Rademacher 32480366 User guide

DuoFern Standard manual transmitter Operating instructions .................................................................... 27
EN
Item no. 3248 03 66/3248 03 61
VBD 473-2 (05.13)
Dear customer ...
i
…in purchasing this DuoFern Standard manual transmitter, you have decided on a quality product manufactured by RADEMACHER. We would like to thank you for your condence.
All of our highly qualied sta at RADEMACHER stand behind this product.
These operating instructions…
... describe the installation, the electrical connection and the operation of your manual transmitter. Please read these instructions completely and observe all of the safety instructions before commencing
with the installation. Please keep these instructions in a safe place and include them with the device in the event it changes owners.
The warranty becomes null and void in the event of any damage or loss caused by failure to observe these operating and safety instructions. We accept no liability for any consequential losses or damage resulting from non-observance of these instructions.
2828
EN
i
Contents
EN
Dear customer ... ............................................. 28
General view/Operating elements ..................30
Rear side of device ..........................................31
Key to symbols ................................................32
General safety advice ......................................32
Proper use / operating conditions ...................33
Improper use ...................................................33
Short description of the
DuoFern Standard manual transmitter ............34
Register DuoFern end devices
(applies to item nos. 3248 03 66) .................... 36
Register DuoFern end devices
(applies to item nos. 3248 03 61) .................... 38
Delete DuoFern end devices ............................40
End point setting.............................................41
Reversal of rotational direction .......................43
Activate “purge“ function ................................ 45
Manual operation of actuators with
several channels ..............................................46
Manual operation ...........................................46
Controlling blinds and dimmers in jog mode ..47
Switching jog mode on and o .......................47
Delete settings (Reset) ....................................48
Technical Data .................................................49
Battery change................................................50
CE Mark and EC Conformity .............................51
Warranty conditions ....................................... 52
2929
General view/Operating elements
i
EN
LED-status
green orange
UP (on/o)
STOP (o)
DOWN (on/o)
Device buttons or
group buttons
. . .
Item no.:
3248 03 66
3030
* Switching jog mode
on/o
Item no.:
3248 03 61
Rear side of device
i
Item no.: 3248 03 66 3248 03 61
EN
Space for note
Example of identication plate
for Item no. 3248 03 66
Connect
button
Registering mode
Reversal of rotational direction
Purge function
1 x
2 x
Hold for 5 s
Fixing screw
1 x
2 x
Hold for 5 s
Disconnect button
Disconnect mode
End point setting
Reset
3131
STOP
STOP
Key to symbols
i
This concerns your safety.
Please pay particular attention to and carefully follow all instructions with this symbol.
This symbol advises of malpractices that may cause damage to people and property.
NOTE
NOTE/I MPORTANT/C AUTION
This heading indicates information that is important to the proper functioning of the device.
i
General safety advice
Improper use increases risk of injury.
Children must not be allowed to play with the DuoFern Standard manual transmitter.
Please store the DuoFern Standard manual transmitter in such a way that it cannot unintentionally
be operated by playing children, for example.
3232
EN
Proper use / operating conditions
i
Use the DuoFern Standard manual transmitter only for the remote control of:
Roller shutters
Electrical consumers (e.g. lighting)
Operating conditions
The DuoFern radio system may only be operated with and installed in systems and devices in which transmitter or receiver faults do not present any danger to persons or property or for which these hazards are removed by the use of other safety equipment.
Use the DuoFern Standard manual transmitter only in dry rooms.
i
Improper use
Never use controls with DuoFern radio technology (e. g. RolloTron Comfort DuoFern and DuoFern Standard manual transmitter) for remote operation of devices and equipment with increased safety requirements or increased risk of accident. Additional safety equipment is required to do so. Please observe the relevant legal regulations for setting up such systems.
EN
3333
Short description of the DuoFern Standard manual transmitter
i
The DuoFern wireless system enables bidirectional data exchange between the various participants of a wireless network. All switching commands from a DuoFern transmitter will be conrmed by the DuoFern receivers.
Using the DuoFern Standard manual transmitter you can manually remotely control various DuoFern devices (e. g. RolloTron Comfort/Standard DuoFern or DuoFern actuators for lighting).
Command buttons
With the aid of the three command buttons, UP (on/o )/STOP (o) / DOWN (on/o), see page 30, you can transmit manual switching commands to the registered DuoFern end devices.
Device buttons or group buttons (only for item nos. 3248 03 66)
DuoFern Standard manual transmitter 3248 03 66 has 6 device or group buttons (see page30) which you can allocate to any DuoFern end device (see table on page 35). In this way it is possible to have an individual as well as a group control of various devices (see page 37).
Connect button
You can call up the following functions with the connect button:
Registering mode Register DuoFern end device on manual transmitter.
Reversal of rotational direction. Reverse rotational direction of tubular motor or switchover between
the devices and the lighting function.