Regency U39-NG1, U39-LP1 User Manual

www.regency-fi re.com
ULTIMATE U39
Direct Vent Freestanding Gas Stove
Owners &
Installation Manual
MODELS: U39-NG1 Natural Gas U39-LP1 Propane
WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
Tested by:
918-531b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FOR YOUR SAFETY What to do if you smell gas:
Do not try to light any appliance Do not touch any electrical switch:
do not use any phone in your building.
Immediately call your gas supplier
from a neighbour's phone. Follow the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
01/07/08
REGENCY
®
ULTIMATE Direct Vent Freestanding Gas Stove
To the New Owner:
Congratulations! You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace
®
Products International Ltd. The Regency
provide you with all the warmth and charm of a woodstove, at the fl ick of a switch. The models U39-NG1,
and U39-LP1 of this series has been approved by Warnock Hersey for both safety and effi ciency. As it
also bears our own mark, it promises to provide you with economy, comfort and security for many trouble
free years to follow. Please take a moment now to acquaint yourself with these instructions and the many
features of your ULTIMATE Direct Vent Freestanding Gas Stove.
Gas Series of hand crafted appliances has been designed to
®
2
Regency
U39 ULTIMATE Direct Vent Freestanding Gas Stove
TABLE OF CONTENTS
SAFETY LABEL
Copy of Safety Label .....................................................4
REQUIREMENTS
MA Code - CO Detector ................................................5
INSTALLATION
Important Message ........................................................6
Specifi cations ................................................................6
Information For Mobile/Manufactured Homes
After First Sale ...............................................................6
Before You Start ............................................................6
General Safety Information ...........................................7
Installation Checklist ......................................................7
Clearances To Combustibles .........................................7
Manufactured Mobile Home Additional Requirements ..8
Locating your Ultimate Gas Stove ...............................8
Louver Installation .........................................................8
Combustion and Ventilation Air .....................................8
Venting Introduction ......................................................8
Exterior Vent Terminal Locations ................................... 9
4” x 6-5/8” Rigid Pipe Cross Reference Chart .............10
Rigid Pipe Venting Systems ........................................12
Installation Precautions ...............................................13
Rigid Pipe Venting Arrangements ................................13
DV Stove Horizontal Vent Kit Installation ....................15
Dura-Vent Termination Kit ............................................17
Converting a Class-A Metal Chimney or
Masonry Chimney to a Direct Vent System ................21
Gas Connection ...........................................................23
High Elevation .............................................................23
Conversion Kit# 731-969 from NG to LP .....................24
Conversion to Lower BTU Rating ................................27
Gas Pipe Pressure Testing ..........................................27
Aeration Adjustment ....................................................28
Log Set Installation ......................................................29
Wiring Diagram ............................................................32
Optional Wall Thermostat ...........................................33
Optional Remote Control ............................................33
Final Check .................................................................33
OPERATING INSTRUCTIONS
Operating Instructions ................................................34
Shutdown Instructions .................................................34
First Fire ......................................................................34
Lighting Procedure ......................................................34
Automatic Convection Fan Operation .........................35
Normal Operating Sounds of Gas Appliances .............35
MAINTENANCE
Maintenance Instructions ............................................36
General Vent Maintenance ..........................................36
Gold-Plated Doors .......................................................36
Log Replacement ........................................................37
Door Gasket ...............................................................37
Latch Adjustment .........................................................37
Glass Replacement .....................................................37
Fan Maintenance .........................................................38
DC Sparker Battery Replacement ...............................38
Removing Valve ...........................................................39
PARTS LIST
Main Assembly ............................................................40
Burner & Log Assembly ...............................................41
Door Assemblies .........................................................42
WARRANTY
Warranty ......................................................................43
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove
3
SAFETY LABEL
This is a copy of the label that accompanies each ULTIMATE Direct Vent Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety
Copy of Safety Label for U39 Gas Stove
label is located on the inside of the drop down pedestal door.
NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
®
4
Regency
U39 ULTIMATE Direct Vent Freestanding Gas Stove
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove
5
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The ULTIMATE Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.
Note: Failure to follow the instructions
could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage. Failure to follow these instructions may also void your fi re insurance and/or warranty.
Note: These instructions take preced-
ence over Simpson Dura-Vent instructions.
SPECIFICATIONS
Fuels: U39-NG1 is approved for use with
natural gas.
U39-LP1 is approved for use with
liquefi ed petroleum gases (propane).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 125/75.
Log Sets: Ceramic fi bre, 7 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner
liner) rigid fl ue and termination cap.
INFORMATION FOR
MOBILE/
MANUFACTURED
HOMES AFTER
FIRST SALE
This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: CAN/ CGA-2.17-M91 and ANSI Z21.88b-2003/CSA
2.33b-2003.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/ NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This Regency® Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit.
This Regency® Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 ground lug to which an 18 gauge copper wire from the steel
chassis ground must be attached.
This appliance may only be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed
kit is used.
BEFORE YOU START
Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THIS APPLIANCE SHOULD BE INSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
1) Provide adequate clearances for
servicing, proper operation and around the air openings into the combustion chamber.
2) The appliance may be installed on a fl at,
solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or it can be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, tile, wood fl ooring or other combustible material, because the appliance's metal pedestal base extends the full width and depth of the appliance. The ULTIMATE Direct Vent Freestanding Gas Stove can be installed in a wide variety of ways and will fi t nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner.
3) The ULTIMATE Direct Vent Freestanding Gas
Stove is approved for alcove installations, which meet the clearances as listed in the "Locating Your Ultimate Gas Stove" section. This unit is approved for manufactured home installations, see "Rigid Pipe Venting Arrangements" section for the required vent arrangements. If installed into a manufactured home the unit must be bolted down to the fl oor.
®
6
Regency
U39 ULTIMATE Direct Vent Freestanding Gas Stove
INSTALLATION
4) This appliance is Listed for bedroom
installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.
5) This appliance is Listed for Alcove
installations, maintain minimum Alcove clearances as follows, minimum width of 48" (1219mm), a maximum depth of 36" (914mm), and minimum ceiling height of 64"(1626mm).
6) We recommend that you plan your installation
on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualifi ed building inspector review your plans before installation.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform with
local Canadian Electrical Code.
2) The appliance when installed, must be
electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.
3) The appliance should be inspected for shipping damage before use and serviced
annually by a professional service person. More frequent cleaning may be
required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting.
4) See general construction and assembly instructions. The appliance and vent should be enclosed when installed in or passing through a living area, where children may come in contact with it.
5) This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per the instructions starting in "Locating Your Ultimate Gas Stove" section.
6) Inspect the venting system annually for blockage and any signs of deterioration.
7) Venting terminals shall not be recessed into a wall or siding.
8) Any safety glass removed for servicing
must be replaced prior to operating the appliance.
9) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the fi replace.
Emissions from burning wood or gas could contain chemicals known to the State of Cali­fornia to cause cancer, birth defects or other reproductive harm.
INSTALLATION
CHECKLIST
1) Loate your appliance. Refer to the following
sections:
a. Locating Your Ultimate Gas Stove b. Exterior Vent Termination Locations c. Clearance to Combustibles d. Combustion and Ventilation Air
2) Install Louvers. Refer to the "Louver
Installation" section.
3) Choose a venting option and install
accordingly. Refer to the following sections where applicable:
a. DV Stove Horizontal Vent Kit Installation b. Dura-Vent Termination Kit c. Set Vent Restrictors. Refer to "Rigid
Pipe Venting Arrangement" section.
d. Converting a Class-A Metal Chimney
or Masonry Chimney to a Direct Vent system.
4) Make gas connections. Refer to "Gas
Connection" section.
Test the pilot. Must be as per diagram. Refer
to "Pilot Adjustment" section.
5) If necessary, see the "Conversion from NG
to LPG" section and "Conversion to Lower BTU Rating" section.
6) Test Gas Pressure. Refer to "Gas Pipe
Pressure Testing" section .
7) Install standard and optional features.
Refer to the following sections where applicable:
a. Log Set b. Front Door c. Wall Thermostat d. Remote Control
8) Final check. Refer to the "Final Check"
section.
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained
to customer.
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label) after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
CLEARANCES TO
COMBUSTIBLES
The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest
distance is correct if the two clearances do not coincide.
For example, if the appliance is set as indicated in one of the fi gures but the connector is too close, move the stove until the correct clearance to the connector is obtained.
This appliance may be installed only with the clearances as shown in the situations pictured.
Do not combine clearances from one type of installation with another in order to achieve closer clearances.
This unit can be installed on a solid combustible surface like a wood fl oor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit) is installed.
Use the minimum clearances shown in the diagrams below:
U39-NG1 & U39-LP1 Clearances
A Side Wall to Unit 7-1/2" / 190 mm B Back Wall to Unit 6" / 150 mm E Side Wall to Unit 2" / 50 mm
U39-NG1 & U39-LP1 Reference
Dimensions
C Back Wall to Flue Centerline 11"/280 mm D Side Wall to Flue Centerline 20-1/2"/521 mm F Side Wall to Flue Centerline 11"/280 mm Minimum ceiling height is 36" / 914 mm from top of unit.
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove
7
INSTALLATION
Minimum ceiling
height is 36"/914mm
from top of unit.
A) Cross Corner B) Room Divider C) Island D) Flat on Wall E) Flat on Wall Corner F) Flush with Wall/ Alcove
For Vent Termination requirements, see "Exterior Vent termination Locations" section.
LOUVER
INSTALLATION
1) Attach the top & bottom louvers to the
side stove panel using 2 screws per side.
VENTING
INTRODUCTION
The DV Stove Horizontal Vent Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the ULTIMATE Direct Vent Freestanding Gas Stove, U39-NG1, and U39-LP1, have been tested and listed as direct vent heater systems by Warnock Hersey. If converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent system, see instructions in "Converting a Class-A Metal Chimney or Masonry Chimey to a Direct Vent System" section.
These units use the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
Note: These flue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8 ground
lug provided.
3) Appliance must be anchored to the fl oor with
the supplied anchoring methods.
LOCATING YOUR
ULTIMATE GAS STOVE
When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation.
Read all instructions carefully before starting the
IMPORTANT
installation. Failure to follow these instructions may create a fi re or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible requirements. Consult your local building codes before beginning installation.
The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" section.
COMBUSTION AND
VENTILATION AIR
The combustion air from this appliance is drawn from outside the building through the outer fl ue.
Extra provision for combustion air inside the room is not required.
®
8
Regency
U39 ULTIMATE Direct Vent Freestanding Gas Stove
EXTERIOR VENT TERMINAL LOCATIONS
INSTALLATION
with Dura-Vent termination cap (min. 12"/30cm)
horizontally from the centerline of the regulator.
H= Not to be installed above a meter/regulator assembly within (3'/90cm)
air inlet to any other appliance *(12"/30cm)
J= Clearance to service regulator vent outlet *(min. 36"/90cm)
K= Clearance to non-mechanical air supply inlet to building or the combustion
property *(min. 84"/2.1m)
L= Clearance to a mechanical air supply inlet *(min. 72"/1.8m)
M= **Clearance above paved sidewalk or a paved driveway located on public
N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)***
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove
12"/30cm)
A= Clearance above grade, veranda, porch, deck, or balcony *(min.
B= Clearance to window or door that may be opened *(12"/30cm)
horizontal distance of (24"/60cm) from the centerline of the terminal (min.
18"/46cm) check with local code.
C= Clearance to permanently closed window *(min. 12"/30cm)
D= Vertical clearance to ventilated soffi t located above the terminal within a
with Dura-Vent termination cap (min. 12"/30cm)
E= Clearance to unventilated soffi t (min. 12"/30cm)
F= Clearance to outside corner: with AstroCap Termination Cap (min. 6"/15cm),
Note: * As specifi ed in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.
G= Clearance to inside corner: with AstroCap Termination Cap (min. 6"/15cm),
**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
9
INSTALLATION
4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
Description
6” Pipe Length, Galvanized 6” Pipe Length, Black 7” Pipe Length, Galvanized 7” Pipe Length, Black 9” Pipe Length, Galvanized 9” Pipe Length, Black 12” Pipe Length, Galvanized 12” Pipe Length, Black 18” Pipe Length, Galvanized 18” Pipe Length, Black 24” Pipe Length, Galvanized 24” Pipe Length, Black 36” Pipe Length, Galvanized 36” Pipe Length, Black 48” Pipe Length, Galvanized 48” Pipe Length, Black 60” Pipe Length, Galvanized 60” Pipe Length, Black
Adjustable Length 3”-10”, Galvanized Adjustable Length 3”-10”, Black Adjustable Length 11”-14”, Galvanized Adjustable Length 11”-14”, Black Adjustable Length 17”-24”, Galvanized Adjustable Length 17”-24”, Black Adjustable Length 7”, Galvanized Adjustable Length 7”, Black Extension Pipe 8-1/2”, Galvanized Extension Pipe 8-1/2”, Black Adjustable Length 12”, Galvanized Adjustable Length 12”, Black Extension Pipe 16”, Galvanized Extension Pipe 16”, Black
Simpson
Direct Vent Pro
46DVA-06 908 4DT-6 N/A 4D6 SV4L6
46DVA-06B 908B 4DT-6B N/A 4D6B SV4LB6
N/A N/A N/A 4D7 N/A N/A
N/A N/A N/A 4D7B N/A N/A
46DVA-09 907 4DT-9 N/A N/A N/A
46DVA-09B 907B 4DT-9B N/A N/A N/A
46DVA-12 906 4DT-12 4D12 4D12 SV4L12
46DVA-12B 906B 4DT-12B 4D12B 4D12B SV4LB12
46DVA-18 N/A 4DT-18 N/A 4D18 SV4LA
46DVA-18B N/A 4DT-18B N/A 4D18B SV4LA
46DVA-24 904 4DT-24 4D2 4D24 SV4L24
46DVA-24B 904B 4DT-24B 4D2B 4D24B SV4LB24
46DVA-36 903 4DT-36 4D3 4D36 SV4L36
46DVA-36B 903B 4DT-36B 4D3B 4D36B SV4LB36
46DVA-48 902 4DT-48 4D4 4D48 SV4L48
46DVA-48B 902B 4DT-48B 4D4B 4D48B SV4LB48
46DVA-60 N/A N/A N/A N/A N/A
46DVA-60B N/A N/A N/A N/A N/A
N/A N/A N/A N/A 4DAL N/A
N/A N/A N/A N/A 4DALB N/A
Disc - See 46DV-08A N/A 4DT-AJ N/A N/A N/A
Disc - See 46DV-08AB 911B 4DT-AJB N/A N/A N/A
Disc - See 46DV-16A 917 - N/A from FPI N/A N/A N/A N/A
Disc - See 46DV-16AB 917B N/A N/A N/A SV4LBA24
N/A N/A N/A 4D7A N/A N/A
N/A N/A N/A 4D7AB N/A N/A
46DVA-08A N/A N/A N/A N/A N/A
46DVA-08AB N/A N/A N/A N/A N/A
N/A N/A N/A 4D12A N/A SV4LA12
N/A N/A N/A 4D12AB N/A SV4LBA12
46DVA-16A N/A N/A N/A N/A N/A
46DVA-16AB N/A N/A N/A N/A N/A
®
Simpson
Direct Vent GS
Discontinued
®
Selkirk
Direct-Temp™
American Metal
Products
Amerivent Direct
®
Metal-Fab
Sure Seal
®
Security
Secure Vent
®
45º Elbow, Galvanized 45º Elbow, Black 45º Elbow, Swivel, Galvanized
45º Elbow, Swivel, Black
90º Elbow, Galvanized 90º Elbow, Black 90º Elbow, Swivel, Galvanized
90º Elbow, Swivel, Black
90º Starter Elbow, Swivel, Galvanized* Adaptor*
Ceiling Support Cathedral Support Box Wall Support/Band Offset Support Wall Thimble, Black Wall Thimble Support Box/Ceiling Support Firestop Spacer Trim Plate, Black Masonry Chimney Flashing Brass Trim for Wall Thimble/Ceiling Support
10
46DVA-E45 945 4DT-EL45 4D45L N/A N/A
46DVA-E45B 945B 4DT-EL45B 4D45LB N/A N/A
Disc - See 46DVA-E45 945G N/A N/A 4D45L SV4E45 Disc - See 46DVA-
E45B 46DVA-E90 990 4DT-EL90S 4D90LS N/A N/A
46DVA-E90B 990B
Disc - See 46DVA-E90 990G N/A N/A 4D90L SV4E90-1 Disc - See 46DVA-
E90B N/A N/A N/A N/A 4D90A N/A
N/A N/A N/A N/A 4DDA N/A
N/A 949 - N/A from FPI 4DT-CS 4DFSP 4DSP SV4SD
46DVA-CS 941 4DT-CSS 4DRSB 4DRS SV4CSB
46DVA-WS 988 4DT-WS/B 4DWS 4DWS SV4BM
46DVA-ES - N/A from FPI
46DVA-WT 942 4DT-WT 4DWT 4DWT SV4RSM
46DVA-DC N/A N/A N/A N/A SV4PF
46DVA-FS 963 4DT-FS 4DFSP 4DFS SV4BF
N/A N/A 4DT-TP 4DFPB 4DCP SV4LA
N/A N/A N/A N/A N/A N/A
DISC. 3951 N/A N/A N/A N/A
945BG N/A N/A 4D45LB SV4EB45
4DT-EL90SB
990BG N/A N/A 4D90LB SV4EB90-1
989 - N/A from FPI 4DT-OS N/A N/A SV4SU
®
Regency
U39 ULTIMATE Direct Vent Freestanding Gas Stove
4D90LBS N/A SV4EBR90-1
INSTALLATION
4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.)
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
Description
Attic Insulation Shield 12” Attic Insulation Shield - Cold Climates 36”
Simpson
Direct Vent Pro
46DVA-IS - N/A from FPI
N/A N/A N/A 4DAIS36 N/A N/A
®
Simpson
Direct Vent GS
Discontinued
N/A N/A 4DAIS12 N/A SV4RSA
®
Selkirk
Direct-Temp™
American Metal
Products
Amerivent Direct
®
Metal-Fab
Sure Seal
®
Security
Secure Vent
®
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap High Wind Horizontal Cap Horizontal Square Termination Cap Vertical Termination Cap Storm Collar
Adjustable Flashing, 0/12-6/12 Adjustable Flashing, 6/12-12/12
Vinyl Siding Standoff Vinyl Siding Shield Plate
Snorkel Termination 14” Snorkel Termination 36”
Restrictor Disk Extended Vertical Termination Cap Chimney Conversion Kit A Chimney Conversion Kit B Chimney Conversion Kit C Chimney Conversion Kit Masonry Mansonry Chimney Conversion Kit
(includes: Cap Adapter 18”x18” Flashing)
Wall Firestop Colinear Flex Connectors
FPI
946-506/P Vent Guard (Optional) for AstropCap 946-205 Vinyl Siding Shield for Riser Vent Terminal
510-994 Rigid Pipe Adapter (Must use with all Rigid Piping) 946-208/P Vent Guard (Optional) for Riser Vent Terminal
640-530/P Riser Vent Terminal 946-523/P AstroCap Horizontal Cap
DISC. 970 4DT-HKA 4DHTK2 4DHTKA SV - SHK 46DVA-KHA
(Changed Components) DISC. 978 4DT-VKC 4DVTK 4DVTK SV - FK
46DVA-VCH 991 N/A N/A N/A N/A
46DVA-HC 985 N/A N/A N/A N/A
Disc - See 46DVA-HC 984 4DT-HHC 4DHC 4DHT SV4CHC-1
46DVA-VC 980 4DT-HVC 4DVC 4DVT SV4CGV-1
46DVA-SC 953 4DT-SC 4DSC 4DSC SV4FC
46DVA-F6 943 4DT-AF6 4DF 4DF SV4FA
46DVA-F12 943S 4DT-AF12 4DF12 4DF-12 SV4FB
46DVA-VSS 950 4DT-VS N/A 4DVS SV4VS
N/A N/A 4DT-VSP N/A N/A SV4VS
46DVA-SNK14 982 4DT-ST14 4D12S 4DST14 SV4STC14
N/A 981 4DT-ST36 4D36S 4DST36 SV4STC36
46DVA-RD 929 N/A N/A N/A N/A
46DVA-VCE 930 N/A N/A N/A N/A
46DVA-KCA 931 N/A N/A N/A N/A
46DVA-KCB 932 N/A N/A N/A N/A
46DVA-KCC 933 N/A N/A N/A N/A
46DVA-KMC 934 N/A N/A N/A N/A
46DVA-KCT 935 N/A N/A N/A N/A
46DVA-WFS 947 N/A N/A N/A N/A
46DVA-ADF 923F N/A N/A N/A N/A
971 4DT-HKB 4DHTK1 4DHTKB SV - HK
946-206 Vinyl Siding Standoff for AstroCap
*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (4DDA) or 90º Starter Elbow (4D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection:
Use this table to determine offset pipe lengths.
Pipe Length
0”(0mm) 4-7/8”(124mm) 13-3/8”(340mm)
6”(152mm) 8”(203mm) 16-1/2”(419mm)
9”(229mm) 10-1/8”(257mm) 18-5/8”(473mm)
12”(305mm) 12-1/4”(311mm) 20-3/4”(527mm)
24”(610mm) 20-5/8”(524mm) 29-1/8”(740mm)
36”(914mm) 29”(737mm) 37-1/2”(953mm)
48”(1219mm) 37-7/16”(951mm) 45-15/16”(1167mm)
NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present a possible fi re hazard.
4” x 6-5/8” Venting
Run (X) Rise (Y)
L
Y
X
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove
For specifi c instructions or details on particular venting components please visit the following websites:
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products Amerivent Direct:
www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
11
INSTALLATION
Alternate Horizontal Ter­mination Caps
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
WARNING:
Do not combine venting components from different venting systems.
However use of the the AstroCapTM and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS, Selkirk Direct-Temp, Ameri Vent Direct venting and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.
The FPI AstroCap American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent GS,
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
12
Regency
®
U39 ULTIMATE Direct Vent Freestanding Gas Stove
INSTALLATION
INSTALLATION
PRECAUTIONS
These venting systems are engineered products that have been designed and tested for use with the U39-NG1, and U39-LP1. The warranty will be voided and serious fi re, health or other safety hazards may result from any of the following actions:
1) Installation of any damaged Direct Vent
component
2) Unauthorized modifi cation of the Direct
Vent System
3) Installation of any component part not
manufactured or approved by Simpson Dura-Vent or Fireplace Products International Ltd.
4) Installation other than as instructed
by Simpson Dura-Vent and Fireplace Products International Ltd.
Warning: Always maintain required clearances (air spaces) to nearby combustibles to prevent a fi re hazard. Do not fi ll air spaces with insulation.
RIGID PIPE VENTING ARRANGEMENTS
Horizontal Terminations for All
Venting Systems
The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations. Maximum one 90O elbow (two 45o elbows equal one 90o elbow).
Propane and Natural Gas:
Residential, Manufactured and
Mobile Homes Installations
The venting arrangements diagrammed below, have a min. of 75% (fl ue loss) effi ciency with Fan Off, as required for manufactured homes. (Actual effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile)
Homes after fi rst sale.
Vertical Termination Systems for
Residential Manufactured and
Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum two 45o elbows.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile)
Homes after fi rst sale.
Be sure to check the vent termination clearance requirements from decks, windows, soffi ts, gas regulators, air supply inlets and public walkways as specifi ed in the "Exterior Vent Terminal Locations" section in your local building codes.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each
direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
SAFETY
PRECAUTIONS FOR
THE INSTALLER
1) Wear gloves and safety glasses for
protection.
2) Exercise extreme caution when using
ladders or on roof tops.
3) Be aware of electrical wiring locations
in walls and ceilings.
To set the Vent restriction as indicated in the diagram, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws.
Vent Restrictor Position
Vent Restrictor setting at
38,000 Btu/h
Vent Restrictor setting at
30,000 Btu/h
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove
13
INSTALLATION
Horizontal Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V H + H1
A) 3' Min. 2' Max. B) 5' Min. 3' Max. C) 8' Min. 4' Max.
With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 4 feet total horizontal.
Please note minimum 1 foot between 90o elbows is required.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), Refer to the "Venting Ar­rangement" section.
Vertical Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V H V1 V + V1 A) 1' Min. 1' Max. 1' Min. 2' Min. B) 1' Min. 2' Max. 2' Min. 3' Min. C) 2' Min. 3' Max. 2' Min. 4' Min. D) 2' Min. 4' Max. 2' Min. 4' Min.
With these options, max. total pipe length is 30 feet with min. of 4 feet total vertical and max. 4 feet total horizontal.
Please note min. 1 foot between 90 required.
Lengths do not include elbow indicated
Vent restrictor position A (fully open). Refer to the "Venting Arrangement" section.
o
elbows is
14
Regency
®
U39 ULTIMATE Direct Vent Freestanding Gas Stove