LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certifi ed by the Australian Gas
Association for installation and operation as
described in these Installation and Operating
Instructions.
Your unit should be serviced annually by
an authorised service person.
Models: IG34-NG
IG34-LPG
IG34-ULPG
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE
REFERENCE
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional information consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your
gas supplier, call the fi re
department.
918-793a
04/28/09
REGENCY
GAS INBUILT FIREPLACE
TO THE NEW OWNER
Congratulations! Y ou are the owner of a state-of-the-art Gas Inbuilt Fireplace by FPI. The Regency
Gas Fireplace Series of appliances has been designed to provide you with all the warmth and
charm of a fi replace, at the fl ick of a switch. The model IG34 of this series has been approved
by Australian Gas Association for both safety and effi ciency. As it also bears our own mark, it
promises to provide you with economy, comfort and security for many trouble free years to follow.
Please take a moment now to acquaint yourself with these instructions and the many features of
your Regency Fireplace.
UNIT DIMENSIONS
2
Regency IG34 Gas Inbuilt Fireplace
TABLE OF CONTENTS
DATA BADGE
Copy of Data Badge .....................................................4
INSTALLATION
Important Message ........................................................5
For Your Safety ..............................................................5
Before You Start ............................................................5
This is a copy of the label that accompanies each Regency IG34 Gas
Inbuilt fi replace. We have printed a copy of the contents here for your
review.
DATA BADGE NOTE: Regency units are constantly being improved.
Check the label on the unit and if there is a difference, the label on the
unit is the correct one.
Regency Gas Fireplace
Model
Gas TypeNGLPGULPG
Model
Gas Consumption31.7 .30.626.4
Manifold Pressure0.87
Injector Size1x1x#521x#53
AGA Approval 7469
Code AS4553 NZS 5262
Electrical: 240VAC 50Hz 1.0 amp
918-794
IG34-NGIG34-LPGIG34-ULPG
mjmj.mj.
kPakPakPa
37
#
2.512.51
2.64mm1.61mm1.51mm
N2134
Distributed by:
Western Australia:
Eastern Australia:
accordance with installation instructions provided
Serial
Number
Air Group Australia
28 Division St
Welshpool WA 6106
Fireplace Products
Australia Pty. Ltd.
21-23 South Link Blvd.
Dandenong, VIC 3175
To be installed by an authorised person in
with the appliance.
347
(Australia Only)
4
Regency IG34 Gas Inbuilt Fireplace
INSTALLATION
IMPORTANT MESSAGE
The Regency Gas Inbuilt must be installed in
accordance with these instructions. Carefully
read all the instructions in this manual fi rst.
Note: Failure to follow these instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or property damage. Failure to follow these
instructions may also void your fi re
insurance and/or warranty.
FOR YOUR SAFETY
This appliance requires air for proper combustion. Always provide adequate combustion
and ventilation air. Follow instructions and
information in the current AS5601, NZS 5262
or local codes. Consult the "authority having
jurisdiction" to determine the need for a permit
prior to starting the installation.
MATERIALS REQUIRED
A 240 Volt AC power cord is hooked up to the
unit. Plug 3 wire cord into a suitable receptacle.
Do not cut the ground terminal off under any
circumstances.
When connected with 240 volts, the appliance
must be electrically grounded in accordance
with local codes.
This unit is polarity sensitive and will not
operate if polarity is incorrect.
BEFORE YOU ST ART
Installation is to be carried out ONLY by an
authorised person.
1) The appliance shall be installed in accord-
ance with the manufacturer's installation
instructions, local gas fi tting regulations,
municipal building codes, water supply
regulations, electrical wiring regulations,
with AS5601. (AGA gas installation code)
NZS 5262(New Zealand)
2) Installation and repair should be done
ONLY by an authorised person.
3) The appliance should be inspected before
use and at least annually by an authorised
service person. More frequent cleaning may
be required due to excessive lint from carpeting, bedding material, etc. It is imperative
that control compartments, burners and
circulating air passageways of the appliance
be kept clean and free from excessive lint
from carpeting.
4) See general construction and assembly
instructions. This appliance may only be installed in a fl ued, non-combustible fi replace.
The appliance and fl ue should be enclosed
when installed or passing through a living
area, where children may come in contact
with it.
5) Always connect this space heater to a chimney and fl ue to the outside of the building
envelope. Never fl ue to another room. Make
sure that the fl ue is properly sized and is
of adequate height to provide the proper
draft.
6) Inspect the fl ueing system annually for
blockage and any signs of deterioration.
7) Any safety glass removed for servicing
must be replaced prior to operating the appliance.
INSTALLATION
CHECKLIST
Before installing vent system ensure that the
damper plate is open and secure to prevent the
damper plate from falling down and crushing
the liner.
The FPI Gas Inbuilt is installed as listed.
1) Check all clearances to combustibles, (Refer
to sections "Minimum Fireplace Dimensions
and Clearances to Combustibles)
2) Make the gas connection. (Refer to section
"Gas Connection")
3) Install the 3" (76.2mm) fl ue liner to the sliding
connector plate. (Refer to section "Flue Liner
Installation.")
4) Slide the unit half way into the fi replace.
5) Pull the vent connector plate through the
tapered brackets and fasten to the front plate.
Refer to section "Flue Liner Installation.")
6) Slide the unit fully into the fi replace.
7) Test gas pressure (Refer to section "Gas
Pipe Pressure Testing"). Check aeration
system (Refer to section "Gas Insert Aeration
System").
8) Install standard and optional features. Refer
to the following sections:
a. Log Set
b. Faceplate & Door Trim
c. Inner Stainless Panels
9)Final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is fi ring correctly. This includes:
a) Clocking the appliance to ensure the
correct fi ring rate.
WARNING:
Suitable for installation into a masonry
fi replace only.
Regency IG34 Gas Inbuilt Fireplace
8) T o prevent injury , do not allow anyone who
is unfamiliar with the operation to use the
fi replace.
9) Installer must mechanically attach the supplied label to the inside of the fi rebox of the fi replace into which the gas fi replace insert
is installed.
"WARNING: This fi replace has been converted
for use with a gas fi replace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the fi replace re-approved by the authority
having jurisdiction."
b) Adjusting the primary air and restrictor
settings, if required, to ensure that the
fl ame does not carbon.
NOTE:
TO BE INSTALLED ON A
NON- COMBUSTIBLE FLOOR.
5
INSTALLATION
MINIMUM FIREPLACE
DIMENSIONS
The minimum fi replace dimensions for the
Regency gas space heater are shown in the
following diagrams:
CLEARANCES TO
COMBUSTIBLES
Minimum Clearances to Combustibles
From Unit
Sides A 10" / 255mm
Ceiling B 47.5" / 1205mm
Mantel C 13" / 330mm
Max. Mantle Depth E 12" / 305mm
(see Dia. 2)
Min. Alcove Width F 48" / 1220 mm
Max. Alcove Depth G 36" / 915 mm
*No hearth required.
Mantel Clearances
Note: A non-combustible mantel may be
installed at a lower height if the framing is made of metal studs covered
with a non-combustible board.
GAS CONNECTION
GAS CONNECTION WARNING:
Only persons licensed to work
with gas piping may make the
necessary gas connections
to this appliance.
1) If the appliance is to be installed into an
existing chimney system, thoroughly clean
the masonry fi replace.
2) The appliance is provided with an opening
on the right hand side of the control
compartment. The 9.5mm (3/8") fl exible
gas hose provided needs to be brought in
from behind this opening. Ensure all gas
connections are tight.
3) Locate the center point where the vent
will pass through the chimney above the
appliance. Move the appliance into the
exact location where it is to be installed.
Ensure that the Insert is level.
FLUEING
THE APPLIANCE MUST NOT
BE CONNECTED TO A
CHIMNEY FLUE SERVING A
SEPARATE SOLID FUEL
BURNING APPLIANCE AND
MUST BE TERMINATED TO
THE OUTDOORS.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. The fl ue length
must be a minimum length of 8 ' (2.44m) and
a maximum of 35' (10.7m). See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.
Masonry chimneys may take various contours
which the fl exible liner will accommodate.
However, keep the fl exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet
air collar of the termination cap.
Part # Description
948-305 76mm Flex - 10.6m
46dva-gk Simpson Duravent Adaptor
46dva-vch Simpson Vertical high wind cap
C
L
6
Note: When installing the fl ueing, identify
the fl ues.
Mark one exhaust and one intake as
indicated on the top of the unit.
Gas
Inlet
Regency IG34 Gas Inbuilt Fireplace
INSTALLATION
The Air Intake pipe must be attached to the
inlet air collar of the termination cap.
FLUE LINER
INSTALLATION
1) Cut the fl ex liner as required.
2) Mark the end of one liner to indicate
Inlet.
3) Connect the other end of the above liner to
the inlet side of the termination adaptor, seal
connection with high temperature silicone.
Secure with gear clamp.
4) Connect the 2nd liner to the exhaust side
of the adaptor, seal connection with high
temperature silicone. Secure with gear
clamp.
Be careful not to damage thermal insula-
tion when sliding on vent connector plate.
This could cause blockage.
9) Connect the 2nd liner to the exhaust collar
marked with an "E", seal connection with
high temperature silicone. Secure with gear
clamp.
4) Seal and or check the pilot outlet (# 8)
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits specifi ed on the safety
label.
6) When fi nished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8"
fl at screwdriver. Screw should be snug,
but do not over tighten.
S.I.T. Valve Description
1) On-Off Solenoid Valve EV1
2) On-Off Solenoid Valve EV2
3) Inlet Pressure Test Point
4) Outlet Pressure Test Point
5) Connection for Pressure Regulator/
Combustion Chamber Compensation
6) Pressure Regulator for Minimum and
Maximum Outlet Pressure
7) Gas Outlet Pressure Electric Modulator
8) Pilot Outlet
9) Main Gas Outlet
10) Side Outlet
5) Install fl ashing.
6) Insert both liners into chimney, passing
through the damper opening.
7) Install termination cap.
8) Connect the marked end of the liner to the inlet
collar of the vent connector plate marked with
an "I", seal connection with high temperature
silicone. Secure with gear clamp.
Install to AS5601 (Australia) /
NZS 5262 (New Zealand)
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
(3.45 kPa). Disconnect piping from valve at
pressures over 3.45 kPa (14" w.c.).
The manifold pressure is controlled by a
regulator built into the gas control, and should
be checked at the pressure test point.
Note: To properly check gas pressure,
both inlet and manifold pressures
should be checked using the valve
pressure ports on the valve.
1) Make sure the valve is in the "OFF"
position.
2) Loosen the "IN" (# 3) and/or "OUT" (# 4)
pressure tap(s), turning counterclockwise
with a 1/8" wide fl at screwdriver.
3) Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" (8mm) ID
hose.
Regency IG34 Gas Inbuilt Fireplace
7
INSTALLATION
INSTALLATION IN MASONRY OR ZERO CLEARANCE CHIMNEY
1) Measure and record dimensions to determine total
Flex Liner length requirements (see instructions below
for details).
2) Carefully feed the liner down the chimney (masonry
or zero clearance) and out through the damper. One
person should feed the liner through the chimney, and
another person should pull the liner from the bottom.
3) After carefully feeding the Flex Liner down the chimney to the bottom, form and angle to line up the Flex
Liner with the vent opening on the appliance.
Important: Do not let the Flex Liner sag below the level
at which it will connect to the appliance or connector.
This could allow hot gas to become trapped and potentially become a fi re hazard. The Flex Liner path should
always be sloped up toward the Termination Cap.
4) Temporarily secure the Flex Liner at the top of the
chimney. Be sure to leave 2-3 inches of fl ex above the
existing chimney to allow for connection to the Termination Kit (Baseplate and Adaptor).
Flex
Liners
51-76mm
Existing
Chimney
Note: If you are planning to extend the height of the
chimney using Direct Vent GS Pipe, please refer to the
Direct Vent Installation Instructions for information concerning the proper procedure and restrictions of Direct
Vent Pipe.
Also, consult the appliance manufacturer for any height
restrictions of the chimney.
9) Connect the Co-Linear Flex to the two outlets on the
top of the appliance using four sheet metal screws each.
See the appliance manufacturer's instructions for details. Make sure the Flex Liners do not sag behind the
appliance. Finally, move the appliance into its appropriate place. Mount the Adaptor to the Baseplate using
sheet metal screws.
5) Repeat Steps 1-4 for second length of Flex Liner.
6) At the top of the chimney, slide the Baseplate over
the tow ends of the Flex Liner and secure it to the surrounding masonry using masonry anchor bolts. Before
installing the baseplate, run a bead of non-hardening
seal and between the Baseplate and the masonry to
prevent moisture from entering the chimney.
Note: Verify that there is suffi cient room to mount the
Baseplate on to the masonry. You must have a level
surface in order to install the Baseplate properly.
7) Attach the Flex Liner ends at the top of the chimney
to the Co-Linear to Co-Axial Adaptor. Use four sheet
metal screws to connect each Flex Liner run to the
Adaptor.
8) Twist lock the Vertical Termination Cap to the Adaptor.
8
Regency IG34 Gas Inbuilt Fireplace
System Data
IG34
IG34-NG: For 0 to 610 meters altitude
IG34-LPG: For 0 to 610 meters altitude
IG34-ULPG: For 0 to 610 meters altitude
Burner Inlet Orifi ce Sizes:
NG LPG ULPG
Burner #37 #52 #53
Electrical: 240 V. 50Hz.
Circulation: High/Off/LO speed fan,
150/89 CFM.
Log Set: Ceramic fi ber, 7 per set.
Aeration Setting
NG 13mm open
LPG 13mm open
ULPG 13mm open
AERATION SETTINGS
The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. This adjustment is performed by
the installer. (Close the aeration for a more yellow fl ame, or open it to make the fl ame bluer).
NG: 13mm open
LPG: 13mm open
ULPG: 13mm open
Note: Any damage due to carboning resulting from improperly setting the aeration and restrictor setting controls is NOT covered
under warranty.
Regency IG34 Gas Inbuilt Fireplace
9
INSTALLATION
Conversion Kit #486-968 for NG to LPG Model
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
onversion Kit 486-968 Contains:
9) Pull out the pilot hood by hand.
12) Replace the yellow "NG" label with
the red "ULPG" label.
ty. Part # Description
1 904-345 Burner Orifi ce #51
1 918-273 Red "LPG" label
1 918-272 Label "Converted to LPG"
1 910-037 LPG Pilot Injector
1 918-823 Instruction Sheet
) Shut off the gas supply and unplug
the power cord.
) Remove the glass door, logs and
lava rock.
) Remove the rear log tray by remov-
ing the 2 screws. (Log tray must be
rotated to clear the burner.)
) Remove the grate.
) Remove the burner and ensure the
aeration setting is 13 mm open.
) Remove burner orifi ce with a 1/2"
wrench and discard. Use a wrench
to hold on to the elbow behind the
orifi ce.
Pilot
Hood
Pilot
Hood
removed
Pilot
Orifi ce
10) Remove the pilot orifi ce with the
allen key.
13) Carefully pull out the control box.
NOTE: The control box is held in
place with velcro.
14) Remove the heat shield from the
control box by removing the 2
screws.
15) Remove the control box cover by
undoing the 3 screws.
Manoeuvre through antenna.
Antenna
Control Box
Cover
16) Remove the jumper using a plier.
Burner
) Reinstall new burner orifi ce LPG
stamped #51 and tighten.
) Apply the conversion label "This
unit has been converted to ULPG"
over top of the serial number decal.
Note: Aeration settings do not need
to be adjusted.
10
11) Put in the new LPG orifi ce with the
allen key. Then put back the pilot
hood.
Jumper Location
Jumper
17) Reverse steps 13, 12, 11, 6, 5, 4, 3
& 2.
Regency IG34 Gas Inbuilt Fireplace