Ransburg LEPS5002 User Manual

Ransburg
For MicroPakTM Control Systems
SERVICE MANUAL
CP-98-02.3
(Replaces CP-98-02.2)
April - 2013
POWER SUPPLY
IMPORTANT: Before using this equipment, care­fully read SAFETY PRECAUTIONS, starting on page 1, and all instructions in this manual. Keep this Service Manual for future reference.
Service Manual Price: $30.00 (U.S.)
LEPS5002 Power Supply
NOTE: This manual has been changed from revision CP-98-02.2 to revision CP-98-02.3. Reasons for this change are noted under “Manual Change Summary” inside the back cover of this manual.
Ransburg
CP-98-02.3
Ransburg
CONTENTS
LEPS5002 Power Supply - Contents
PAGE
SAFETY:
SAFETY PRECAUTIONS...........................................................................................................
HAZARDS / SAFEGUARDS......................................................................................................
INTRODUCTION:
GENERAL DESCRIPTION.........................................................................................................
SPECIFICATIONS......................................................................................................................
INSTALLATION:
SYSTEM DIAGRAM (BELLS).....................................................................................................
SYSTEM DIAGRAM (GUNS).....................................................................................................
CONNECTIONS TO THE MICROPAK CONTROL UNIT.........................................................
GROUND CABLE.......................................................................................................................
HIGH VOLTAGE CABLE............................................................................................................
HIGH VOLTAGE CONNECTIONS............................................................................................
COMPONENT IDENTIFICATION..............................................................................................
LOW VOLTAGE CABLE.............................................................................................................
MAINTENANCE:
TROUBLESHOOTING GUIDE...................................................................................................
1-5
1 2-5
6-7
6 7
8-13
8 9 10 10 10-11 12 12 13
14-15
14-15
PARTS IDENTIFICATION:
LEPS5002 POWER SUPPLY - PARTS IDENTIFICATION......................................................
WARRANTY POLICIES:
LIMITED WARRANTY.................................................................................................................
APPENDIX:
PAINT AND SOLVENT SPECIFICATIONS..............................................................................
VISCOSITY CONVERSION CHART.........................................................................................
VOLUMETRIC CONTENT OF HOSE OR TUBE......................................................................
16-17
16-17
18
18
19-22
19 20-21 22
CP-98-02.3
LEPS5002 Power Supply - Safety
SAFETY
Ransburg
SAFETY PRECAUTIONS
Before operating, maintaining or servicing any Ransburg electrostatic coating system, read and understand all of the technical and safety literature for your Ransburg products. This manual contains information that is important for you to know and understand. This information relates to USER SAFETY and PREVENTING EQUIPMENT PROB­LEMS. To help you recognize this information, we use the following symbols. Please pay particular attention to these sections.
A WARNING! states information to alert you to a situation that might cause serious injury if instructions are not followed.
A CAUTION! states information that tells how to prevent damage to equipment or how to avoid a situation that might cause minor injury.
A NOTE is information relevant to the proce­dure in progress.
W A R N I N G
!
The user MUST read and be familiar with the
Safety Secon in this manual and the Ransburg safety literature therein idened.
 This manual MUST be read and thoroughly
understood by ALL personnel who operate, clean or maintain this equipment! Special care should be taken to ensure that the WARNINGS and
safety requirements for operang and servicing
the equipment are followed. The user should be
aware of and adhere to ALL local building and re
codes and ordinances as well as NFPA-33 SAFETY STANDARD, LATEST EDITION, prior to installing,
operang, and/or servicing this equipment.
W A R N I N G
!
While this manual lists standard specications
and service procedures, some minor deviations may be found between this literature and your equipment. Differences in local codes and plant requirements, material delivery requirements, etc., make such variations inevitable. Compare this manual with your system installation draw­ings and appropriate Ransburg equipment man­uals to reconcile such differences.
Careful study and continued use of this manual will provide a better understanding of the equipment and process, resulting in more efcient opera­tion, longer trouble-free service and faster, easier troubleshooting. If you do not have the manuals and safety literature for your Ransburg system, contact your local Ransburg representative or Ransburg.
The hazards shown on the following pages
may occur during the normal use of this equip­ment. Please read the hazard chart beginning on page 2.
1
CP-98-02.3
Ransburg
LEPS5002 Power Supply - Safety
AREA
Tells where hazards may occur.
Spray Area
HAZARD
Tells what the hazard is.
Fire Hazard
Improper or inadequate operation and maintenance
procedures will cause a re
hazard.
Protection against inadver­tent arcing that is capable of
causing re or explosion is
lost if any safety interlocks are disabled during opera­tion. Frequent Power Supply or Controller shutdown indi­cates a problem in the system requiring correction.
SAFEGUARDS
Tells how to avoid the hazard.
Fire extinguishing equipment must be present in
the spray area and tested periodically.
Spray areas must be kept clean to prevent the accumulation of combustible residues.
Smoking must never be allowed in the spray area.
The high voltage supplied to the atomizer must be turned off prior to cleaning, ushing or main­tenance.
When using solvents for cleaning:
Those used for equipment ushing should
have ash points equal to or higher than
those of the coating material.
Those used for general cleaning must have
ash points above 100°F (37.8°C).
Spray booth ventilation must be kept at the rates required by NFPA-33, OSHA, country, and local codes. In addition, ventilation must be main­tained during cleaning operations using am­mable or combustible solvents.
Electrostatic arcing must be prevented. Safe sparking distance must be maintained between the parts being coated and the applicator. A dis­tance of 1 inch for every 10KV of output voltage is required at all times.
Test only in areas free of combustible material. Testing may require high voltage to be on, but only as instructed.
Non-factory replacement parts or unauthor-
ized equipment modications may cause re or
injury.
If used, the key switch bypass is intended for use only during setup operations. Production should never be done with safety interlocks dis­abled.
Never use equipment intended for use in water­borne installations to spray solvent based ma­terials.
The paint process and equipment should be set up and operated in accordance with NFPA­33, NEC, OSHA, local, country, and European Health and Safety Norms.
CP-98-02.3
2
LEPS5002 Power Supply - Safety
Ransburg
AREA
Tells where hazards may occur.
Spray Area
HAZARD
Tells what the hazard is.
Explosion Hazard
Improper or inadequate opera­tion and maintenance proce-
dures will cause a re hazard.
Protection against inadvertent arcing that is capable of caus-
ing re or explosion is lost if
any safety interlocks are dis­abled during operation.
Frequent Power Supply or Controller shutdown indicates a problem in the system requir­ing correction.
SAFEGUARDS
Tells how to avoid the hazard.
Electrostatic arcing must be prevented. Safe sparking distance must be maintained between the parts being coated and the applicator. A dis­tance of 1 inch for every 10KV of output voltage is required at all times.
Unless specically approved for use in hazard­ous locations, all electrical equipment must be located outside Class I or II, Division 1 or 2 hazardous areas, in accordance with NFPA-33.
Test only in areas free of ammable or combus­tible materials.
The current overload sensitivity (if equipped) MUST be set as described in the correspond­ing section of the equipment manual. Protec­tion against inadvertent arcing that is capable
of causing re or explosion is lost if the current
overload sensitivity is not properly set. Fre­quent power supply shutdown indicates a prob­lem in the system which requires correction.
General Use and Maintenance
Improper operation or mainte­nance may create a hazard.
Personnel must be properly trained in the use of this equip­ment.
Always turn the control panel power off prior to
ushing, cleaning, or working on spray system
equipment.
Before turning high voltage on, make sure no objects are within the safe sparking distance.
Ensure that the control panel is interlocked with the ventilation system and conveyor in accor­dance with NFPA-33, EN 50176.
Have re extinguishing equipment readily avail­able and tested periodically.
Personnel must be given training in accordance with the requirements of NFPA-33, EN 60079-0.
Instructions and safety precautions must be read and understood prior to using this equip­ment.
Comply with appropriate local, state, and na­tional codes governing ventilation, re protec­tion, operation maintenance, and housekeep­ing. Reference OSHA, NFPA-33, EN Norms and your insurance company requirements.
3
CP-98-02.3
Ransburg
LEPS5002 Power Supply - Safety
AREA
Tells where hazards may occur.
Spray Area / High Voltage Equipment
HAZARD
Tells what the hazard is.
Electrical Discharge
There is a high voltage device that can induce an electrical charge on ungrounded objects which is capable of igniting coating materials.
Inadequate grounding will cause a spark hazard. A spark can ignite many coating materi­als and cause a re or explo­sion.
SAFEGUARDS
Tells how to avoid the hazard.
Parts being sprayed and operators in the spray area must be properly grounded.
Parts being sprayed must be supported on con­veyors or hangers that are properly grounded. The resistance between the part and earth
ground must not exceed 1 meg ohm. (Refer to
NFPA-33.)
Operators must be grounded. Rubber soled in­sulating shoes should not be worn. Grounding straps on wrists or legs may be used to assure adequate ground contact.
Operators must not be wearing or carrying any ungrounded metal objects.
When using an electrostatic handgun, operators must assure contact with the handle of the ap­plicator via conductive gloves or gloves with the palm section cut out.
NOTE: REFER TO NFPA-33 OR SPECIFIC COUNTRY SAFETY CODES REGARDING PROPER OPERATOR GROUNDING.
All electrically conductive objects in the spray area, with the exception of those objects re­quired by the process to be at high voltage, must
be grounded. Grounded conductive ooring
must be provided in the spray area.
Always turn off the power supply prior to ush­ing, cleaning, or working on spray system equip­ment.
Unless specically approved for use in hazard­ous locations, all electrical equipment must be located outside Class I or II, Division 1 or 2 haz­ardous areas, in accordance with NFPA-33.
CP-98-02.3
4
LEPS5002 Power Supply - Safety
Ransburg
AREA
Tells where hazards may occur.
Electrical Equipment
HAZARD
Tells what the hazard is.
Electrical Discharge
High voltage equipment is uti­lized in the process. Arcing
in the vicinity of ammable or
combustible materials may oc-
cur. Personnel are exposed to
high voltage during operation and maintenance.
Protection against inadvertent
arcing that may cause a re or explosion is lost if safety circuits
are disabled during operation.
Frequent power supply shut­down indicates a problem in the system which requires correc­tion.
An electrical arc can ignite coat-
ing materials and cause a re or explosion.
SAFEGUARDS
Tells how to avoid the hazard.
Unless specically approved for use in hazard­ous locations, the power supply, control cabinet, and all other electrical equipment must be locat­ed outside Class I or II, Division 1 and 2 hazard­ous areas in accordance with NFPA-33 and EN
50176.
Turn the power supply OFF before working on the equipment.
Test only in areas free of ammable or combus­tible material.
Testing may require high voltage to be on, but only as instructed.
Production should never be done with the safety circuits disabled.
Before turning the high voltage on, make sure no objects are within the sparking distance.
Toxic Substances
Spray Area
Certain material may be harmful if inhaled, or if there is contact with the skin.
Explosion Hazard – Incompatible Materials
Halogenated hydrocarbon sol-
vents for example: methylene
chloride and 1,1,1,-Trichloro­ethane are not chemically com­patible with the aluminum that might be used in many system components. The chemical reaction caused by these sol­vents reacting with aluminum can become violent and lead to
an equipment explosion.
Follow the requirements of the Material Safety Data Sheet supplied by coating material manu­facturer.
Adequate exhaust must be provided to keep the air free of accumulations of toxic materials.
Use a mask or respirator whenever there is a chance of inhaling sprayed materials. The mask must be compatible with the material being sprayed and its concentration. Equipment must be as prescribed by an industrial hygienist or
safety expert, and be NIOSH approved.
Aluminum is widely used in other spray ap­plication equipment - such as material pumps, regulators, triggering valves, etc. Halogenated hydrocarbon solvents must never be used with
aluminum equipment during spraying, ushing,
or cleaning. Read the label or data sheet for the material you intend to spray. If in doubt as to whether or not a coating or cleaning material is compatible, contact your coating supplier. Any other type of solvent may be used with aluminum equipment.
5
CP-98-02.3
Ransburg
INTRODUCTION
LEPS5002 Power Supply - Introduction
GENERAL DESCRIPTION
Through the use of integrated cascade technol­ogy, the LEPS5002 High Voltage Power Supply is designed to operate with MicroPakTM rack mounted control systems to generate up to neg-
ative 100,000 Volts DC. The ve high voltage
outputs of the LEPS5002 provide electrostatic
spray applicators with up to a maximum of 1000 microamps current at the maximum voltage of
100kV. This heavy duty source of high voltage provides for rugged, reliable operation in a vari-
ety of industrial nishing applications.
The LEPS5002 Power Supply is similar in func­tion to the single output, dry dielectric model,
part number 74793, with the exception that the
circuits are immersed in oil. This design pro-
vides ve outputs instead of only one, therefore
eliminating the need for a separate junction tank.
use with the Ransburg Aerobell 33TM and Tur­bodisk 33TM rotary atomizers when used in a system that includes:
MicroPak Power Supply Control Unit
SSW-1064, Unshielded Type High Voltage Cable
LKIT0003, High Voltage Connection Kit
LEPS5000-05, Junction Tank
17256-11 (or -12), High Voltage Transfer Switch (Turbodisk 33 only)
The LEPS5002 is also Factory Mutual approved for use with the Ransburg REA IIITM automatic guns when used in a system that includes:
MicroPak Power Supply Control Unit
70393, REA III Automatic Guns
LEPS5000-04, Resistive Junction Tank
The MicroPak Control unit continuously moni­tors the actual high voltage and current outputs, regulates voltage and performs safety diagnos­tics. A low voltage control cable connects the control unit to the LEPS5002 Power Supply. The control unit can be operated from front pan-
el adjustments or from an external PLC.
For information regarding the specications,
installation and operation of the MicroPak Con­trol unit, please refer to the appropriate service manuals or contact your authorized Ransburg representative. Also refer to the MicroPak man­ual for troubleshooting information.
All components of this power supply were se­lected for reliable, heavy duty service. The com­ponents, including the high voltage transformer, operate immersed in high quality (non-pcb) di­electric oil to insulate against corona discharge
and provide excellent heat dissipation of the
internal circuit.
!
C A U T I O N
> The total number of applicators that
can be connected to one power supply is determined by the total power output required for the application. It is recom-
mended that the maximum continuous
output current from the LEPS5002 Power
Supply not exceed 800 microamps.
The LEPS5002 is Factory Mutual approved for
CP-98-02.3
6