REMEHA Quinta Ace Installation, User And Service Manual

United Kingdom
en
Installation, user and service manual
High-efficiency wall-hung gas boiler
Quinta Ace
160
Thank you very much for buying this appliance.
Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer service organisation can assist with this.
We hope you enjoy years of problem-free operation with the product.
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.3 Specific safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.3.1 Additional guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4 Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 Additional documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.3 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.3.1 Symbols used in the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.4 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1 Homologations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.1 Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.2 Unit categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3.1.3 Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3.1.4 Factory test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3.3 Dimensions and connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.4 Electrical diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4 Description of the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.2 Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2.1 Gas/air regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2.2 Combustion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2.3 Control system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.2.4 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2.5 Regulating the water temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2.6 Protection against shortage of water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2.7 Water flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2.8 Hydraulic pressure sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2.9 Air pressure differential switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
4.2.10 Circulating pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.2.11 Calorifier connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.2.12 Cascade system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.3 Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.4 Control panel description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.5 Standard delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.6 Accessories and options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5 Before installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.1 Installation regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.2 Lifting instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.3 Choice of the location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.3.1 Type plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.3.2 Location of the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.4 Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
5.5 Unpacking & initial preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.2 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.2.1 Positioning the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.3 Hydraulic connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
6.3.1 Rinsing the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.3.2 Connecting the heating circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.3.3 Connecting the expansion vessel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Contents
7625116 - v.04 - 17012017 3
6.3.4 Connecting the condensate drain pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4 Gas connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.5 Air supply/flue gas connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.5.1 Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.5.2 Outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.5.3 Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.5.4 Length of the air and flue gas pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
6.5.5 Specific air and flue gas applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
6.5.6 Additional guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.5.7 Connecting the flue gas outlet and air supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.6 Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.6.1 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
6.6.2 Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.6.3 Assembly of the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
6.6.4 Connecting the connection box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.6.5 Connection options for the standard PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.7 Connecting a PC/laptop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.8 Filling the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
6.8.1 Water treatment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
6.8.2 Filling the siphon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6.8.3 Filling the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
7 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.1 Checklist before commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.1.1 Preparing the boiler for commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.1.2 Gas circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.1.3 Hydraulic circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.1.4 Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.2 Commissioning procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.3 Gas settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
7.3.1 Adjusting to a different gas type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
7.3.2 Checking/setting combustion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
7.4 Final instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
8 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
8.1 Use of the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8.2 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8.3 Frost protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
9 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
9.1 Description of the user level parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
9.2 Description of the installer level parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
9.3 Changing the parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
9.4 Reading out measured values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.4.1 Reading out current values (counters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
9.4.2 Reading out current values (signals) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.4.3 Status and sub-status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
10 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
10.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
10.2 Maintenance message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
10.2.1 Resetting the service messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
10.2.2 Starting a new service interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
10.3 Standard inspection and maintenance operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
10.3.1 Checking the water pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
10.3.2 Checking the water quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
10.3.3 Checking the ionisation current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
10.3.4 Checking the flue gas discharge/air supply connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
10.3.5 Checking the combustion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
10.3.6 Checking the PS air pressure differential switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
10.3.7 Checking the automatic air vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
10.3.8 Checking the burner and cleaning the heat exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
10.3.9 Clean the condensate collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
10.3.10 Cleaning the siphon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
10.4 Specific maintenance work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
10.4.1 Replacing the ionisation/ignition electrode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Contents
4 7625116 - v.04 - 17012017
10.4.2 Checking the non-return valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
10.4.3 Reassembling the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
11.1 Removal/recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
12 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
12.1 Error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
12.1.1 Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
12.1.2 Blocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
12.1.3 Lock-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
12.2 Error memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
13 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
13.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
13.2 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
14 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
14.1 ErP information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
14.1.1 Product fiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
14.2 EC declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
14.3 Checklist for commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
14.4 Checklist for annual maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Contents
7625116 - v.04 - 17012017 5
1 Safety
1.1 General safety instructions
For the installer:
Danger If you smell gas:
1. Do not use naked flames, do not smoke and do not operate electrical contacts or switches (doorbell, lighting, motor, lift etc).
2. Shut off the gas supply.
3. Open the windows.
4. Trace possible leaks and seal them off imme diately.
5. If the leak is upstream of the gas meter, notify the gas company.
Danger If you smell flue gases:
1. Switch the boiler off.
2. Open the windows.
3. Trace possible leaks and seal them off imme diately.
Caution After maintenance or repair work, check the en tire heating installation to ensure that there are no leaks.
For the end user:
1 Safety
6 7625116 - v.04 - 17012017
Danger If you smell gas:
1. Do not use naked flames, do not smoke and do not operate electrical contacts or switches (doorbell, lighting, motor, lift etc).
2. Shut off the gas supply.
3. Open the windows.
4. Report any leaks immediately.
5. Evacuate the property.
6. Contact a qualified installer.
Danger If you smell flue gases:
1. Switch the boiler off.
2. Open the windows.
3. Report any leaks immediately.
4. Evacuate the property.
5. Contact a qualified installer.
Warning Do not touch the flue gas pipes. Depending on the boiler settings, the temperature of the flue gas pipes can rise to over 60°C.
Warning Do not touch radiators for long periods. Depend ing on the boiler settings, the temperature of the radiators can rise to over 60°C.
Warning The use of the boiler and the installation by you as the end-user must be limited to the operations described in this manual. All other actions may only be undertaken by a qualified fitter/engineer.
Caution Ensure that the boiler is regularly serviced. Con tact a qualified installer or arrange a maintenance contract for the servicing of the boiler.
Caution Only genuine spare parts may be used.
Important Regularly check for the presence of water and pressure in the heating installation.
1 Safety
7625116 - v.04 - 17012017 7
1.2 Recommendations
Danger This appliance can be used by children aged eight and above and people with a physical, sen sory or mental disability, or with a lack of experi ence and knowledge, provided they are super vised and instructed in how to use the appliance in a safe manner and understand the associated dangers. Children must not be allowed to play with the appliance. Cleaning and user mainte nance should not be carried out by children with out adult supervision.
Warning Installation and maintenance of the boiler must be carried out by a qualified installer in accordance with local and national regulations.
Warning The installation and maintenance of the boiler must be undertaken by a qualified installer in ac cordance with the information in the supplied manual, doing otherwise may result in dangerous situations and/or bodily injury.
Warning Removal and disposal of the boiler must be car ried out by a qualified installer in accordance with local and national regulations.
Warning If the mains lead is damaged, it must be replaced by the original manufacturer, the manufacturer's dealer or another suitably skilled person to pre vent hazardous situations from arising.
Warning Always disconnect the mains supply and close the main gas tap when working on the boiler.
Warning Check the entire system for leaks after mainte nance and servicing work.
Danger For safety reasons, we recommend fitting smoke and CO alarms at suitable places in your home.
1 Safety
8 7625116 - v.04 - 17012017
Caution
Make sure the boiler can be reached at all times. The boiler must be installed in a frost-free area. If the power cord is permanently connected, you must always install a main bipolar switch with an opening gap of at least 3 mm (BS EN 60335-1). Drain the boiler and central heating system if you are not going to use your home for a long time and there is a chance of frost. The frost protection does not work if the boiler is out of operation. The boiler protection only protects the boiler, not the system. Check the water pressure in the system regular ly. If the water pressure is lower than 0.8 bar, the system must be topped up (recommended water pressure between 1.5 and 2 bar)
.
Important Keep this document near to the boiler.
Important Only remove the casing for maintenance and re pair operations. Refit all panels when mainte nance work and servicing are complete.
Important Instruction and warning labels must never be re moved or covered and must be clearly legible throughout the entire service life of the boiler. Damaged or illegible instructions and warning stickers must be replaced immediately.
Important Modifications to the boiler require the written ap proval of Remeha.
1.3
Specific safety instructions
1.3.1 Additional guidelines
In addition to the legal requirements and guidelines, the supplementary guidelines in this manual must also be followed. Supplements or subsequent regulations and guidelines that are valid at the time of installation shall apply to all regulations and guidelines specified in this manual.
1 Safety
7625116 - v.04 - 17012017 9
1.4 Liabilities
1.4.1 Manufacturer's liability
Our products are manufactured in compliance with the requirements of the various Directives applicable. They are therefore delivered with the marking and any documents necessary. In the interests of the quality of our products, we strive constantly to improve them. We therefore reserve the right to modify the specifications given in this document.
Our liability as manufacturer may not be invoked in the following cases:
Failure to abide by the instructions on installing the appliance. Failure to abide by the instructions on using the appli ance. Faulty or insufficient maintenance of the appliance.
1.4.2
Installer's liability
The installer is responsible for the installation and initial commissioning of the appliance. The installer must ob serve the following instructions:
Read and follow the instructions given in the manuals provided with the appliance. Install the appliance in compliance with prevailing leg islation and standards. Carry out initial commissioning and any checks neces sary. Explain the installation to the user. If maintenance is necessary, warn the user of the obli gation to check the appliance and keep it in good working order. Give all the instruction manuals to the user.
1.4.3 User's liability
To guarantee optimum operation of the system, you must abide by the following instructions:
Read and follow the instructions given in the manuals provided with the appliance. Call on a qualified professional to carry out installation and initial commissioning. Get your installer to explain your installation to you. Have the required inspections and maintenance car ried out by a qualified installer. Keep the instruction manuals in good condition close to the appliance.
1 Safety
10 7625116 - v.04 - 17012017
2 About this manual
2.1 General
This manual describes the installation, use and maintenance of the Quinta Ace boiler. This manual is part of all the documentation supplied with the boiler.
2.2
Additional documentation
The following documentation is available in addition to this manual:
Installation and user manual for control panel Water quality instructions
2.3
Symbols used
2.3.1 Symbols used in the manual
This manual uses various danger levels to draw attention to special in structions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance.
Danger Risk of dangerous situations that may result in serious personal injury.
Danger of electric shock Risk of electric shock.
Warning Risk of dangerous situations that may result in minor personal in jury.
Caution Risk of material damage.
Important Please note: important information.
See Reference to other manuals or pages in this manual.
2.4
Abbreviations
PCU PCB for managing burner operation PWM Pulse wide modulation SU Safety PCB
2 About this manual
7625116 - v.04 - 17012017 11
3 Technical specifications
3.1 Homologations
3.1.1 Certifications
Tab.1 Certifications
CE identification number PIN 0063CQ3781
NOx class 6 (EN 15502-1)
Type of connection B
23P
, B
33
C13, C33, C43, C53, C63, C83, C
93
3.1.2 Unit categories
Tab.2 Unit categories
Country Category Gas type Connection pressure (mbar)
Great Britain II
2H3B/P
G20 (H gas) G30/G31 (butane/propane)
20 30-50
3.1.3 Directives
In addition to the legal requirements and guidelines, the supplementary guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at the time of installation shall apply to all regulations and guidelines speci fied in this manual.
3.1.4 Factory test
Before leaving the factory, each boiler is optimally set and tested for:
Electrical safety. Adjustment of (O2/CO2).
Water tightness. Gas tightness. Parameter setting.
3.2
Technical data
Tab.3 General
Quinta Ace 160
Nominal output (Pn) for central heating operation (80°C/60°C) min. - max.
(1)
kW 31.5 - 152.1
152.1
Nominal output (Pn) for central heating operation (50°C/30°C) min. - max.
(1)
kW 34.7 - 161.6
161.6
Nominal input (Qn) for central heating operation (Hi) G20 (H gas) min. - max.
(1)
kW 32.0 - 156.0
156.0
Nominal input (Qn) for central heating operation (Hi) G31 (Propane) min. - max. kW 40.0 - 156.0
Nominal input (Qn) for central heating operation (Hs) G20 (H gas) min. - max.
(1)
kW 35.6 - 173.3
173.3
3 Technical specifications
12 7625116 - v.04 - 17012017
Quinta Ace 160
Nominal input (Qn) for central heating operation (Hs) G31 (Propane) min. - max. kW 43.4 - 169.6
Full load central heating efficiency (Hi) (80/60°C) (92/42/EEC) % 97.5
Full load central heating efficiency (Hi) (50°C/30°C) (EN15502) % 103.6
Low load central heating efficiency (Hi) (return temperature 60°C) % 98.4
Part load central heating efficiency (92/42/EEC) (return temperature 30°C)
% 108.5
(1) Factory setting.
Tab.4 Gas and flue gas data
Quinta Ace 160
Gas inlet pressure G20 (H gas) min. - max. mbar 17 - 25
Gas inlet pressure G31 (propane) min. - max. mbar 37 - 50
Gas consumption G20 (H gas)
(1)
min. - max.
m3/h
3.4 - 16.5
Gas consumption G31 (propane)
(1)
min. - max.
m3/h
1.4 - 6.3
BREEAM NO
X
mg/kWh 36
Flue gas mass flow rate min. - max. kg/h
g/s
57 - 277
16 - 77
Flue gas temperature min. - max. °C 32 - 66
Maximum counter pressure Pa 200
(1) Gas consumption based on lower heating value under standard conditions: T=288.15 K, p=1013.25 mbar. Gag 30.33; G25 29.25; G31
88.00 MJ/m
3
Tab.5 Central heating circuit data
Quinta Ace 160
Water content l 17
Water operating pressure min bar 0.8
Water operating pressure (PMS) max bar 4.0
Water temperature max °C 110
Operating temperature max °C 90
Pressure drop secondary circuit (ΔT=20 K) mbar 170
Tab.6 Electrical data
Quinta Ace 160
Supply voltage VAC 230
Power consumption – full load max W 275
Power consumption – low load min W 47
Power consumption – standby min W 5.3
Electrical protection index IP IPX1B
Fuses Main
PCU
A A
6.3
1.6
3 Technical specifications
7625116 - v.04 - 17012017 13
Tab.7 Other data
Quinta Ace 160
Total weight (empty) kg 147
Minimum mounting weight (without front panel) kg 123
Average acoustic level at a distance of one metre from the boiler dB(A) 59.5
Tab.8 Technical parameters
Quinta Ace 160
Condensing boiler Yes
Low-temperature boiler
(1)
No
B1 boiler No
Cogeneration space heater No
Combination heater No
Rated heat output
Prated
kW 152
Useful heat output at nominal heat output and high temperature opera tion
(2)
P
4
kW 152.1
Useful heat output at 30% of rated heat output and low temperature re gime
(1)
P
1
kW 50.8
Seasonal space heating energy efficiency
ƞ
s
% -
Useful efficiency at rated heat output and high temperature regime
(2)
ƞ
4
% 87.8
Useful efficiency at 30% of rated heat output and low temperature re gime
(1)
ƞ
1
% 97.8
Auxiliary electricity consumption
Full load
elmax
kW 0.275
Part load
elmin
kW 0.047
Standby mode
P
SB
kW 0.005
Other items
Standby heat loss
P
stby
kW 0.191
Ignition burner power consumption
P
ign
kW -
Annual energy consumption
Q
HE
kWh GJ
-
Sound power level, indoors
L
WA
dB 68
Emissions of nitrogen oxides NO
X
mg/kWh 35
(1) Low temperature means 30°C for condensing boilers, 37°C for low temperature boilers and 50°C (at heater inlet) for other heating appli
ances.
(2) High temperature operation means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
See Refer to the back cover for contact details.
3 Technical specifications
14 7625116 - v.04 - 17012017
3.3 Dimensions and connections
Fig.1 Dimensions
AD-0000217-01
110
240
300
42580
226
602 600
143
1045
Flue gas outlet connection; Ø 100 mm Air supply connection; Ø 150 mm Siphon connection
CH flow connection; 1¼ inch male thread CH return connection; 1¼ inch male thread Gas connection; 1 inch male thread
3 Technical specifications
7625116 - v.04 - 17012017 15
3.4 Electrical diagram
Fig.2 Electrical diagram
AD-0000669-05
X01
X02
X03
X04 / X05
X06
X07
X12
X11
X10
X09
X08
Pump
N
L
OT
On/off
0
+
0 - 10
0
+
PWM
BL
RL
Tout
X1
X8
X10
X4X9
X5
X6
X2
X3
X1
1 32
X2
1 32
Pump
N
L
X3
1 32 4 5 6 7 8 9 10 11 12
On/off
OT
PWM
0 +
0 - 10
0 +
Tout
BL RL
X4
1 7-
6.3 AT
F1
X019 X039 X036
X5
1 7-
X6
1 15-
CB-01
X018
X017
X035
X033
X020
230VAC
X038
Bus
X037
Bus
CU-GH & HMI
X12
1 5-
X122X121
X11
1 - 4
X10
1 - 4
X09
1 - 4
X08
1 13-
X083
X07
1 4-
X071
X06
1 4-
X04 / X05
1 15-
X041 X051 X053 X054 X055 X081
X02
1 9-
X03
1 15-
X021X022
X032
X031
X016
X015
X01
1 7-
X0141
X014
230V, 50Hz
X011
X013X012
X20 X202
X201
EMC
20
19
18
17
16
151413121110
9
87
6
5
3 4
2
1
2121
1
Control unit (CU-GH)
2
Lighting
3
Ignition pin
4
Ignition transformer
5
On/off switch
6
Power supply
7
Service connector / computer connection
8
Control panel
9
Fan supply
10
Storage parameter
11
Flow sensor
12
Heat exchanger sensor
13
Return sensor
14
Hydraulic pressure sensor
15
Air pressure differential switch
16
Flue gas sensor
17
Fan control (PWM)
18
Gas valve 1
19
Gas valve 2
20
Standard PCB
21
L-bus connections for additional PCBs
3 Technical specifications
16 7625116 - v.04 - 17012017
4 Description of the product
4.1 General description
The Quinta Ace boiler is a high-efficiency wall-hung gas boiler with the fol lowing properties:
High-efficiency heating. Limited emissions of polluting substances. Ideal choice for cascade configurations.
The following boiler designs are available:
Basic level:
Control panel HMI S-control Control PCB SCB-01
Middle level:
Control panel HMI T-control Control PCB SCB-02
Performance level:
Control panel HMI T-control Control PCB SCB-10
4.2
Operating principle
4.2.1 Gas/air regulation
The boiler is equipped with a casing that also serves as an air box. The fan draws in the combustion air. The gas is injected into the venturi and mixed with the combustion air. The fan speed is controlled on the basis of the settings, the heat demand and the prevailing temperatures measured by the temperature sensors. The gas/air ratio control ensures an accurate mixture of the required amounts of gas and air. This provides optimum combustion over the entire heat input range. The gas/air mixture goes to the burner, where it is ignited by the ignition electrode.
Important The combustion air supply is checked before each burner start, and at least once every 24 hours. During continuous operation (e.g. supplying process water), please note that the boiler control will reset every 24 hours.
4.2.2 Combustion
The burner heats the central heating water flowing through the heat ex changer. If the temperature of the flue gases is lower than the dew point (approx. 55°C), the water vapour condenses in the heat exchanger. The heat released during this condensation process (referred to as the latent or condensation heat) is also transferred to the central heating water. The cooled flue gases are discharged through the flue gas discharge pipe. The condensed water is discharged through a siphon.
4.2.3 Control system
The eSMART® electronic control system ensures that your heating system is smart and reliable. This means that the boiler responds practically to negative environmental influences (such as limited water flow and air flow problems). In the event of such influences, the boiler will not go into lock out mode, but in the first instance will modulate back. Depending on the nature of the circumstances, a warning, control stop or lock-out may occur. The boiler continues to supply heat provided the situation is not danger ous. With this control system, your boiler is also equipped for remote con trol and monitoring.
4 Description of the product
7625116 - v.04 - 17012017 17
4.2.4 Control
On/off control The heat input varies between the minimum and the maximum values on the basis of the flow temperature set on the boiler. It is possible to connect a 2-wire on/off thermostat or a power stealing thermostat to the boiler. Modulating control The heat input varies between the minimum and the maximum values on the basis of the flow temperature determined by the modulating con troller. The boiler output can be modulated with an appropriate modulat ing controller. Analogue control (0 - 10 V) The heat input varies between the minimum and the maximum values on the basis of the voltage present at the analogue input.
4.2.5
Regulating the water temperature
The boiler is fitted with an electronic temperature control with a flow and return temperature sensor. The flow temperature can be adjusted between 20°C and 90°C. The boiler modulates back when the set flow temperature is reached. The switch-off temperature is the set flow temperature + 5°C.
4.2.6
Protection against shortage of water
The boiler is fitted with low water level protection based on temperature measurements. By modulating back when the water flow threatens to be come insufficient, the boiler remains operational as long as possible. The boiler issues a warning in the event of no or too little water. With an insuffi cient flow ΔT ≥ 25 K or too great an increase in the heat exchanger tem perature sensor, the boiler goes into blocking mode.
4.2.7
Water flow
The modulating control of the boiler limits the maximum difference be tween the flow temperature and return temperature. In addition, a heat ex changer temperature sensor is mounted to monitor the minimum water flow. This limits the maximum increase in the heat exchanger temperature and monitors the maximum temperature difference between the flow, re turn and heat exchanger temperatures. As a result, the boiler is not affec ted by low water flow.
4.2.8
Hydraulic pressure sensor
The hydraulic pressure sensor records the water pressure in the boiler. Change the threshold value for the hydraulic pressure sensor using pa
rameter .
4.2.9 Air pressure differential switch
The air pressure differential switch is a protection against a blocked trap or blocked air supply/flue gas outlet.
Before start-up and when the boiler is in operation, the air pressure differ ential switch APS measures the difference in pressure between the meas
uring points on the condensate collector
p+ and the air box p-. If the pres sure difference is greater than 6 mbar, then the boiler will lock out. After eliminating the cause of the breakdown, the boiler can be unlocked.
4 Description of the product
18 7625116 - v.04 - 17012017
4.2.10 Circulating pump
ΔP
Boiler resistance (mbar)
Q
Flow rate (m3/h)
The boiler is supplied without a pump. Take the boiler resistance and sys tem resistance into account when selecting a pump.
See Technical data, page 12.
Caution Maximum power consumption may be 300 VA. Use an auxiliary relay for a pump with greater power.
4.2.11 Calorifier connection
A calorifier can be connected to the boiler. Our range includes various cal orifiers.
Important Contact us for more information.
4.2.12 Cascade system
The boiler is ideally suited for a cascade system. There are a number of standard solutions available.
Important Contact us for more information.
4.3 Main components
1
Air supply/flue gas discharge
2
Casing/air box
3
Interior light
4
Flow sensor
5
Adapter
6
Heat exchanger
7
Temperature sensor for heat exchanger
8
Ignition transformer
9
Inspection hatch for heat exchanger (x2)
10
Water pressure sensor
11
Return sensor
12
PC/laptop connection point
13
Control panel
14
On/off switch
15
Condensate collector
16
Air inlet silencer
17
Gas pressure measuring point
18
Control unit (CU-GH)
19
Gas valve unit
20
Venturi
21
Fan
22
Non-return valve
23
Automatic air vent
24
Flue gas measuring point
4.4
Control panel description
The Quinta Ace boiler is supplied with a separate control panel.
Fig.3
Water resistance
AD-0000857-02
170
300
250
200
150
100
50
0
0 1 2 3 4 5 6 7 8 9 10
6,5
[m3/h]
Q
T = 20 K
Fig.4 Main components
AD-0000218-01
9
8
5
6
7
2
1
4
3
10
12
13
14
11
16
17
18
19
20
21
15
24
23
22
4 Description of the product
7625116 - v.04 - 17012017 19
See Manual for the control panel.
4.5 Standard delivery
The delivery includes 2 packages:
One package with:
The boiler, with mains lead
One package with:
Suspension bracket and fasteners for wall mounting Mounting template Siphon with condensate drain hose Connection box with connector for external connections, including:
Standard control PCB CB-01 Expansion board SCB-01 (depending on boiler model) Expansion board SCB-02 (depending on boiler model)
Expansion board SCB-10 (depending on boiler model) Connection cables (230 V and 24 V) for connection between the con nection box and boiler Sticker: This central heating unit is set for... Documentation Water quality instructions The control panel with a corresponding manual
Important This manual only deals with the standard scope of supply. For the installation or mounting of any accessories delivered with the boil er, refer to the corresponding mounting instructions.
4.6 Accessories and options
Various accessories can be obtained for the boiler.
Important Contact us for more information.
4 Description of the product
20 7625116 - v.04 - 17012017
5 Before installation
5.1 Installation regulations
Warning The installer must be registered with Gas Safe and have the cor rect ACS qualifications.
Important Practical guidelines - see the latest version.
5.2
Lifting instruction
The weight of the boiler exceeds the maximum lift weight for one person. We recommend the use of a lifting aid.
Fig.5
Lifting aids
AD-0000138-03
5.3 Choice of the location
5.3.1 Type plate
The type plate on top of the boiler features the boiler serial number and important boiler specifications, for example the model and unit category. The factory setting codes CN 1 and CN 2 are also stated on the type plate.
Fig.6
Position of type plate
AD-0000103-01
5 Before installation
7625116 - v.04 - 17012017 21
5.3.2 Location of the boiler
Use the guidelines and the required installation space as a basis for de termining the correct place to install the boiler. When determining the correct installation space, take account of the permitted position of the flue gas discharge and/or air supply outlet. Ensure that there is sufficient space around the boiler for good access and ease of maintenance.
Danger It is forbidden to store, even temporarily, combustible products and substances in the boiler or near the boiler.
Caution
Mount the boiler on a strong and solid wall (at least half-brick brickwork with calcium silicate bricks). Build a reinforcing struc ture if necessary. The boiler must be installed in a frost-free area. The boiler must have an earthed electrical connection. A connection to the drain must be present for the condensate drain close to the boiler. The specified minimum space is required for standard mainte nance work. For installation and extensive servicing work, there must be at least 1 m x 1 m of clear space in front of the boiler.
Caution If the power cord is permanently connected, you must always in stall a main bipolar switch with an opening gap of at least 3 mm (BS EN 60335-1).
5.4 Transport
The boiler is delivered on a pallet. The delivery includes 2 packages. One package with the boiler and one package with individual parts and techni cal documentation. See diagram for dimensions. The base of the package is a pallet 80 cm wide. This means that it can be transported with a pallet truck or using four-wheel transport boards. Without the packaging, the boiler is 60 cm wide, meaning it will fit through all standard doorways.
Important Always transport the boiler as close to the mounting plate as pos sible before the packaging is removed.
Fig.7 Installation area
AD-0000104-03
600 3030
min. 1000
60
0
min. 500
min. 300
1045
min. 1000
Fig.8 Boiler package
AD-0000136-02
775
800
1200
5 Before installation
22 7625116 - v.04 - 17012017
5.5 Unpacking & initial preparation
1. Cut the packaging straps and remove.
2. Remove the cardboard box.
3. Take the 2 floor stands out of the packaging and place them on the floor in front of the bottom of the boiler.
4. With 2 people, place the boiler upright on the floor stands.
5. Remove the pallet and the rest of the packaging.
Important The boiler can now be moved with a lifting aid.
Fig.9 Unpacking the boiler
AD-0000137-02
1
1
2
3
4 5
5 Before installation
7625116 - v.04 - 17012017 23
6 Installation
6.1 General
Warning The boiler must be installed by a qualified installer in accordance with local and national regulations.
6.2
Preparation
6.2.1 Positioning the boiler
The fitting bracket on the back of the casing can be used to mount the boiler directly on the suspension bracket.
The boiler is supplied with a mounting template.
1. Attach the mounting template of the boiler to the wall using adhesive tape.
Warning
Use a level to check whether the mounting template is hanging perfectly horizontally. Protect the boiler against building dust and cover the flue gas outlet and air supply connection points. Only remove this cover to assemble the relevant connections.
2. Drill 4 holes of Ø 10 mm.
3. Fit the Ø 10 mm plugs.
4. Attach the suspension bracket to the wall with the Ø 10 mm bolts supplied.
5. Mount the boiler on the suspension bracket at the level of the arrows on the side of the boiler.
Warning
The weight of the boiler exceeds the maximum lift weight for one person. Observe the applicable regulations. We recom mend the use of a lifting aid. Please ensure all necessary care is taken when lifting the boiler on to the wall mounting bracket. The plugs supplied are only suitable for concrete. Select the correct plugs for installation on other materials.
6.3
Hydraulic connections
6.3.1 Rinsing the system
The installation must be cleaned and flushed in accordance with BS 7593 (2006) and BSRIA BG 33/2014.
Before a new CH boiler can be connected to an existing or new installa tion, the entire installation must be thoroughly cleaned and flushed. This step is absolutely crucial. The flushing helps to remove residue from the installation process (weld slag, fixing products etc.) and accumulations of dirt (silt, mud etc.)
Important Flush the CH installation with a volume of water equivalent to at least three times the volume of the CH installation. Flush the DHW pipes with at least 20 times the volume of the pipes.
Fig.10 Mounting the boiler
AD-0000107-01
7
61036
4
7 61036
4
-01
305 143
(
152)
Ø 150 Ø 150
175
300
600
100 100
300
50
50 50
50
185
130
60
110
79.5
79.5
25
1045
(1112)
21.5
46
Ø 10 (2x)
Ø 10 (2x)
25
597
D E T
AI
L SCALE
: 1:2
83.6
218.1
223
233.1
590
1
2
3
4
5
1
2
6 Installation
24 7625116 - v.04 - 17012017
Loading...
+ 56 hidden pages