aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
Gas Inserts
U32 Regency Gas Insert
U32 Regency Gas Insert
Model U32-NG5 U32-LP5
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (2.99 kPa)
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifi ce Size -Altitude 0-4500 ft. #37 DMS #52 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing 3” Co-linear 3” Co-linear
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
15,300 BTU/h
(4.48 kW)
30,000 BTU/h
(8.79 kW)
A
15,000 BTU/h
(4.40 kW)
30,000 BTU/h
(8.79 kW)
Gas Inserts
B
C
G
F
D
H
I
E
Dimension Description U32
A Faceplate Width 40-1/4” (1022mm)
B Faceplate Height 26-1/4” (667mm)
C Unit Width 28” (711mm)
D Unit Height 20” (508mm)
E Unit Depth 13-3/4” (349mm)
F Faceplate to Vent Centerline 10-3/4” (273mm)
G Faceplate Depth 1-3/8” (35mm)
H Height to Vent Collar 21-1/16” (535mm)
I Optional or Standard Front Depth 3-3/4” (95mm)
Minimum Fireplace Dimensions
The minimum fi replace dimensions for the FPI gas fi replace insert are
shown in the following diagrams:
M
J
Dimension Description
J Height 22” (559mm) 22” (559mm)
K Width 26-1/2” (673mm) 29” (737mm)
L Depth 14” (356mm) 15” (381mm)
M Max. Lintel Bar Depth 9” (229mm) 10” (254mm)
N Rear Width 22-1/2” (572mm) 22-1/2” (572mm)
L
aaaaaaaa
aaaaaaaa
K
aaaaaaaa
aaaaaaaa
aaaaaaaa
N
Contour
Faceplate
Molded
Faceplate
125August 2008 Product Specifi cations Book
U32 Regency Gas Insert
Clearances
Gas Inserts
Combustible Mantels
Unless otherwise stated the clearances listed below are Minimum
distances to combustible materials. Please Note: A major cause
of chimney related fi res is due to a failure to maintain required
clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in
accordance with these instructions.
Clearances to Combustibles
Dimension Description U32
A From Unit to Sides 10” (254mm)
Gas Inserts
B From Unit to Ceiling 47.5” (1207mm)
C From Unit to Mantel see diagram 2 & 3
D From Standard Surround to Sides 4” (102mm)
E From Standard Surround to Ceiling
G Maximum Mantel Depth
H Minimum Alcove Width 48” (1219mm)
I Maximum Alcove Depth 36” (914mm)
* No Hearth Required
E
41.5” (1054mm)
also see diagram 2 & 3
12” (305mm)
see diagram 2
B
Because of the extreme heat this fi replace emits, the mantel
clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.
A
D
C
Mantle
Faceplate
12" Max.
G
G
H
C
Combustible
Flooring
I
Note: A non-combustible mantel may be installed at a lower
height.
Note: Ensure the paint that is used on the mantel and the facing
is “heat resistant” or the paint may discolour.
Flush
with
Floor
126 August 2008 Product Specifi cations Book