Quantum Scalar i6000 Release Notes

Quantum Scalar i6000
Release Notes
Product Scalar® i6000, Firmware Version i12.2.2
Firmware Version 710Q.GS11200

Contents

Supported Web Browsers (Java GUI)
Supported Web Browsers (WebGUI)
Required Java Runtime Environment (JRE)
Date June 2015
Purpose of This Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
New Features and Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Microsoft Windows Ubuntu x86/ia64 Red Hat Linux x86/ia64
Firefox Internet Explorer versions 7 and higher
Firefox Chrome
JRE version 6 and higher
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Security Scanners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Compatibility and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Resolved Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Known Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Contacting Quantum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
© 2015 Quantum Corporation. All rights reserved. 6-66883-41 Rev A, June 2015
Quantum, the Quantum logo, DLT, DLTtape, the DLTtape logo, SuperLoader, Scalar, StorNext, and DXi are registered trademarks of Quantum Corporation, registered in the U.S. and other countries. All other trademarks are the property of their respective companies. Specifications are subject to change without notice.
Quantum Scalar i6000 Release Notes 6-66883-41 Rev A June 2015

Purpose of This Release

The Scalar i6K i12.2.2 release details bug fixes described in the Resolved Issues section.
Visit http://www.quantum.com for additional information about the Scalar i6000 and prior releases.

New Features and Enhancements

This release contains no new features or enhancements.

General Information

• The standalone LMC client is not provided by default. Contact Quantum Service for details.
• JRE is not required with the standalone LMC client.
• If media is encrypted on an IBM drive using Library Managed Encryption (LME), the library will initially report the media as being unencrypted when it is actually encrypted. The encryption status of the media will be properly reported once the media is re-mounted in the drive.
• To help maintain system integrity and for marketing purposes, Quantum regularly collects system information through automatic emails. These emails contain configuration and status information only, and do not contain any customer data stored on the system. To disable this function:
1 Log on to your library.
2 Go to Setup > System Setting > Physical Library.
3 In the Send Usage Statistics area, select the Disable radio button.
4 Click OK.
• The Web client places a cookie on the user’s computer to provide the last user’s credentials upon login. The cookie only collects the user’s credentials to facilitate login, and does not collect any other user data.
2 Purpose of This Release

Security Scanners

Quantum runs the following Security scanners against the library:
• BeyondTrust Retina Network Security Scanner version 5.18.3.2656.
• No critical issues were reported

Compatibility and Support

Encryption Key Management Drive Support

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
HP
Encryption Option
Application Managed Encryption
Q-EKM Not
SKM Requires
KMIP Key Manager
1
- Only SafeNet and Thales encryption key servers are supported KMIP configurations
LTO-4
Supported Supported Supported Supported Supported Supported
Supported
EKM License
1
Requires EKM License
IBM LTO-4
Requires EKM License
Not Supported
Not Supported
HP LTO-5
Not Supported
Requires EKM License
Requires EKM License
IBM LTO-5
Requires EKM License
Requires EKM License
Requires EKM License
HP LTO-6
Not Supported
Requires EKM License
Requires EKM License
IBM LTO-6
Requires EKM License
Requires EKM License
Requires EKM License
Security Scanners 3
Quantum Scalar i6000 Release Notes 6-66883-41 Rev A June 2015

Firmware Compatibility Matrix

The following table shows information on drive and auxiliary firmware compatibility with this release of Scalar i6000. This information is current as of this product release. For the most up-to-date information on the latest qualified firmware, please visit: http://www.quantum.com.
Release: i12.2.2
Library Firmware: 710Q.GS11200
Library Management Console (LMC) Remote Client: 710G.GH10600
Drive Types Firmware Version
2
IBM LTO-1 (SCSI) 5AU1
IBM LTO-1 (FC) 5AU1
IBM LTO-2 (SCSI) A4N0
IBM LTO-2 (FC) A4N0
IBM LTO-3 (FC) 2 Gb 93GM
IBM LTO-3 (FC) 4 Gb 93GM
IBM LTO-4 (FC) 4 Gb C7QH

Backup Software Compatibility

IBM LTO-5 (FC) 8 Gb E6Q6
IBM LTO-6 (FC) 8 Gb E6R6
HP LTO-3 (FC) 2 Gb L67Z
HP LTO-3 (FC) 4 Gb M69Z
HP LTO-4 (FC) 4 Gb H64Z
HP LTO-5 (FC) 8 Gb I6GZ
HP LTO-6 (FC) 8 Gb J55Z
1. For information about installing the LMC remote client, contact Quantum Support.
2. Check with Quantum Support for the latest firmware.
3. Logical serial number addressing (drive spoofing) is not supported.
To view a list of backup software packages that have been tested for interoperability with the Scalar i6000, refer to the Quantum Software Compatibility Guide at http://www.quantum.com/swcompguide.aspx.
4 Compatibility and Support

Resolved Issues

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
This release of Scalar i6000 firmware resolved the following issues:
Change Request Number
56096 3534826 An external application passing a value of
56104 After enabling IPv6 and DHCPIPv6 on the
56007 Using the stateless auto-configuration IPv6
Service Request Number Description Resolution
0 will cause internal library communications between the RCU and MCB to fail.
library, a reboot would fail to get a DHCP IP address.
may not allow a connection to the library’s LMC, even with IPv6 enabled.

Known Issues

This release of i6000 i12.2.2 firmware has the following known issues.
Fixed.
Fixed.
Fixed.
Change Request Number
42325 If a SafeNet key server(s) in a cluster is not
43012 When the library has an issue importing
Service Request Number
Description Workaround
reachable during normal key requests, encryption keys issued by other key servers in the cluster will not automatically replicate to the unreachable server(s) afterwards.
encryption keys, an error message erroneously informs users that there was a communication issue with the key server.
Users need to sync the key server cluster manually.
Verify that communication to the key server is operational (perform Path Diagnostics).
If communication with the key server is not impacted, the issue is that the keys cannot be imported due to being wrapped with a certificate (public key) that does not match the server’s private key.
Resolved Issues 5
Quantum Scalar i6000 Release Notes 6-66883-41 Rev A June 2015
Change Request Number
Service Request Number
Description Workaround
43149 In some instances, during a drive firmware
update and associated drive reboot, a diagnostic ticket reporting the drive has been removed may be generated.
50514, 50591
1647282, 1647440
MICA should only inform of multi-initiator conflicts, not just multi-initiator operation without reservations.
53329 EEB attached IBM LTO-5 and LTO-6 drives
upgraded to latest drive firmware may come up in the library in passive mode.
51994 When a drive sled is added to a partition it
may not appear in RES data.
The drive should come back online after the firmware update is complete and the diagnostic ticket will auto close. If not, follow the directions on the diagnostic ticket to troubleshoot.
If multi-initiator operation without reservations is being reported, you can filter the diagnostic tickets.
From the GUI, configure the library to enable diagnostic ticket filtering (Setup > Notifications > Tickets Filter).
Reboot each drive individually. If that doesn’t fix the issue, reboot the library.
Make sure that the robot(s) is enabled and initialized before physically adding the drive to the library.
54091 During a backup, if the drive loses both FC
connections, failover will occur but the media will not be moved to home slot.
51702 During IVT, data pertaining to the drive-
side magazines in the right parking module is not included in the report.
To get the media to return to home slot from Net back Up (NBU):
1 Select Devices > Robot. 2 Right click. 3 Select Change. 4 Browse to select robot device. 5 Click OK. 6 Click OK. 7 Click OK. Media is then put in it’s
home slot.
Make sure that the calibration targets are located in the correct column and row.
If calibration targets cannot be in their proper position because of drive location, you can move the drives to different positions in the drive sled.
6 Known Issues
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Change Request Number
Service Request Number
Description Workaround
54202 If you disconnect the cable from a control
path drive that is connect to a host HBA, the library will lose connectivity to the robot.
54220 If the control path drive fails over during
an import, any media in the picker will not be discovered.
54580 A Series 3 control module may show the
presence of two CMBs even though there is only one.
54630 3948014 If the email addresses in the Contact tab
of the Notifications dialog and the Email Notifications dialog are the same, an email will ‘bounce’ (ie, undeliverable) and fail to be delivered.
1 Update path to robot. 2 run library audit
checklabel = barcode.
3 Media will now return to its home
slot.
4 Users are now able to run
simultaneous backups to both drives without repairing FC connection on Host HBA.
1 Run checkin libvolume search=yes
to pickup missing media
2 Then rerun the checkin libvolume
search=bulk to import remaining media in I/E.
There is no negative effect to library functionality. The second CMB listed is actually the MCB.
Check:
Setup > Notifications > System Setup (Email Address field), and
Setup > Email Configuration
(Sender Address field)
54852 During a change to the internal IP of the
library the GUI can hang if you wait too long to respond to dialog prompts.
55202 When upgrading from i11.x to i12.x, all
ticket suppression filters will not be restored. Restoring a configuration back to i11.3 will also not restore the filters.
55216 In libraries larger than 8 frames,
a geo-addressing issue may cause diagnostic tickets related to CMBs and HDCs to be generated in error.
55492 When upgrading from i11.3 to i12.2.1, the
partition is not mapped or listed in the Access Group Configuration.
Respond to the dialog prompts in a timely manner. If you do wait too long, reboot the library.
Before the upgrade, note which filters you have set and then reset them after the upgrade is complete.
Reboot the library.
1 Go to Setup > SNW Wizard. 2 Click Next. 3 Select Host Access radio button. 4 Click Next. 5 Select Host Access Configuration. 6 Click Next. 7 Select Group. 8 Expand Tree.
Known Issues 7
Quantum Scalar i6000 Release Notes 6-66883-41 Rev A June 2015
Change Request Number
52434 3382082,
54884 3522766 During a library snapshot, the HDC may go
52884 The following Nessus scan result may be
Service Request Number
3399088
Description Workaround
If a open door is detected, the library may report the wrong door as open.
offline.
generated:
Nessus was unable to crash the web
, so this might be a false positive.
server
• Check to ensure that all doors are closed properly.
• Check the lance (small metal piece in door lock) to see if it is damaged. Repair if possible and close door.
Reboot the library.
An i6000 library does not use Apache. This is a false positive.

Documentation

The following documents are currently available for the Scalar i6000.
Document Number Document Title
6-66879-xx Scalar i6000 User’s Guide
6-66882-xx Scalar i6000 Planning Guide
6-01847-xx Quantum Encryption Key Manager User’s Guide
6-01884-xx Quantum Encryption Key Manager Release Notes
6-66532-xx Scalar Key Manager Quick Start Guide
6-66531-xx Scalar Key Manager User’s Guide
6-66572-xx Scalar Key Manager Safety Information by IBM
6-66535-xx Scalar Key Manager Open Source License
Agreement
8 Documentation

Contacting Quantum

More information about this product is available on the Service and Support website at www.quantum.com/support. The Service and Support Website contains a collection of information, including answers to frequently asked questions (FAQs). You can also access software, firmware, and drivers through this site.
For further assistance, or if training is desired, contact Quantum:
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Quantum Technical Assistance Center in the USA:
For additional contact information:
To open a Service Request:
For the most updated information on Quantum Global Services, please visit:
www.quantum.com/support
+1 800-284-5101
www.quantum.com/support
www.quantum.com/osr
Contacting Quantum 9
Quantum Scalar i6000 Release Notes 6-66883-41 Rev A June 2015
10 Contacting Quantum
Loading...