REFCO REF-METER-OCTA User Manual [en, de, es, fr, it]

0 (0)

REF-METER-OCTA 4679462

Instruction Manual

Electronic Charging scale

Bedienungsanleitung

Elektronische Füllwaage

Mode d’emploi

Appareil de charge électronique

Istruzioni per l’uso

Bilancia elettrica

Manual de instrucciones

Báscula eléctrica

English

REF-METER-OCTA User’s Guide

Introduction

Thank you for your purchase of the REF-METER-OCTA Digital Charging Scale. The REF- METER-OCTA is the most accurate and precise refrigerant meter available today with features that cannot be found anywhere else. It is ideal for HVAC and Refrigeration service, including Critical Charging of small refrigeration systems.

With the REF-METER-OCTA, you can measure weight in both kgs and lbs units. The REF- METER-OCTA is programmable, and has a built in alarm to indicate a programmed threshold has been exceeded. Attaching the REF-METER-OCTA to the REF-METER- OCTA-PLUS allows automatic refrigerant charging for A/C systems.

Features

Large, high-visibility LCD display

Measures weight in kgs, lbs and oz

Built-in memory remembers all previous settings

Refrigerant Tank Capacity Indicator

Rugged, Compact Design

Long Battery Life

High Accuracy and Resolution

Programmable

Can be calibrated in the field with inexpensive reference weights

Thread for mounting 10612-REF for liquid filling and charging of refrigerants cans

Expandable with REF-METER-OCTA-PLUS

Specifications

 

Capacity

100 kilograms (220 Pounds)

Accuracy

0.5% of Reading +/- 1 Least Significant Digit

Resolution

2g, 0.005 lbs., 0.1 oz.

Power

4 x 1.5V ‘AAA’ Alkaline Batteries

Battery Life

30 hours continuous use

Operating Temperature

10C – 40C (50F – 104F)

Weight

3.8 kg (6.4 lbs.)

Dimensions

30.5 cm x 30.5 cm x 4.5 cm (12.0” x 12.0” x 1.8”)

NOTE: To prevent damage, never exceed the rated capacity of the REF-METER-OCTA.

1

REF-METER-OCTA User’s Guide

English

Parts Diagram

10612-REF (optional)

Thread to mount 10612-REF

Weighing

Platform

Button for Cable auto reel

Mounting

Clip

Speaker

Grill

Battery

Cover

Refrigerant Can (optional)

LCD Display

Keypad

Storage Dock

Optical Port for REFMETER- OCTA-PLUS

Control Box Rear View

2

English REF-METER-OCTA User’s Guide

LCD Display

 

 

A

B

 

 

C

E

 

 

 

F

 

 

D

 

 

 

G

 

 

 

H

 

 

 

I

J

K L M N O

P

Item

Function

A

Main Numeric Display

B

Alternate Numeric Display

C

Tank Capacity Percent Indication

D

Units Indicators

E

Sound Mute Indicator

F

“Floating” Negative Indicator (Indicates weight removed from platform)

G

Battery Level Indicator

H

Fast Adjustment Indicator

I

Set Mode Indicator

J

Tank Capacity Mode Indicator

K

Run Mode Indicator

L

Hold Mode Indicator

M

Program Complete Indicator

N

Calibration Mode Indicator

O

Valve Open/Closed Indicator for use with REF-METER-OCTA-PLUS

P

Resolution Indicator

3

REF-METER-OCTA User’s Guide

English

Keypad

Press for power-on, press/hold for power off.

Press to cycle through displayed units.

Press to select low, medium, or high display resolution.

Press to “zero-out” current reading on display.

Use to adjust various settings and programming values/Backlight.

For faster adjustments. Used in conjunction with and . “Freezes” display.

Starts programming mode

Activates / Deactivates stored program.

4

English

REF-METER-OCTA User’s Guide

Quick Start

To operate the REF-METER-OCTA as a basic weigh scale, perform the following steps:

Setup

1.Unpack the scale as described in the “Unpacking the REF-METER-OCTA” section below.

2.Install the batteries into the control box as described in the “Battery Installation” section below.

3.Place the Weighing Platform on a firm, level surface.

4.Turn the REF-METER-OCTA on by pressing .

5.Select the proper measurement units by repeated pressing . The units will cycle as follows:

kilograms Ö pounds Ö pounds and ounces Ö ounces

6.Select the desired display resolution by repeatedly pressing as described in the RESOLUTION section.

Basic Weighing Operation

1.If using a container to hold the objects being measured, place it empty on the center of the platform.

2.Press to “zero-out” the scale. The display will read zero.

3.Place the material to measure in the container or on the center of the platform.

4.Read the weight on the display.

5.A positive number indicates the applied weight is greater than the zero value. A negative number indicates the applied weight is less than the zero value.

6.Turn the REF-METER-OCTA off by pressing down.

7.To conserve battery life, the REF-METER-OCTA will turn itself off after 30 minutes of inactivity, unless it is currently running a program (see Programming section). The last state of the REF-METER-OCTA will be restored upon power-up.

5

REF-METER-OCTA User’s Guide

English

Unpacking the REF-METER-OCTA

1.Remove the REF-METER-OCTA from the carry bag.

2.Push the signed part of the control box to remove it from the storage dock. The storage dock is placed on the low side of the weighing platform.

3.Pull out the control box from the storage dock. When using the REF-METER-OCTA, ensure the cable does not touch the top of the weighing platform to avoid inaccuracies.

4.If desired, extend the mounting hook.

Repacking the REF-METER-OCTA

1.If extended, restore the easel of the control box to the retracted position.

2.Hold the control box and press the yellow auto reel button on the side of the platform.

3.Push the control box firmly into the storage dock of the weighing platform until it snaps in place.

4.Replace the REF-METER-OCTA into the carry bag.

Battery Installation & Replacement

1.Remove the battery cover from the rear of the control box by compressing tab at the base of the battery cover.

2.If necessary, remove old set of batteries.

3.Insert 4 ‘AAA’. Replace battery cover by aligning tabs and snapping back into place.

IMPORTANT: TO PREVENT DAMAGE TO THE REF-METER-OCTA, CAREFULLY OBSERVE BATTERY POLARITY AS MARKED INSIDE THE BATTERY COMPARTMENT. DO NOT LEAVE DEAD BATTERIES INSIDE THE CONTROL BOX. REMOVE BATTERIES IF THE REF-METER-OCTA IS NOT TO BE USED FOR AN EXTENDED PERIOD OF TIME.

6

English

REF-METER-OCTA User’s Guide

Resolution

The resolution (minimum incremental weight or volume) that can be displayed by the REF- METER-OCTA can be adjusted to make the display easier to read. Unstable loads or high winds can cause the display to fluctuate erratically. By reducing the display resolution, external influences can be minimized. As shipped, the REF-METER-OCTA is set to MEDIUM resolution, suitable for most purposes. The resolution can be changed to LOW,

MEDIUM or HIGH by repeated pressing on the keypad. Table 1 illustrates the displayed resolution for each units mode vs. resolution. Regardless of the resolution setting, the scale operates internally with the highest resolution; therefore, only the displayed value is affected.

 

 

Units

 

 

 

 

Pounds

 

 

 

 

&

 

Resolution

Kilograms

Pounds

Ounces

Ounces

 

 

 

 

 

HIGH

2 g

0.005

0.1 oz.

0.1 oz.

lbs

 

 

 

 

 

 

 

 

 

MEDIUM

5 g

0.010

0.2 oz.

0.2 oz.

lbs.

 

 

 

 

 

 

 

 

 

LOW

10 g

0.020

0.5 oz.

0.5 oz.

lbs.

 

 

 

 

TABLE 1.

Resolution Settings

 

 

7

REF-METER-OCTA User’s Guide

English

Over Range Indication

If the weight applied to the weighing platform exceeds the maximum capacity of the REF- METER-OCTA (100 kg), a single “1” will be shown on the left side of the display. To prevent damage to the REF-METER-OCTA, immediately remove the weight from the platform.

Hold Mode

A special feature of the REF-METER-OCTA allows the emptying or replacing bins or containers used for weighing without affecting the weight shown on the display. This Hold Mode may be used as follows:

1.Allow load to settle until display is steady.

2.Press . The current weight is now locked on the display.

3.Remove, empty, or replace objects, bins, or containers on the platform.

4.Wait 5 seconds for the new load to stabilize.

5.Press . Measurements will continue from where they left off prior to initiating Hold Mode.

Programming

With the REF-METER-OCTA, a programmable threshold weight will sound an alarm. The alarm will sound when the displayed weight (either positive for increasing weight, or negative for decreasing weight) equals the programmed weight. To program the alarm, perform the following steps:

1.Set up the REF-METER-OCTA with the desired units and resolution as described in the Quick Start Setup section above.

2.If measuring decreasing weight, place the objects or container with the objects or material that will be removed on the weighing platform.

3.Press to start the SET Mode, indicated by the SET enunciator on the LCD display.

4.Press and/or hold the or keys to set the desired alarm set point. To change the set point faster, press . This will activate the FAST SET mode which will change the set point 10x faster than normal. Press again to return to the normal speed SET mode.

8

English

REF-METER-OCTA User’s Guide

5.Press . The display will automatically change to zero and the RUN indicator will show to indicate that the program is running.

6.When the applied (or removed) weight exceeds the programmed amount, the alarm will sound and the DONE indicator will flash on the display.

7.Press any key to stop the alarm.

8.To cancel the RUN mode at any time, press the key.

NOTE: The RUN mode can only be initiated from the SET mode. If you cancel the RUN mode by pressing , and wish to RUN again, press (the previous set point will be restored) followed by again. The display will be zeroed when the program restarts. You

may program the SET mode without starting the RUN mode by pressing after setting the program set point. The new value will be saved until next time the SET mode is

activated. can be used during the RUN mode similarly as described in the HOLD MODE section. The REF-METER-OCTA-PLUS provides additional functionality when using the RUN mode. Refer to the REF-METER-OCTA-PLUS User’s Guide for details.

Tank Capacity Mode

It is often convenient to know the relative amount of material (i.e. refrigerant) remaining in a container (tank). The REF-METER-OCTA’s Tank Capacity Mode allows a continuous display of the percentage of material remaining in a tank. In order to compute the percentage accurately, the REF-METER-OCTA must be trained to know the weights of an empty and full tank. To train the REF-METER-OCTA Tank Capacity Mode, perform the following steps:

9

REF-METER-OCTA User’s Guide

English

Tank Capacity Mode Training

1.While holding down, press . The SET TANK indicator will turn on, and OFF will show on the display. This indicates that the Tank Capacity Mode is currently off.

2.Turn the Tank Capacity Mode on by pressing . The display will show ON, and the Alternate Numeric Display and Percent Indicator will turn on.

3.Press to proceed to the first step of training. 0% will flash in the Alternate Numeric Display indicating that the weight of an empty container must be registered.

4.Apply an empty container (or a load representing the weight of an empty container) on the platform. Wait 5 seconds for the load to stabilize, then press . 100% will flash in the Alternate Numeric Display indicating that the weight of a full container must be registered.

5.Apply a full container (or a load representing the weight of a full container) on the platform. Wait 5 seconds for the load to stabilize, then press . This completes the training process, and the SET TANK indicator will turn off.

6.From this point forward, the Alternate Numeric Display will show the percent of material remaining in the container from 0% to 100%.

NOTE: The 100% weight must be larger than the 0% weight by at least 200g. If not, “Err” will show on the Alternate Numeric Display. To clear the error, retrain as above using a 100% weight that is at least 200g larger than the 0% weight. During training, the ZERO key may be used to assist in setting the 0% and 100% values. This will have no effect on the training, as the Tank Capacity Mode relies on absolute, not relative, weights.

10

English

REF-METER-OCTA User’s Guide

Perform the following steps to turn the Tank Capacity Mode Off:

Turning Tank Capacity Mode Off

1.While holding down, press . The SET TANK indicator will turn on, and ON will show on the display. This indicates that the Tank Capacity Mode is currently on.

2.Turn the Tank Capacity Mode off by pressing . The display will show OFF, and the Alternate Numeric Display will turn off.

3.Press to return to normal operation.

The Tank Capacity Mode can be turned back on without retraining. The REF-METER- OCTA will remember the previous 0% and 100% set points until the unit is re-trained as above. To turn the Tank Capacity Mode on without re-training, perform the following steps:

Turning the Tank Capacity Mode On without Re-training

1.While holding down, press . The SET TANK indicator will turn on, and OFF will show on the display. This indicates that the Tank Capacity Mode is currently off.

2.Turn the Tank Capacity Mode on by pressing . The display will show ON, and the Alternate Numeric Display and Percent Indicator will turn on.

3.Press to return to normal operation.

Battery Level Indicator

The battery level indicator shows the relative strength of the batteries. Full power is indicated by four bars. As the batteries are depleted, the number of bars displayed decreases, until no bars are left. At this point, it is necessary to replace the batteries (refer to the Battery Installation section above). If the battery power drops to the point where the REF-METER-OCTA can no longer function accurately, the power will turn off automatically. When the batteries are replaced, and the scale is turned back on, the REF-METER-OCTA will resume operation with all previous setting intact.

11

REF-METER-OCTA User’s Guide

English

Calibration

The REF-METER-OCTA is calibrated at the factory to provide high accuracy. While recalibration should seldom, if ever, be necessary, recalibration is performed easily without sending the product to the manufacturer for service. A known calibration weight (in kilograms) is required to recalibrate the scale, and can be any value between 5 kg and 100 kg. 25 kg is recommend. Best accuracy is obtained by using the largest weight available (i.e. a 50 kg calibration weight will provide better calibration accuracy than a 5 kg calibration weight). In addition, it is necessary to know the weight to within 2 grams.

To recalibrate the REF-METER-OCTA, perform the following steps:

1.Place the REF-METER-OCTA weighing platform on a firm, level surface.

2.Turn the power to the REF-METER-OCTA off.

3.Remove all objects from the platform.

4.While holding , press and release . The REF-METER-OCTA will turn on, and after a few seconds the display will show SET CAL and 25.000 kg.

5.Using or adjust the displayed value (in 1g increments) so that it is equal to the weight of the reference calibration weight. Use the key to adjust in 1 kg increments.

6.Press . A number representing the weight of the unloaded platform will appear on the display. Press to lock in this value. The display will read zero.

7.Apply the calibration weight to the platform. A number representing the applied reference weight will appear on the display. Allow at least 10 seconds for this number to stabilize.

8.Press . The REF-METER-OCTA is now recalibrated to the reference weight.

9.Refer to the Quick Start section above for setting the desired Units and Resolution.

12

English

REF-METER-OCTA User’s Guide

Restoring Factory Calibration

If you make a mistake recalibrating the REF-METER-OCTA, you can always restore the factory calibration (and factory defaults) of the scale.

To restore the factory settings perform the following steps:

1.Turn the power to the REF-METER-OCTA off.

2.Remove any objects from the platform.

3.While holding , press and release . The REF-METER-OCTA will turn on and beep 10 times. The factory settings are now restored.

4.Refer to the Quick Start section above for setting the desired Units and Resolution.

5.Calibrate

Sound

As delivered from the factory, the REF-METER-OCTA beeps when turning on and when keys are pressed. This sound can be muted as follows:

1.Make sure the power is on.

2.While holding , press . The musical symbol on the left of the display will turn off to indicate that the sound has been muted.

Repeat steps 1 and 2 to turn the sound back on.

NOTE: The Mute function only affects the power-on and key-press beeps. It has no effect on the alarm.

13

REF-METER-OCTA User’s Guide

English

HVAC Service

Because of its high stability and accuracy, the REF-METER-OCTA is ideal for automotive, commercial, and residential A/C refrigerant charging and recovery. Its high resolution also allows accurate critical charging of small refrigeration systems such as commercial freezers.

To use the REF-METER-OCTA for refrigerant charging, perform the following steps:

1.Press to set the desired display units.

2.If desired, set up the Tank Capacity Mode as described in the Tank Capacity Mode section. This will allow you to know at any time the percent of refrigerant remaining in the refrigerant cylinder.

3.Carefully set the refrigerant cylinder on the weighing platform.

4.Attach the cylinder to the charging manifold via a utility hose. Open the cylinder valve and purge air from the hose (ie. REFCO CL hoses).

5.Program the desired refrigerant charge weight as described in the Programming section. Activate the program by pressing .

6.Open the manifold valve(s).

7.The display will indicate the weight charged as negative, indicating refrigerant is being removed from the charging cylinder.

8.If the refrigerant cylinder empties while charging:

a.Close all valves.

b.Press to “freeze” the display .

c.Replace the empty refrigerant cylinder with a full one. Attach and purge hoses.

d.Press to exit the Hold Mode.

e.Open manifold valve(s). Charging will continue from where it left off.

9.When charging is complete, the alarm will sound. Close all valves and press any key to cancel the alarm

14

Deutsch

REF-METER-OCTA Bedienungsanleitung

Einleitung

Wir gratulieren Ihnen zum Kauf der digitalen Füllwaage REF-METER-OCTA. Der REF- METER-OCTA ist eine der genauesten Füllwaagen welche am Markt erhältlich sind. Der REF-METER-OCTA verfügt über zusätzliche Funktionen welche heute von keinem anderen Hersteller angeboten werden. Der REF-METER-OCTA ist speziell geeignet für die Kälteund Klimaindustrie auch für sehr kleine Füllmengen von Kältemittel.

Der REF-METER-OCTA ist programmierbar und hat eine integrierte Alarmfunktion welche bei Erreichen der vorgegebenen Füllmenge ein Tonsignal abgibt. Als Option besteht auch die Möglichkeit den REF-METER-OCTA mit dem Zusatzmodul REF-METER-OCTA-PLUS (Magnetventil) als REF-METER-OCTA-KIT aufzurüsten, welches eine automatische Befüllung ermöglicht.

Merkmale

Grosse sehr gut lesbare LCD Anzeige

Masseinheit in Kg, lbs und oz

Speichermöglichkeit

Anzeige der Füllmenge im Kältemittelzylinder

Robustes und kompaktes Design

Geringer Stromverbrauch

Genaue Anzeigeauflösung

Programmierbarkeit

Kalibrierbarkeit

Vorhandenes Gewinde für 10612-REF zum Befüllen von Kältemitteln ab Dosen

Ausbaumöglichkeit zu REF-METER-OCTA-KIT

Technische Daten

Maximalgewicht

100 Kg

Genauigkeit

0.5% der Anzeige

Auflösung

2g

Stromversorgung

4 x 1.5V ‘AAA’ Alkaline Batterien

Batterielebenszeit

30 Std.

Betriebstemperatur

+10°C bis +40°C

Gewicht

2.8 kg

Abmessungen

30.5 cm x 30.5 cm x 4.5 cm

Achtung: Um eine Beschädigung der Waage zu verhindern, das Maximalgewicht nicht überschreiten.

15

REFCO REF-METER-OCTA User Manual

REF-METER-OCTA Bedienungsanleitung Deutsch

Teilediagram

Kältemitteldose

(optional)

LCD Display

10612-REF (optional)

 

Gewinde zum

Tastatur

 

Befestigen des

 

10612-REF

 

Wiegeplattform

Automatischer

 

Staukasten

 

 

Kabeleinzugs-Knopf

 

 

 

Aufhänge-

 

 

bügel

Optischer

 

 

 

 

Empfänger für

 

Laut-

REF-METER-

 

OCTA-PLUS

 

sprecher

 

 

 

Batterie-

 

 

fach

 

Steuergerät Rückseite

16

Deutsch REF-METER-OCTA Bedienungsanleitung

LCD Anzeige

 

 

A

B

 

 

C

E

 

 

 

F

 

 

D

 

 

 

G

 

 

 

H

 

 

 

I

J

K L M N O

P

Item

Funktion

A

Numerische Anzeige

B

Zusatzanzeige

C

Kältmittelzylinder Füllzustandsanzeige in %

D

Masseinheiten

E

Stummschaltung

F

Negativanzeige

G

Batteriezustandsanzeige

H

Anzeige für Schnelleinstellung

I

Speichermodusanzeige

J

Anzeige Füllstandmodus

K

Alarmmodus Ein

L

Haltmodusanzeige

M

Anzeige für Programbeendigung

N

Kalibriermodusanzeige

O

Ventil offen/geschlossen Anzeige bei REF-METER-OCTA-PLUS

P

Auflösungsanzeige

17

REF-METER-OCTA Bedienungsanleitung

Deutsch

Tastatur

Ein / Ausschalter

Auswahl für Masseinheit

Anzeigeauflösungswahl klein, mittel, gross

Nullstellung

Vorwärts/Backlight / Rückwärts bei Programmierung

Schnelleinstellung mit und .

Speicherung der momentanen Anzeige

Programmiermodus

Aktivieren/deaktivieren von Programmierungen

18

Deutsch

REF-METER-OCTA Bedienungsanleitung

Schnellstart

Um den REF-METER-OCTA als einfache Füllwaage zu benützen:

Vorbereitung

1.Den REF-METER-OCTA gemäss der Beschreibung unten auspacken.

2.Installieren der Batterien gemäss Beschreibung unten.

3.Die Waage auf flachen und stabilen Untergrund stellen.

4.REF-METER-OCTA mit Taste einschalten.

5.Masseinheit wählen mit Taste . Es stehen folgende Masseinheiten zur Auswahl: Kilogramm Ö Pfund Ö Pfund und Unzen Ö Unzen

6.Anzeigeauflösung durch Betätigung der Taste gemäss Beschreibung unten auswählen.

Bedienung

1.Stellen Sie eine Kältemittelflasche auf die Wiegeplattform.

2.Durch drücken der Taste die Anzeige auf 0 stellen.

3.Starten Sie den Füllvorgang.

4.Lesen Sie das Gewicht vom Anzeigedisplay ab.

5.Ein Minuszeichen bedeutet Gewichtsabnahme, also das Ausfliessen des Kältemittels aus der Kältemittelflasche beim Füllvorgang. Wenn die gewünschte Einfüllmenge an der Anzeige erreicht wird, den Füllvorgang beenden.

6.Den REF-METER-OCTA durch drücken der Taste ausschalten.

7.Um die Lebensdauer der Batterie zu verlängern schaltet der REF-METER-OCTA nach 30 Minuten Nichtgebrauch automatisch aus. Dies trifft bei einer Vorprogrammierten Füllung nicht zu. Der letzte Anzeigewert wird bei einem Ausschalten automatisch gespeichert und erscheint wieder beim Einschalten.

19

Loading...
+ 49 hidden pages