Refco Gobi II Installation Manual

0 (0)

Universal Condensate Pump

Gobi II

 

 

 

5.5mm

 

 

 

7/32“

PH#2

 

 

 

x 1

x 1

x 1

x 1

x 3

x 3

 

1 (1.5m)

x 1 (1m)

x 3

 

1 (1.5m)

View installation video at www.condensate-pumps.com

1

ON

1

2

ON

1

2

low

up to 18K Btu/h (5.3kW)

ON

1

2

medium low up to 42K Btu/h (12kW)

ON

1

2

medium high up to 72K Btu/h (21.1kW)

ON

1 2

high

up to 120K Btu/h (35kW)

2

1/4˝ (6mm)

Field Supplied

to drain

3

Examples are for

reference only.

www.condensate-pumps.com

Refco Gobi II Installation Manual

4

5

When Indoor Evaporator Unit is powered from the Outdoor Condenser Unit

Evaporator Unit (Indoor)

Condenser Unit (Outdoor)

**Orange:

To use fail-safe operation.

1.Remove the violet wire from indoor live.

2.Connect the orange wire to indoor live.

3.Change alarm relay to fail-safe operation.

L N 3

Violet

**Orange

Grey

Brown

Blue

NC

NO

COM

L

N

 

 

10A Fuse

Replaceable

 

 

NO

 

 

 

 

 

Alarm

 

 

NC

Relay

 

 

 

 

 

Condensate Pump

(typical) Data

3

 

 

 

Earth

 

 

Neutral

N

N

 

100-240vac~

L

L

Alarm Relay Operation Table

Power Up LED Sequence

 

 

Pump Status

Condensate Level

Default

Fail-Safe

Operation

Operation

 

 

Unpowered

N/A

 

 

Powered

Below Alarm Level

 

 

Powered

Alarm-Activated

 

 

**Orange:

To use fail-safe operation.

1.Remove the violet wire from indoor live.

2.Connect the orange wire to indoor live.

3.Change alarm relay to fail-safe operation.

VRF Condenser Unit

 

 

(Outdoor)

 

(typical) Data

 

3

 

 

 

 

Earth

N

N

Neutral

 

L

L

100-240vac~

 

To change Alarm Relay Operation:

1. Unplug pump

2. Move DIP switch positions to 3. Plug pump in

4. Wait for one green LED blink

5. Move DIP switch positions to 6. Wait for one red LED blink

7. Reset DIP switch positions to 8. Wait for one green LED blink

9.Unplug pump

10.Set the DIP switches back to the desired capacity configuration. (Low, Medium-Low, Medium-High, High)

11.Plug Pump in and check that power up LED sequence matches the desired alarm relay operation

12.Done.

To reset default alarm relay operation repeat steps 1 thru 11.

When Multi-Split System is installed

Evaporator Units (Indoor)

3

N

L

 

 

 

 

Safety Circuit

 

 

 

Violet

**Orange

Grey

 

 

NC

NO

COM

Replaceable

10A Fuse

NO

Alarm

COM Relay

Blue N

Brown L

Condensate Pump

View installation video at www.condensate-pumps.com