REFCO REF-METER-OCTA User Manual [en, de, es, fr, it]

REF-METER-OCTA
4679462
Instruction Manual
Electronic Charging scale
Bedienungsanleitung
Elektronische Füllwaage
Mode d’emploi
Appareil de charge électronique
Istruzioni per l’uso
Manual de instrucciones
Báscula eléctrica
English REF-METER-OCTA User’s Guide
Introduction
Thank you for your purchase of the REF-METER-OCTA Digital Charging Scale. The REF­METER-OCTA is the most accurate and precise refrigerant meter available today with features that cannot be found anywhere else. It is ideal for HVAC and Refrigeration service, including Critical Charging of small refrigeration systems.
With the REF-METER-OCTA, you can measure weight in both kgs and lbs units. The REF­METER-OCTA is programmable, and has a built in alarm to indicate a programmed threshold has been exceeded. Attaching the REF-METER-OCTA to the REF-METER­OCTA-PLUS allows automatic refrigerant charging for A/C systems.
Features
Large, high-visibility LCD display
Measures weight in kgs, lbs and oz
Built-in memory remembers all previous settings
Refrigerant Tank Capacity Indicator
Rugged, Compact Design
Long Battery Life
High Accuracy and Resolution
Programmable
Can be calibrated in the field with inexpensive reference weights
Thread for mounting 10612-REF for liquid filling and charging of refrigerants cans
Expandable with REF-METER-OCTA-PLUS
Specifications
Capacity 100 kilograms (220 Pounds) Accuracy 0.5% of Reading +/- 1 Least Significant Digit Resolution 2g, 0.005 lbs., 0.1 oz. Power 4 x 1.5V ‘AAA’ Alkaline Batteries Battery Life 30 hours continuous use Operating Temperature 10C – 40C (50F – 104F) Weight 3.8 kg (6.4 lbs.) Dimensions 30.5 cm x 30.5 cm x 4.5 cm (12.0” x 12.0” x 1.8”)
NOTE: To prevent damage, never exceed the rated capacity of the REF-METER-OCTA.
1
REF-METER-OCTA User’s Guide English
Parts Diagram
10612-REF (optional)
Thread to mount
10612-REF
Weighing
Platform
Button for Cable
auto reel
Mounting
Clip
Speaker
Grill
Battery
Cover
Refrigerant Can (optional)
LCD Display
Keypad
Storage Dock
Optical Port
for REF­METER-
OCTA-PLUS
Control Box Rear View
2
English REF-METER-OCTA User’s Guide
A
LCD Display
B
E
F
G
H
J
I
Item Function
A Main Numeric Display B Alternate Numeric Display C Tank Capacity Percent Indication D Units Indicators E Sound Mute Indicator F “Floating” Negative Indicator (Indicates weight removed from platform) G Battery Level Indicator H Fast Adjustment Indicator
I Set Mode Indicator J Tank Capacity Mode Indicator K Run Mode Indicator L Hold Mode Indicator M Program Complete Indicator N Calibration Mode Indicator O Valve Open/Closed Indicator for use with REF-METER-OCTA-PLUS P Resolution Indicator
3
L
K
O
M
N
P
C
D
REF-METER-OCTA User’s Guide English
Keypad
Press for power-on, press/hold for power off.
Press to cycle through displayed units. Press to select low, medium, or high display resolution. Press to “zero-out” current reading on display.
Use to adjust various settings and programming values/Backlight.
For faster adjustments. Used in conjunction with and . “Freezes” display. Starts programming mode Activates / Deactivates stored program.
4
English REF-METER-OCTA User’s Guide
Quick Start
To operate the REF-METER-OCTA as a basic weigh scale, perform the following steps:
Setup
1. Unpack the scale as described in the “Unpacking the REF-METER-OCTA” section below.
2. Install the batteries into the control box as described in the “Battery Installation” section below.
3. Place the Weighing Platform on a firm, level surface.
4. Turn the REF-METER-OCTA on by pressing
5. Select the proper measurement units by repeated pressing follows:
kilograms Ö pounds Ö pounds and ounces Ö ounces
6. Select the desired display resolution by repeatedly pressing RESOLUTION section.
Basic Weighing Operation
1. If using a container to hold the objects being measured, place it empty on the center of the platform.
2. Press
3. Place the material to measure in the container or on the center of the platform.
4. Read the weight on the display.
5. A positive number indicates the applied weight is greater than the zero value. A
6. Turn the REF-METER-OCTA off by pressing
7. To conserve battery life, the REF-METER-OCTA will turn itself off after 30 minutes of
5
to “zero-out” the scale. The display will read zero.
negative number indicates the applied weight is less than the zero value.
inactivity, unless it is currently running a program (see Programming section). The last state of the REF-METER-OCTA will be restored upon power-up.
.
. The units will cycle as
as described in the
down.
REF-METER-OCTA User’s Guide English
Unpacking the REF-METER-OCTA
1. Remove the REF-METER-OCTA from the carry bag.
2. Push the signed part of the control box to remove it from the storage dock. The storage dock is placed on the low side of the weighing platform.
3. Pull out the control box from the storage dock. When using the REF-METER-OCTA, ensure the cable does not touch the top of the weighing platform to avoid inaccuracies.
4. If desired, extend the mounting hook.
Repacking the REF-METER-OCTA
1. If extended, restore the easel of the control box to the retracted position.
2. Hold the control box and press the yellow auto reel button on the side of the platform.
3. Push the control box firmly into the storage dock of the weighing platform until it snaps in place.
4. Replace the REF-METER-OCTA into the carry bag.
Battery Installation & Replacement
1. Remove the battery cover from the rear of the control box by compressing tab at the base of the battery cover.
2. If necessary, remove old set of batteries.
3. Insert 4 ‘AAA’. Replace battery cover by aligning tabs and snapping back into place.
IMPORTANT: TO PREVENT DAMAGE TO THE REF-METER-OCTA, CAREFULLY OBSERVE BATTERY POLARITY AS MARKED INSIDE THE BATTERY COMPARTMENT. DO NOT LEAVE DEAD BATTERIES INSIDE THE CONTROL BOX. REMOVE BATTERIES IF THE REF-METER-OCTA IS NOT TO BE USED FOR AN EXTENDED PERIOD OF TIME.
6
English REF-METER-OCTA User’s Guide
Resolution
The resolution (minimum incremental weight or volume) that can be displayed by the REF­METER-OCTA can be adjusted to make the display easier to read. Unstable loads or high winds can cause the display to fluctuate erratically. By reducing the display resolution, external influences can be minimized. As shipped, the REF-METER-OCTA is set to MEDIUM resolution, suitable for most purposes. The resolution can be changed to LOW,
MEDIUM or HIGH by repeated pressing resolution for each units mode vs. resolution. Regardless of the resolution setting, the scale operates internally with the highest resolution; therefore, only the displayed value is affected.
7
Resolution Kilograms Pounds
HIGH 2 g
MEDIUM 5 g
LOW 10 g
TABLE 1. Resolution Settings
on the keypad. Table 1 illustrates the displayed
Units
Pounds
&
Ounces
0.005 lbs
0.010
lbs.
0.020
lbs.
Ounces
0.1 oz. 0.1 oz.
0.2 oz. 0.2 oz.
0.5 oz. 0.5 oz.
REF-METER-OCTA User’s Guide English
Over Range Indication
If the weight applied to the weighing platform exceeds the maximum capacity of the REF­METER-OCTA (100 kg), a single “1” will be shown on the left side of the display. To prevent damage to the REF-METER-OCTA, immediately remove the weight from the platform.
Hold Mode
A special feature of the REF-METER-OCTA allows the emptying or replacing bins or containers used for weighing without affecting the weight shown on the display. This Hold Mode may be used as follows:
1. Allow load to settle until display is steady.
2. Press
. The current weight is now locked on the display.
3. Remove, empty, or replace objects, bins, or containers on the platform.
4. Wait 5 seconds for the new load to stabilize.
5. Press
Programming
With the REF-METER-OCTA, a programmable threshold weight will sound an alarm. The alarm will sound when the displayed weight (either positive for increasing weight, or negative for decreasing weight) equals the programmed weight. To program the alarm, perform the following steps:
1. Set up the REF-METER-OCTA with the desired units and resolution as described in the
2. If measuring decreasing weight, place the objects or container with the objects or
3. Press
4. Press and/or hold the or
8
. Measurements will continue from where they left off prior to initiating Hold
Mode.
Quick Start Setup section above.
material that will be removed on the weighing platform.
to start the SET Mode, indicated by the SET enunciator on the LCD display.
keys to set the desired alarm set point. To change the set point faster, press the set point 10x faster than normal. Press
mode.
. This will activate the FAST SET mode which will change
again to return to the normal speed SET
English REF-METER-OCTA User’s Guide
5. Press . The display will automatically change to zero and the RUN indicator will show to indicate that the program is running.
6. When the applied (or removed) weight exceeds the programmed amount, the alarm will sound and the DONE indicator will flash on the display.
7. Press any key to stop the alarm.
8. To cancel the RUN mode at any time, press the
key.
NOTE: The RUN mode can only be initiated from the SET mode. If you cancel the RUN mode by pressing restored) followed by may program the SET mode without starting the RUN mode by pressing
the program set point. The new value will be saved until next time the SET mode is activated.
section. The REF-METER-OCTA-PLUS prov mode. Refer to the REF-METER-OCTA-PLUS User’s Guide for details.
Tank Capacity Mode
It is often convenient to know the relative amount of material (i.e. refrigerant) remaining in a container (tank). The REF-METER-OCTA’s Tank Capacity Mode allows a continuous display of the percentage of material remaining in a tank. In order to compute the percentage accurately, the REF-METER-OCTA must be trained to know the weights of an empty and full tank. To train the REF-METER-OCTA Tank Capacity Mode, perform the following steps:
, and wish to RUN again, press (the previous set point will be
again. The display will be zeroed when the program restarts. You
after setting
can be used during the RUN mode similarly as described in the HOLD MODE
ides additional functionality when using the RUN
9
REF-METER-OCTA User’s Guide English
Tank Capacity Mode Training
1. While holding show on the display. This indicates that the Tank Capacity Mode is currently off.
2. Turn the Tank Capacity Mode on by pressing . The display will show ON, and the Alternate Numeric Display and Percent Indicator will turn on.
3. Press Display indicating that the weight of an empty container must be registered.
down, press . The SET TANK indicator will turn on, and OFF will
to proceed to the first step of training. 0% will flash in the Alternate Numeric
4. Apply an empty container (or a load representing the weight of an empty container) on the platform. Wait 5 seconds for the load to stabilize, then press
the Alternate Numeric Display indicating that the weight of a full container must be registered.
. 100% will flash in
5. Apply a full container (or a load representing the weight of a full container) on the platform. Wait 5 seconds for the load to stabilize, then press
training process, and the SET TANK indicator will turn off.
6. From this point forward, the Alternate Numeric Display will show the percent of material remaining in the container from 0% to 100%.
NOTE: The 100% weight must be larger than the 0% weight by at least 200g. If not, “Err” will show on the Alternate Numeric Display. To clear the error, retrain as above using a 100% weight that is at least 200g larger than the 0% weight. During training, the ZERO key may be used to assist in setting the 0% and 100% values. This will have no effect on the training, as the Tank Capacity Mode relies on absolute, not relative, weights.
. This completes the
10
English REF-METER-OCTA User’s Guide
Perform the following steps to turn the Tank Capacity Mode Off:
Turning Tank Capacity Mode Off
1. While holding show on the display. This indicates that the Tank Capacity Mode is currently on.
2. Turn the Tank Capacity Mode off by pressing Alternate Numeric Display will turn off.
3. Press
The Tank Capacity Mode can be turned back on without retraining. The REF-METER­OCTA will remember the previous 0% and 100% set points until the unit is re-trained as above. To turn the Tank Capacity Mode on without re-training, perform the following steps:
down, press . The SET TANK indicator will turn on, and ON will
to return to normal operation.
Turning the Tank Capacity Mode On without Re-training
1. While holding show on the display. This indicates that the Tank Capacity Mode is currently off.
2. Turn the Tank Capacity Mode on by pressing . The display will show ON, and the Alternate Numeric Display and Percent Indicator will turn on.
3. Press
Battery Level Indicator
The battery level indicator shows the relative strength of the batteries. Full power is indicated by four bars. As the batteries are depleted, the number of bars displayed decreases, until no bars are left. At this point, it is necessary to replace the batteries (refer to the Battery Installation section above). If the battery power drops to the point where the REF-METER-OCTA can no longer function accurately, the power will turn off automatically. When the batteries are replaced, and the scale is turned back on, the REF-METER-OCTA will resume operation with all previous setting intact.
down, press . The SET TANK indicator will turn on, and OFF will
to return to normal operation.
. The display will show OFF, and the
11
REF-METER-OCTA User’s Guide English
Calibration
The REF-METER-OCTA is calibrated at the factory to provide high accuracy. While recalibration should seldom, if ever, be necessary, recalibration is performed easily without sending the product to the manufacturer for service. A known calibration weight (in kilograms) is required to recalibrate the scale, and can be any value between 5 kg and 100 kg. 25 kg is recommend. Best accuracy is obtained by using the largest weight available (i.e. a 50 kg calibration weight will provide better calibration accuracy than a 5 kg calibration weight). In addition, it is necessary to know the weight to within 2 grams.
To recalibrate the REF-METER-OCTA, perform the following steps:
1. Place the REF-METER-OCTA weighing platform on a firm, level surface.
2. Turn the power to the REF-METER-OCTA off.
3. Remove all objects from the platform.
4. While holding after a few seconds the display will show SET CAL and 25.000 kg.
5. Using or weight of the reference calibration weight. Use the
6. Press the display. Press
7. Apply the calibration weight to the platform. A number representing the applied reference weight will appear on the display. Allow at least 10 seconds for this number to stabilize.
8. Press
, press and release . The REF-METER-OCTA will turn on, and
adjust the displayed value (in 1g increments) so that it is equal to the
key to adjust in 1 kg increments.
. A number representing the weight of the unloaded platform will appear on
to lock in this value. The display will read zero.
. The REF-METER-OCTA is now recalibrated to the reference weight.
9. Refer to the Quick Start section above for setting the desired Units and Resolution.
12
English REF-METER-OCTA User’s Guide
Restoring Factory Calibration
If you make a mistake recalibrating the REF-METER-OCTA, you can always restore the factory calibration (and factory defaults) of the scale.
To restore the factory settings perform the following steps:
1. Turn the power to the REF-METER-OCTA off.
2. Remove any objects from the platform.
3. While holding beep 10 times. The factory settings are now restored.
, press and release . The REF-METER-OCTA will turn on and
4. Refer to the Quick Start section above for setting the desired Units and Resolution.
5. Calibrate
Sound
As delivered from the factory, the REF-METER-OCTA beeps when turning on and when keys are pressed. This sound can be muted as follows:
1. Make sure the power is on.
2. While holding
off to indicate that the sound has been muted.
, press . The musical symbol on the left of the display will turn
Repeat steps 1 and 2 to turn the sound back on.
NOTE: The Mute function only affects the power-on and key-press beeps. It has no effect on the alarm.
13
REF-METER-OCTA User’s Guide English
HVAC Service
Because of its high stability and accuracy, the REF-METER-OCTA is ideal for automotive, commercial, and residential A/C refrigerant charging and recovery. Its high resolution also allows accurate critical charging of small refrigeration systems such as commercial freezers.
To use the REF-METER-OCTA for refrigerant charging, perform the following steps:
1. Press
2. If desired, set up the Tank Capacity Mode as described in the Tank Capacity Mode
to set the desired display units.
section. This will allow you to know at any time the percent of refrigerant remaining in the refrigerant cylinder.
3. Carefully set the refrigerant cylinder on the weighing platform.
4. Attach the cylinder to the charging manifold via a utility hose. Open the cylinder valve and purge air from the hose (ie. REFCO CL hoses).
5. Program the desired refrigerant charge weight as described in the Programming section. Activate the program by pressing
.
6. Open the manifold valve(s).
7. The display will indicate the weight charged as negative, indicating refrigerant is being removed from the charging cylinder.
8. If the refrigerant cylinder empties while charging:
a. Close all valves. b. Press
to “freeze” the display .
c. Replace the empty refrigerant cylinder with a full one. Attach and purge hoses. d. Press
to exit the Hold Mode.
e. Open manifold valve(s). Charging will continue from where it left off.
9. When charging is complete, the alarm will sound. Close all valves and press any key to cancel the alarm
14
Deutsch REF-METER-OCTA Bedienungsanleitung
Einleitung
Wir gratulieren Ihnen zum Kauf der digitalen Füllwaage REF-METER-OCTA. Der REF­METER-OCTA ist eine der genauesten Füllwaagen welche am Markt erhältlich sind. Der REF-METER-OCTA verfügt über zusätzliche Funktionen welche heute von keinem anderen Hersteller angeboten werden. Der REF-METER-OCTA ist speziell geeignet für die Kälte­und Klimaindustrie auch für sehr kleine Füllmengen von Kältemittel.
Der REF-METER-OCTA ist programmierbar und hat eine integrierte Alarmfunktion welche bei Erreichen der vorgegebenen Füllmenge ein Tonsignal abgibt. Als Option besteht auch die Möglichkeit den REF-METER-OCTA mit dem Zusatzmodul REF-METER-OCTA-PLUS (Magnetventil) als REF-METER-OCTA-KIT aufzurüsten, welches eine automatische Befüllung ermöglicht.
Merkmale
Grosse sehr gut lesbare LCD Anzeige
Masseinheit in Kg, lbs und oz
Speichermöglichkeit
Anzeige der Füllmenge im Kältemittelzylinder
Robustes und kompaktes Design
Geringer Stromverbrauch
Genaue Anzeigeauflösung
Programmierbarkeit
Kalibrierbarkeit
Vorhandenes Gewinde für 10612-REF zum Befüllen von Kältemitteln ab Dosen
Ausbaumöglichkeit zu REF-METER-OCTA-KIT
Technische Daten
Maximalgewicht 100 Kg Genauigkeit 0.5% der Anzeige Auflösung 2g Stromversorgung 4 x 1.5V ‘AAA’ Alkaline Batterien Batterielebenszeit 30 Std. Betriebstemperatur +10°C bis +40°C Gewicht 2.8 kg Abmessungen 30.5 cm x 30.5 cm x 4.5 cm
Achtung: Um eine Beschädigung der Waage zu verhindern, das Maximalgewicht nicht
überschreiten.
15
REF-METER-OCTA Bedienungsanleitung Deutsch
Teilediagram
10612-REF (optional)
Gewinde zum Befestigen des
10612-REF
Kältemitteldose
(optional)
LCD Display
Tastatur
Wiegeplattform
Automatischer
Kabeleinzugs-Knopf
16
Aufhänge-
bügel
Laut-
sprecher
Batterie-
fach
Staukasten
Steuergerät Rückseite
Optischer Empfänger für REF-METER-
OCTA-PLUS
Deutsch REF-METER-OCTA Bedienungsanleitung
A
LCD Anzeige
B
E
F
G
H
J
I
Item Funktion
A Numerische Anzeige B Zusatzanzeige C Kältmittelzylinder Füllzustandsanzeige in % D Masseinheiten E Stummschaltung
F Negativanzeige G Batteriezustandsanzeige H Anzeige für Schnelleinstellung
I Speichermodusanzeige
J Anzeige Füllstandmodus K Alarmmodus Ein L Haltmodusanzeige M Anzeige für Programbeendigung N Kalibriermodusanzeige O Ventil offen/geschlossen Anzeige bei REF-METER-OCTA-PLUS P Auflösungsanzeige
17
L
K
O
M
N
P
C
D
REF-METER-OCTA Bedienungsanleitung Deutsch
Tastatur
Ein / Ausschalter
Auswahl für Masseinheit Anzeigeauflösungswahl klein, mittel, gross Nullstellung Vorwärts/Backlight / Rückwärts bei Programmierung Schnelleinstellung mit und . Speicherung der momentanen Anzeige Programmiermodus Aktivieren/deaktivieren von Programmierungen
18
Deutsch REF-METER-OCTA Bedienungsanleitung
Schnellstart
Um den REF-METER-OCTA als einfache Füllwaage zu benützen:
Vorbereitung
1. Den REF-METER-OCTA gemäss der Beschreibung unten auspacken.
2. Installieren der Batterien gemäss Beschreibung unten.
3. Die Waage auf flachen und stabilen Untergrund stellen.
4. REF-METER-OCTA mit Taste
5. Masseinheit wählen mit Taste
einschalten.
. Es stehen folgende Masseinheiten zur Auswahl:
Kilogramm Ö Pfund Ö Pfund und Unzen Ö Unzen
6. Anzeigeauflösung durch Betätigung der Taste auswählen.
Bedienung
1. Stellen Sie eine Kältemittelflasche auf die Wiegeplattform.
2. Durch drücken der Taste
die Anzeige auf 0 stellen.
gemäss Beschreibung unten
3. Starten Sie den Füllvorgang.
4. Lesen Sie das Gewicht vom Anzeigedisplay ab.
5. Ein Minuszeichen bedeutet Gewichtsabnahme, also das Ausfliessen des Kältemittels aus der Kältemittelflasche beim Füllvorgang. Wenn die gewünschte Einfüllmenge an der Anzeige erreicht wird, den Füllvorgang beenden.
6. Den REF-METER-OCTA durch drücken der Taste
7. Um die Lebensdauer der Batterie zu verlängern schaltet der REF-METER-OCTA nach 30 Minuten Nichtgebrauch automatisch aus. Dies trifft bei einer Vorprogrammierten Füllung nicht zu. Der letzte Anzeigewert wird bei einem Ausschalten automatisch gespeichert und erscheint wieder beim Einschalten.
ausschalten.
19