Rademacher 35001164 User guide

8. CE Mark and EC Conformity
The present product complies with the requirements of the current European and national directives.
1999/5/EC R&TTE directive
Conformity has been veried. The corresponding declarations and docu­mentation are available on le at the manufacturer’s premises.
9. Warranty conditions
RADEMACHER Geräte-Elektronik GmbH provides a 24-month warranty for new systems that have been installed in compliance with the installation instructions. All construction faults, material defects and manufacturing defects are covered by the warranty.
The following are not covered by the warranty:
◆ Incorrect tting or installation
◆ Non-observance of the installation and operating instructions
◆ Improper operation or wear and tear
◆ External inuences, such as impacts, knocks or weathering
◆ Repairs and modications by third parties, unauthorised persons
◆ Use of unsuitable accessories
◆ Damage caused by unacceptable excess voltage (e.g. lightning)
◆ Operational malfunctions caused by radio frequency overlaps and other such
radio interference
RADEMACHER shall remedy any defects, which occur within the warranty period free of charge either by repair or by replacement of the aected parts or by supply of a new replacement unit or one to the same value. There is no general extension of the original warranty period by delivery of a replacement or by repair as per the terms of the warranty.
Operating and Assembly Manual
DuoFern Switch Adapter Plug 9472
Item No.: 3500 11 64
VBD 595-2 (10.12)
RADEMACHER
Geräte-Elektronik GmbH & Co. KG Buschkamp 7 46414 Rhede (Germany) info@rademacher.de
www.rademacher.de
Service: Hotline 01805 933-171* Fax +49 2872 933-253 service@rademacher.de
* 14 cents / minute from a German xed line network operated by DT AG/ Mobile charges max. 42 cents / minute (applies to Germany only)
Subject to technical modications, misprints and errors. Illustrations not binding.
1. General safety information
4.1 Function table
5. Logging DuoFern transmitters on / o
The use of defective equipment can lead to personal injury and damage to property (elec tric shocks, short circuiting).
Never use defective or damaged equipment. Please contact our Customer Service department in this event .
Incorrect use leads to an increased risk of injury by
STOP
electric shocks or short circuiting.
Children are not permitted to play with the DuoFern Switch Adapter Plug.
Danger from fatal electric shock
DuoFern adapter pl ugs are never full y de-en ergised. Even when the DuoFern adapter plug is switched o, the plugged in electrical appliance is not completely (galvanically) discon­nected from the mains power supply.
Pull the unit from the socket or DuoFern adapter plug before undertaking all work on the electrical appliance.
2. Proper use
Proper use
Only use the DuoFern Switch Adapter Plug for connecting and controlling electrical appliances (e.g. lighting etc.) up to the stated total power level (Technical Specications).
Operating conditions
◆ Only operate the DuoFern Switch Adapter Plug in dry rooms.
◆ Only use with 230 V / 50 Hz mains sockets.
◆ The i nstallation and operation of the DuoFern radio system and its
components (e.g. DuoFern Switch Adapter Plug) is only permitted for those systems and devices where a malfunction in the transmitter or receiver would not cause a danger to personnel or property or where this risk is already covered by other safety equipment.
3. Improper use
Never use the DuoFern radio system and its components (e.g. DuoFern Switch Adapter Plug) for the remote control of devices and systems with height­ened safety-relevant requirements or where there is a heightened risk of accidents. This shall require additional safety equipment. Observe the respective statutory regulations for the installation of such systems.
IMPOR TANT
Do not install the DuoFern Switch Adapter plug outside.
4. Brief description
The DuoFern Swi tch Adapter Plug can be used to integrate and control one electrical appliance (e.g. lighting) within a DuoFern radio network. Man y of th e func tio ns prov ide d by the D uoFe rn tra nsmi tter (e.g. Home Pilot® or D uoFern man ual centr al operati ng unit) ca n t hereby be used.
* WR CongTool with DuoFern central operating unit
RolloTron Comfort DuoFern / Troll Comfort D uoFern
DuoFern standard manual transmitter
DuoFern wall controller
DuoFern radio transmitter, ush-mounted
DuoFern function Value range Factory setting
1. Manual operation on / o -
2. Unit / light mode Unit / light mode Light mode
3. Manual mode on / o on / o O
4. Automatic timer on / o on / o On
5. Random function - -
6. Automatic dawn function - -
7. Automatic dawn function on / o on / o O
8. Automatic dusk function - -
9. Automatic dusk function on / o on / o O
10. Sun function - -
11. Automated solar function on / o on / o O
12. Connectivity test - -
13. Connect with radio code - -
14. Reset via radio (3-stage) - -
15. Single-button operation - -
16. Stairwell function on / o O
17. Stairway time (impulse duration) 100 ms - 3276 s 180 seconds
* The "WR CongTool“ software can be downloaded from our website www.rademacher.de.
4.2 Functional description
The DuoFern Switch Adapter Plug has two switching modes (unit and light
4.2 Functional description
1
mode) with which you can control electrical appliances.
You can switch between the two switching modes using the relevant DuoF­ern transmitter (e.g. HomePilot® etc.). To do so, please read the operating instructions for the respective DuoFern transmitter.
Factory setting = Unit mode
The following table s hows the reactions of the D uoFern Switc h Adapter Plug to the switching commands from a DuoFern trans­mitter:
Reactions of the DuoFern
Switching commands from a DuoFern transmitter*
Adapter Plug in:
Unit mode Light mode
UP ON OFF
STOP OFF OFF
DOWN OFF ON
Automatic dawn function ON OFF
Automatic dusk function OFF ON
Sun function OFF OFF
* e.g. DuoFern standard manual transmitter
2 3
1 On-site button for manual control (On/O) and
status LED
2 Disconnect button
3 Connect button
DuoFern manual central operating unit
DuoFern environmental sensor
● ● ●
● ●
● ●
● ●
● ● ●
● ●
● ● ●
● ●
● ●
● ● ● ●
● ●
● ●
HomePilot®
You must assign every required DuoFern transmitter to the DuoFern Switch Adapter Plug in order that the DuoFern Switch Adapter Plug can be controlled with a DuoFern transmitter. You can assign a maximum of 20 DuoFern transmitters (e.g. HomePilot®; DuoFern manual transmitter standard etc.).
1. Switch the desired DuoFern transmitter to registering mode (please refer to the corresponding operating instructions). Registering mode remains active for 60 seconds.
2. Press either the switch 3 Connect (login)" or the switch 2 "Disconnect (logout)" on the bottom of the DuoFern Switch Adapter Plug.
3. The DuoFern Switch Adapter Plug then transmits either a log-on or log-o signal.
- The status LED ashes green during login.
- The status LED ashes red during logout.
4. If registration is successful, the status LED will light up constantly green for approx. 20 seconds.
5. Log the next DuoFern transmitter on / o. In order to do so, repeat steps 1 to 3.
NOTE
The status LED lights up red if the registration process fails, for example if:
- 20 DuoFern transmitters have already been registered.
- An unsuitable device (e.g. other DuoFern actuator) is registered.
- An attempt was made to log-o a DuoFern transmitter that is not logged-on.
6. Erase data (Reset)
1. Press and hold the "Disconnect button" 2 until the status LED lights
up constantly red.
2. All of the registered DuoFern transmitters are logged-o.
3. Subsequently, the DuoFern Switch Adapter Plug will be reset to its
original supplied state.
7. Technical Specications
Supply voltage: 230 V / 50 Hz
Standby consumption: 0.5 W
Switching capacity: max. 1300 W
Protection class: II (only for use in dry areas)
Frequency: 434.5 MHz
Dimensions (without plug):
- W x H x D: 64 x 106 x 41 mm
Loading...