning.
DANGER
Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning
resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
102961
SAFETY
INFORMATION
Continued
WARNINGS
• Use only kerosene to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
• Fueling a) Personnel involved with fueling shall be qualified and thoroughly familiar with
the manufacturer's instructions and applicable federal, state, and local regula-
tions regarding the safe fueling of heating units. b) Only the type of fuel specified on the heater's data plate shall be used. c) All flame, including the pilot light, if any, shall be extinguished and the heater
allowed to cool, prior to fueling. d) During fueling, all fuel lines and fuel-line connections shall be inspected for leaks.
Any leaks shall be repaired prior to returning the heater to service. e) At no time shall more than one day's supply of heater fuel be stored inside a
building in the vicinity of the heater . Bulk fuel stor age shall be outside the struc-
ture. f) All fuel storage shall be located a minimum of 25 feet (762 cm) from heaters,
torches, welding equipment, and similar sources of ignition (exception: the fuel
reservoir integral with the heater unit). g) Whenever possible, fuel storage shall be confined to areas where floor penetra-
tions do not permit fuel to drip onto or be ignited by a fire at lower elevation. h) Fuel storage shall be in accordance with the authority having jurisdiction.
• Never use heater where gasoline, paint thinner, or other highly flammable vapors are present.
• Follow all ordinances and codes when using heater.
• Heaters used in the vicinity of tarpaulins, canvas, or similar enclosure materials shall be located a safe distance from such materials. The recommended mini­mum safe distance is 10 feet (305 cm). It is further recommended that these enclosure materials be of a fire retardant nature. These enclosure materials shall be securely fastened to prevent them from igniting or from upsetting the heater due to wind action.
• Use only in well-vented areas. Before using heater, provide at least a three-square­foot opening of fresh, outside air for each 100,000 Btu/Hr of rating.
• Use only in places free of flammable vapors or high dust content.
• Use only the electrical voltage and frequency specified on model plate.
• Use only a grounded extension cord.
• Minimum heater clearances from combustibles:
Outlet: 8 Ft. (250 cm) Sides,Top, and Rear: 4 Ft. (125 cm)
• Locate heater on a stable and level surface if heater is hot or running or a fire may occur.
• When moving or storing heater, keep heater in a level position or fuel spillage may occur.
• Keep children and animals away from heater.
• Unplug heater when not in use.
• When used with thermostat, heater may start anytime.
• Never use heater in living or sleeping areas.
• Never block air inlet (rear) or air outlet (front) of heater.
• Never move, handle, refuel, or service a hot, operating, or plugged-in heater.
• Never attach duct work to front or rear of heater.
(Continued)
102961
3
PRODUCT
IDENTIFICATION
Hot Air Outlet
Upper Shell
Lower Shell Fuel Gauge
Fuel Tank
ON/OFF Switch
Flame-Out Control Reset Button
Hot Air Outlet
Fan Guard
Air Filter End Cover
Fuel Cap
Side Cover
Power Cord
Figure 1 - REMJ70
Upper Shell
Lower Shell
Fuel Cap
Side Cover
ON/OFF Switch
Fuel Gauge
Power Cord
Figure 2 - REMJ150
Fan Guard
Fuel Tank
Flame-Out Control Reset Button
4
102961
UNPACKING
1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check items for any shipping damage. If heater is damaged, promptly inform
dealer where you bought heater.
ASSEMBLY
These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton.
Tools Needed
• Medium Phillips Screwdriver
• 3/8" Open or Adjustable Wrench
• Hammer
1. Slide axle through wheel support frame. Install wheels on axle.
IMPORTANT:
wheel support frame (see Figure 3).
2. Place cap nuts on axle ends. Gently tap with hammer to secure.
3. Place heater on wheel support frame. Line up holes on fuel tank flange with
holes on wheel support frame.
70 Model: Make sure hot air outlet end (front) of heater is over wheels. 150 Model: Make sure air inlet end (rear) of heater is over wheels.
4. Place handle or handles on top of fuel tank flange. Insert screws through
handle(s), fuel tank flange, and wheel support frame. Attach nut finger tight after each screw is inserted.
5. After all screws are inserted, tighten nuts firmly.
Hot Air Outlet
When installing wheels, point extended hub of wheels toward
70 Model
Screw
Handle
Fuel Tank Flange
Cap Nut
Axle
Nut
Wheel
Wheel Support Frame
Extended Hub
Fuel Tank Flange
Wheel Support Frame
Cap Nut
Air Inlet
Screw
Nut
150 Model
Front Handle
Wheel
Axle
Rear Handle
Air Inlet
Extended Hub
102961
Figure 3 - Wheel and Handle Assembly
5
THEORY OF
OPERATION
The Fuel System: The air pump forces air through the air line. The air is then
pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The electronic ignitor sends voltage to the spark plug. The spark plug ignites the fuel and air mixture.
The Flame-Out Control System: This system causes the heater to shut down if the flame goes out.
Clean Heated Air Out
Fuel Tank
Combustion Chamber
Nozzle
Air For Fuel System
Figure 4 - Cross Section Operational View
Spark Plug
Fuel Filter
Burner Head
Air For Combustion And Heating
Motor
Fan
Air line To Burner
Air Pump
Intake Air Filter
Cool Air In
Output Air Filter
Electronic Ignitor
Fuel
FUELS
WARNING
Use only kerosene or No. 1 fuel oil to avoid risk of re or explosion. Never use gasoline, naphtha, paint thinners, alcohol or other highly ammable fuels.
Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in:
• clogged fuel filter and nozzle
• carbon build up on spark plug
• use of non-toxic anti-icer in fuel during very cold weather
IMPORTANT:
clean. Foreign matter such as rust, dirt, or water will cause the flame-out control to shut down heater. Foreign matter may also require you to clean fuel system often.
6
Use a KEROSENE ONLY container. Be sure storage container is
102961
VENTILATION
WARNING
Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
Provide a fresh air opening of at least three square feet (2800 square cm) for each 100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.
OPERATION
Example:
A 150,000 Btu/Hr heater requires one of the following:
• a two-car garage door (5 m wide opening) raised 8.6 cm.
• a single-car garage door (2.75 m wide opening) raised 15.3 cm.
• two, 76.2 cm wide windows raised 28 cm.
WARNING
Review and understand the warnings in the
Information Section
operate this heater. Follow all local codes when using this heater.
, page 3. They are needed to safely
To Start Heater
1. Follow all ventilation and safety information.
2. Fill fuel tank with kerosene.
3. Attach fuel cap.
4. Plug power cord into grounded receptacle with 100 Volts, 50 or 60 Hz.
5. Turn ON/OFF switch to "ON".
Extension Cord Wire Size Requirements
Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm2) conductor 101 to 200 feet (30.6 to 61 meters) long, use 14 AWG (1.5 mm2) conductor
If heater does not start, push in flame-out control reset button (see Figures 5 and 6).
Safety
102961
Flame­Out Control Reset Button
Figure 5 - Flame-Out Control Reset
Button (REMJ70)
Flame-Out Control Reset Button
Figure 6 - Flame-Out Control Reset
Button (REMJ150)
Continued
7
OPERATION
Continued
STORING,
TRANSPORTING,
OR SHIPPING
To Stop Heater
1. Turn ON/OFF switch to “OFF.”
2. Unplug power cord from outlet.
To Restart Heater
1. Wait 2 minutes after stopping heater.
2. Repeat steps under To Start Heater, page 7.
Note:
If shipping, transport companies require fuel tanks to be empty.
1. Drain fuel tank by removing drain plug on underside of fuel tank.
2. Replace drain plug.
3. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters during future use.
4. Replace drain plug. Properly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil.
5. If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.
PREVENTA TIVE MAINTENANCE
SCHEDULE
IMPORTANT:
heating season. Using old fuel could damage heater.
Do not store kerosene over summer months for use during next
WARNING
Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
Item How Often How To
Fuel tank Flush every 150-200 hours See Storing, Transporting, or
of operation or as needed. Shipping, above.
Air output and Replace every 500 hours of See Air Output, Air Intake,
lint filters operation or once and Lint Filters, page 12. a year.
Air intake Wash and dry with soap and See Air Output, Air Intake, filter water every 500 hours of and Lint Filters, page 12.
operation or as needed.
Fuel filter Clean twice a heating season See Fuel Filter, pages 10
or as needed. and 11.
Spark plug Clean and regap every 600 See Spark Plug, page 11.
hours operation or replace
as needed. Fan blades Clean every season or as needed. See Fan, page 15. Motor Not required/permanently
lubricated
8
102961
Loading...