Quantum, the Quantum logo, DLT, DLTtape, the DLTtape logo, SuperLoader, Scalar, StorNext, and DXi are registered
trademarks of Quantum Corporation, registered in the U.S. and other countries. All other trademarks are the property of their
respective companies. Specifications are subject to change without notice.
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Purpose of This Release
The Scalar i6K i12.2.2 release details bug fixes described in the Resolved Issues
section.
Visit http://www.quantum.com for additional information about the Scalar
i6000 and prior releases.
New Features and Enhancements
This release contains no new features or enhancements.
General Information
• The standalone LMC client is not provided by default. Contact Quantum
Service for details.
• JRE is not required with the standalone LMC client.
• If media is encrypted on an IBM drive using Library Managed Encryption
(LME), the library will initially report the media as being unencrypted when
it is actually encrypted. The encryption status of the media will be properly
reported once the media is re-mounted in the drive.
• To help maintain system integrity and for marketing purposes, Quantum
regularly collects system information through automatic emails. These
emails contain configuration and status information only, and do not
contain any customer data stored on the system. To disable this function:
1 Log on to your library.
2 Go to Setup > System Setting > Physical Library.
3 In the Send Usage Statistics area, select the Disable radio button.
4 Click OK.
• The Web client places a cookie on the user’s computer to provide the last
user’s credentials upon login. The cookie only collects the user’s credentials
to facilitate login, and does not collect any other user data.
2Purpose of This Release
Security Scanners
Quantum runs the following Security scanners against the library:
• BeyondTrust Retina Network Security Scanner version 5.18.3.2656.
• No critical issues were reported
Compatibility and Support
Encryption Key
Management Drive
Support
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
HP
Encryption Option
Application Managed
Encryption
Q-EKMNot
SKMRequires
KMIP Key Manager
1
- Only SafeNet and Thales encryption key servers are supported KMIP configurations
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Firmware Compatibility
Matrix
The following table shows information on drive and auxiliary firmware
compatibility with this release of Scalar i6000. This information is current as of
this product release. For the most up-to-date information on the latest qualified
firmware, please visit: http://www.quantum.com.
1. For information about installing the LMC remote client, contact Quantum Support.
2. Check with Quantum Support for the latest firmware.
3. Logical serial number addressing (drive spoofing) is not supported.
To view a list of backup software packages that have been tested for
interoperability with the Scalar i6000, refer to the Quantum Software
Compatibility Guide at http://www.quantum.com/swcompguide.aspx.
4Compatibility and Support
Resolved Issues
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
This release of Scalar i6000 firmware resolved the following issues:
Change
Request
Number
560963534826An external application passing a value of
56104After enabling IPv6 and DHCPIPv6 on the
56007Using the stateless auto-configuration IPv6
Service
Request
NumberDescriptionResolution
0 will cause internal library
communications between the RCU and
MCB to fail.
library, a reboot would fail to get a DHCP IP
address.
may not allow a connection to the library’s
LMC, even with IPv6 enabled.
Known Issues
This release of i6000 i12.2.2 firmware has the following known issues.
Fixed.
Fixed.
Fixed.
Change
Request
Number
42325If a SafeNet key server(s) in a cluster is not
43012When the library has an issue importing
Service
Request
Number
DescriptionWorkaround
reachable during normal key requests,
encryption keys issued by other key servers
in the cluster will not automatically
replicate to the unreachable server(s)
afterwards.
encryption keys, an error message
erroneously informs users that there was a
communication issue with the key server.
Users need to sync the key server
cluster manually.
Verify that communication to the key
server is operational (perform Path
Diagnostics).
If communication with the key server
is not impacted, the issue is that the
keys cannot be imported due to
being wrapped with a certificate
(public key) that does not match the
server’s private key.
Resolved Issues5
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Change
Request
Number
Service
Request
Number
DescriptionWorkaround
43149In some instances, during a drive firmware
update and associated drive reboot, a
diagnostic ticket reporting the drive has
been removed may be generated.
50514,
50591
1647282,
1647440
MICA should only inform of multi-initiator
conflicts, not just multi-initiator operation
without reservations.
53329EEB attached IBM LTO-5 and LTO-6 drives
upgraded to latest drive firmware may
come up in the library in passive mode.
51994When a drive sled is added to a partition it
may not appear in RES data.
The drive should come back online
after the firmware update is
complete and the diagnostic ticket
will auto close. If not, follow the
directions on the diagnostic ticket to
troubleshoot.
If multi-initiator operation without
reservations is being reported, you
can filter the diagnostic tickets.
From the GUI, configure the library to
enable diagnostic ticket filtering
(Setup > Notifications > Tickets Filter).
Reboot each drive individually. If that
doesn’t fix the issue, reboot the
library.
Make sure that the robot(s) is
enabled and initialized before
physically adding the drive to the
library.
54091During a backup, if the drive loses both FC
connections, failover will occur but the
media will not be moved to home slot.
51702During IVT, data pertaining to the drive-
side magazines in the right parking
module is not included in the report.
To get the media to return to home
slot from Net back Up (NBU):
1 Select Devices > Robot.
2 Right click.
3 Select Change.
4 Browse to select robot device.
5 Click OK.
6 Click OK.
7 Click OK. Media is then put in it’s
home slot.
Make sure that the calibration targets
are located in the correct column and
row.
If calibration targets cannot be in
their proper position because of drive
location, you can move the drives to
different positions in the drive sled.
6Known Issues
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Change
Request
Number
Service
Request
Number
DescriptionWorkaround
54202If you disconnect the cable from a control
path drive that is connect to a host HBA,
the library will lose connectivity to the
robot.
54220If the control path drive fails over during
an import, any media in the picker will not
be discovered.
54580A Series 3 control module may show the
presence of two CMBs even though there
is only one.
546303948014If the email addresses in the Contact tab
of the Notifications dialog and the Email Notifications dialog are the same, an
email will ‘bounce’ (ie, undeliverable) and
fail to be delivered.
1 Update path to robot.
2 run library audit
checklabel = barcode.
3 Media will now return to its home
slot.
4 Users are now able to run
simultaneous backups to both
drives without repairing FC
connection on Host HBA.
1 Run checkin libvolume search=yes
to pickup missing media
2 Then rerun the checkin libvolume
search=bulk to import remaining
media in I/E.
There is no negative effect to library
functionality. The second CMB listed
is actually the MCB.
Check:
Setup > Notifications > System
Setup (Email Address field), and
Setup > Email Configuration
(Sender Address field)
54852During a change to the internal IP of the
library the GUI can hang if you wait too
long to respond to dialog prompts.
55202When upgrading from i11.x to i12.x, all
ticket suppression filters will not be
restored. Restoring a configuration back to
i11.3 will also not restore the filters.
55216In libraries larger than 8 frames,
a geo-addressing issue may cause
diagnostic tickets related to CMBs and
HDCs to be generated in error.
55492When upgrading from i11.3 to i12.2.1, the
partition is not mapped or listed in the
Access Group Configuration.
Respond to the dialog prompts in a
timely manner. If you do wait too
long, reboot the library.
Before the upgrade, note which
filters you have set and then reset
them after the upgrade is complete.
6-66572-xxScalar Key Manager Safety Information by IBM
6-66535-xxScalar Key Manager Open Source License
Agreement
8Documentation
Contacting Quantum
More information about this product is available on the Service and Support
website at www.quantum.com/support. The Service and Support Website
contains a collection of information, including answers to frequently asked
questions (FAQs). You can also access software, firmware, and drivers through
this site.
For further assistance, or if training is desired, contact Quantum:
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Quantum Technical Assistance
Center in the USA:
For additional contact information:
To open a Service Request:
For the most updated information on Quantum Global Services, please visit:
www.quantum.com/support
+1 800-284-5101
www.quantum.com/support
www.quantum.com/osr
Contacting Quantum9
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
10Contacting Quantum
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.