8. CE Mark and EC Conformity
The present product complies with the requirements of the current
European and national directives.
1999/5/EC R&TTE directive
Conformity has been veried. The corresponding declarations and documentation are available on le at the manufacturer’s premises.
9. Warranty conditions
RADEMACHER Geräte-Elektronik GmbH provides a 24-month warranty for new systems that have been
installed in compliance with the installation instructions. All construction faults, material defects and
manufacturing defects are covered by the warranty.
The following are not covered by the warranty:
◆ Incorrect tting or installation
◆ Non-observance of the installation and operating instructions
◆ Improper operation or wear and tear
◆ External inuences, such as impacts, knocks or weathering
◆ Repairs and modications by third parties, unauthorised persons
◆ Use of unsuitable accessories
◆ Damage caused by unacceptable excess voltage (e.g. lightning)
◆ Operational malfunctions caused by radio frequency overlaps and other such
radio interference
RADEMACHER shall remedy any defects, which occur within the warranty period free of charge either
by repair or by replacement of the aected parts or by supply of a new replacement unit or one to the
same value. There is no general extension of the original warranty period by delivery of a replacement
or by repair as per the terms of the warranty.
Operating and
Assembly Manual
DuoFern Switch Adapter Plug 9472
Item No.: 3500 11 64
VBD 595-2 (10.12)
RADEMACHER
Geräte-Elektronik GmbH & Co. KG
Buschkamp 7
46414 Rhede (Germany)
info@rademacher.de
www.rademacher.de
Service:
Hotline 01805 933-171*
Fax +49 2872 933-253
service@rademacher.de
* 14 cents / minute from a German xed line network operated by DT AG/
Mobile charges max. 42 cents / minute (applies to Germany only)
Subject to technical modications, misprints and errors. Illustrations not binding.

1. General safety information
4.1 Function table
5. Logging DuoFern transmitters on / o
The use of defective equipment can lead to personal
injury and damage to property (elec tric shocks, short
circuiting).
Never use defective or damaged equipment. Please contact
our Customer Service department in this event .
Incorrect use leads to an increased risk of injury by
STOP
electric shocks or short circuiting.
Children are not permitted to play with the DuoFern Switch
Adapter Plug.
Danger from fatal electric shock
DuoFern adapter pl ugs are never full y de-en ergised. Even
when the DuoFern adapter plug is switched o, the plugged
in electrical appliance is not completely (galvanically) disconnected from the mains power supply.
Pull the unit from the socket or DuoFern adapter plug before
undertaking all work on the electrical appliance.
2. Proper use
Proper use
Only use the DuoFern Switch Adapter Plug for connecting and controlling
electrical appliances (e.g. lighting etc.) up to the stated total power level
(Technical Specications).
Operating conditions
◆ Only operate the DuoFern Switch Adapter Plug in dry rooms.
◆ Only use with 230 V / 50 Hz mains sockets.
◆ The i nstallation and operation of the DuoFern radio system and its
components (e.g. DuoFern Switch Adapter Plug) is only permitted for
those systems and devices where a malfunction in the transmitter or
receiver would not cause a danger to personnel or property or where
this risk is already covered by other safety equipment.
3. Improper use
Never use the DuoFern radio system and its components (e.g. DuoFern Switch
Adapter Plug) for the remote control of devices and systems with heightened safety-relevant requirements or where there is a heightened risk of
accidents. This shall require additional safety equipment. Observe the respective
statutory regulations for the installation of such systems.
IMPOR TANT
Do not install the DuoFern Switch Adapter plug outside.
4. Brief description
The DuoFern Swi tch Adapter Plug can be used to integrate and control
one electrical appliance (e.g. lighting) within a DuoFern radio network.
Man y of th e func tio ns prov ide d by the D uoFe rn tra nsmi tter (e.g.
Home Pilot® or D uoFern man ual centr al operati ng unit) ca n t hereby
be used.
* WR CongTool with DuoFern central operating unit
RolloTron Comfort DuoFern / Troll Comfort D uoFern
DuoFern standard manual transmitter
DuoFern wall controller
DuoFern radio transmitter, ush-mounted
DuoFern function Value range Factory setting
1. Manual operation on / o -
2. Unit / light mode Unit / light mode Light mode
3. Manual mode on / o on / o O
4. Automatic timer on / o on / o On
5. Random function - -
6. Automatic dawn function - -
7. Automatic dawn function on / o on / o O
8. Automatic dusk function - -
9. Automatic dusk function on / o on / o O
10. Sun function - -
11. Automated solar function on / o on / o O
12. Connectivity test - -
13. Connect with radio code - -
14. Reset via radio (3-stage) - -
15. Single-button operation - -
16. Stairwell function on / o O
17. Stairway time (impulse duration) 100 ms - 3276 s 180 seconds
* The "WR CongTool“ software can be downloaded from our website www.rademacher.de.
4.2 Functional description
The DuoFern Switch Adapter Plug has two switching modes (unit and light
4.2 Functional description
1
mode) with which you can control electrical appliances.
You can switch between the two switching modes using the relevant DuoFern transmitter (e.g. HomePilot® etc.). To do so, please read the operating
instructions for the respective DuoFern transmitter.
Factory setting = Unit mode
The following table s hows the reactions of the D uoFern Switc h
Adapter Plug to the switching commands from a DuoFern transmitter:
Reactions of the DuoFern
Switching commands from
a DuoFern transmitter*
Adapter Plug in:
Unit mode Light mode
UP ON OFF
STOP OFF OFF
DOWN OFF ON
Automatic dawn function ON OFF
Automatic dusk function OFF ON
Sun function OFF OFF
* e.g. DuoFern standard manual transmitter
2 3
1 On-site button for manual control (On/O) and
status LED
2 Disconnect button
3 Connect button
DuoFern manual central operating unit
DuoFern environmental sensor
● ● ● ● ●
● ● ● ●
● ● ●
● ● ●
● ● ●
● ● ● ●
● ● ●
● ● ● ●
● ● ●
● ●
● ● ●
● ● ● ●
● ● ●
● ●
●
● ● ●
● ●
HomePilot®
You must assign every required DuoFern transmitter to the DuoFern Switch
Adapter Plug in order that the DuoFern Switch Adapter Plug can be controlled with
a DuoFern transmitter. You can assign a maximum of 20 DuoFern transmitters
(e.g. HomePilot®; DuoFern manual transmitter standard etc.).
1. Switch the desired DuoFern transmitter to registering mode (please
refer to the corresponding operating instructions).
Registering mode remains active for 60 seconds.
2. Press either the switch 3 Connect (login)" or the switch 2 "Disconnect
(logout)" on the bottom of the DuoFern Switch Adapter Plug.
3. The DuoFern Switch Adapter Plug then transmits either a log-on or
log-o signal.
- The status LED ashes green during login.
- The status LED ashes red during logout.
4. If registration is successful, the status LED will light up constantly green
for approx. 20 seconds.
5. Log the next DuoFern transmitter on / o. In order to do so, repeat steps
1 to 3.
NOTE
The status LED lights up red if the registration process fails, for example
if:
- 20 DuoFern transmitters have already been registered.
- An unsuitable device (e.g. other DuoFern actuator) is registered.
- An attempt was made to log-o a DuoFern transmitter that is not
logged-on.
6. Erase data (Reset)
1. Press and hold the "Disconnect button" 2 until the status LED lights
up constantly red.
2. All of the registered DuoFern transmitters are logged-o.
3. Subsequently, the DuoFern Switch Adapter Plug will be reset to its
original supplied state.
7. Technical Specications
Supply voltage: 230 V / 50 Hz
Standby consumption: 0.5 W
Switching capacity: max. 1300 W
Protection class: II (only for use in dry areas)
Frequency: 434.5 MHz
Dimensions (without plug):
- W x H x D: 64 x 106 x 41 mm